(New article from the Materials manual) |
m (→Apparatus: article construction) |
||
Line 5: | Line 5: | ||
:(a) Appropriate sampling thief. | :(a) Appropriate sampling thief. | ||
− | :(b) One-half in. | + | :(b) One-half in. (12 mm) sample splitter. |
==Procedure== | ==Procedure== | ||
Care shall be exercised in obtaining the sample because the material is subject to segregation. At least three bags should be selected and a sample obtained from each bag by use of an appropriate sampling thief. The sample shall be reduced to approximately one quart (1 liter) by use of a one in. (25 mm) sample splitter, taking care to eliminate loss of tinting compound during the splitting procedure. The sample shall be submitted to the Laboratory in a one quart (1 liter) friction top can accompanied by a properly completed Form T-617 showing the manufacturer's name, the brand name and designation of the material, lot number and net quantity represented. | Care shall be exercised in obtaining the sample because the material is subject to segregation. At least three bags should be selected and a sample obtained from each bag by use of an appropriate sampling thief. The sample shall be reduced to approximately one quart (1 liter) by use of a one in. (25 mm) sample splitter, taking care to eliminate loss of tinting compound during the splitting procedure. The sample shall be submitted to the Laboratory in a one quart (1 liter) friction top can accompanied by a properly completed Form T-617 showing the manufacturer's name, the brand name and designation of the material, lot number and net quantity represented. |
Revision as of 08:36, 11 May 2007
This article establishes procedures for sampling red tinting material for use in Portland cement concrete. It provides the material inspection guidelines for Sec 1056.
Apparatus
- (a) Appropriate sampling thief.
- (b) One-half in. (12 mm) sample splitter.
Procedure
Care shall be exercised in obtaining the sample because the material is subject to segregation. At least three bags should be selected and a sample obtained from each bag by use of an appropriate sampling thief. The sample shall be reduced to approximately one quart (1 liter) by use of a one in. (25 mm) sample splitter, taking care to eliminate loss of tinting compound during the splitting procedure. The sample shall be submitted to the Laboratory in a one quart (1 liter) friction top can accompanied by a properly completed Form T-617 showing the manufacturer's name, the brand name and designation of the material, lot number and net quantity represented.