- 14:48, 26 August 2016 diff hist -13 m 751.6 General Quantities →751.6.1 Index of Quantities: Per BR, minor correction
- 14:21, 26 August 2016 diff hist +30 m 751.40 LFD Widening and Repair →751.40.2.4 Deck Repair and Filled Joints: Per BR, updated links
- 13:41, 26 August 2016 diff hist +88 751.40 LFD Widening and Repair →751.40.2.4 Deck Repair and Filled Joints
- 12:18, 26 August 2016 diff hist -21 m Main Page EPG 907.1
- 12:17, 26 August 2016 diff hist -146 m 907.7 Highway Safety Manual →907.7.2 When is the Highway Safety Manual Used?: Per TS, removed archaic link
- 12:16, 26 August 2016 diff hist +691 907.1 Safety Program Guidelines Per TS, restructured and clarified existing content; new content for safety funds that was previously issued by TP in the most recent STIP Programming Guidance.
- 09:22, 26 August 2016 diff hist +123 m 127.7 Threatened and Endangered Species →127.7.6.4 District Responsibilities: link to JSP
- 09:02, 26 August 2016 diff hist 0 N File:127.7 Tumbling Creek Outflight.wmv current
- 09:02, 26 August 2016 diff hist +42 m 127.7 Threatened and Endangered Species →127.7.2 Process: video upload
- 08:56, 26 August 2016 diff hist +35 m 127.7 Threatened and Endangered Species →127.7.6.3 Process: minor clarification
- 11:19, 25 August 2016 diff hist -468 m Main Page EPG 127.7, EPG 703.2.7
- 11:02, 25 August 2016 diff hist +765 m Category:703 Concrete Masonry Construction →703.2.7 Machine Finishing: Per CM and BR, expanded and clarified guidance for the use of a vibratory screed
- 09:20, 25 August 2016 diff hist 0 N File:127.7.6.1.jpg current
- 09:20, 25 August 2016 diff hist 0 N File:127.7.2.jpg current
- 09:19, 25 August 2016 diff hist +10,965 127.7 Threatened and Endangered Species Per Env'l, updated text to match LPA EPG, clarified several practices, added info on migratory birds
- 14:58, 24 August 2016 diff hist -10 Main Page EPG 401, EPG 460, EPG 606.1, EPG 616.18, EPG 643.2, EPG 231.8, EPG 751.1,
- 14:54, 24 August 2016 diff hist +862 460.3 Plant Inspection →460.3.13 Asphalt Binder Sampling: Per CM, collection of a 3rd pt. can of binder as retained sample is appropriate procedure. If a 3rd party test is needed, it can be performed on retained sample
- 14:42, 24 August 2016 diff hist 0 m 236.7 Negotiation Per RW, updated Form 7.2.12
- 13:57, 24 August 2016 diff hist -139 Category:401 Bituminous Base and Pavement →401.2.3 Job Mix Formula (Sec 401.4): Per CM, guidance brought in line w/ current practice. Contractors allowed flexibility in the field to make bin adjustments provided the specs are satisfied
- 13:46, 24 August 2016 diff hist +326 Category:401 Bituminous Base and Pavement →401.2.8 Quality Assurance (Sec 401.9): Per CM, reflects updates to Sec 401. Includes revision to TSR verbiage, plant setting adjustments by contractor without prior approval, average core results
- 13:34, 24 August 2016 diff hist +344 606.1 Guardrail →606.1.3 Guardrail Systems: Per EPG, removed incidental grading for Type A end terminals so that a separate pay item could be included for prime contractors to bid on projects.
- 13:26, 24 August 2016 diff hist +107 751.6 General Quantities →751.6.1 Index of Quantities: Per BR, Hydro Demolition updates
- 12:49, 24 August 2016 diff hist -2,024 m 643.2 Local Utility Adjustments - Public and Private Per DE, generally updated the article to reflect current practice
- 12:47, 24 August 2016 diff hist +16 m Category:747 Bridge Reports and Layouts →747.1.3.4.1 General Information for All Profile Sheets
- 12:46, 24 August 2016 diff hist +2 m Category:747 Bridge Reports and Layouts →747.1.3.2.3 Additional Information for Grade Separations
- 12:39, 24 August 2016 diff hist +56 m Category:747 Bridge Reports and Layouts updated links
- 12:37, 24 August 2016 diff hist +56 m 751.5 Structural Detailing Guidelines updated links
- 12:36, 24 August 2016 diff hist +144 751.1 Preliminary Design →751.1.2.5 Vertical and Horizontal Clearance: Per BR, Criteria for minimum bridge width expanded in EPG 231.8 to include National Bridge Inventory rating system requirements for bridge width.
- 12:22, 24 August 2016 diff hist +3,549 231.8 Bridge Width Per BR, Criteria for minimum bridge width expanded to include National Bridge Inventory rating system requirements for bridge width
- 12:09, 24 August 2016 diff hist 0 N File:751.13.6.5 section BB.jpg current
- 12:09, 24 August 2016 diff hist 0 N File:751.13.6.5 elevation.jpg current
- 12:09, 24 August 2016 diff hist 0 N File:751.13.6.5 part plan.jpg current
- 12:09, 24 August 2016 diff hist 0 N File:751.13.6.4 finger plate.jpg current
- 12:08, 24 August 2016 diff hist 0 N File:751.13.6.4 part plan of slab.jpg current
- 12:08, 24 August 2016 diff hist 0 N File:751.13.6.3 skewed.jpg current
- 12:08, 24 August 2016 diff hist 0 N File:751.13.6.3 squared.jpg current
- 12:07, 24 August 2016 diff hist +1,742 751.13 Expansion Joint Systems →751.13.6 Finger Plate Expansion Devices: New EPG 751.13.4 shows slab extensions at ends of finger plate expansion devices & additional bars in extension. New barrier curb reinforcement guidance
- 11:20, 24 August 2016 diff hist -567 m 616.18 Construction Inspection Guidelines for Sec 616 →Lighting Requirements (for Sec 616.5): Per CM, deleted pay item 616.2010 WORK ZONE LIGHTING
- 15:05, 22 August 2016 diff hist +1 m Main Page
- 14:41, 19 August 2016 diff hist -42 m 236.8 Relocation Assistance Program Per RW, updated link to Replacement Housing Claim form
- 13:55, 19 August 2016 diff hist -1 m Main Page
- 13:55, 19 August 2016 diff hist +89 m Main Page EPG 110.3
- 12:56, 19 August 2016 diff hist 0 N File:110.3 letter 4.doc current
- 12:55, 19 August 2016 diff hist 0 N File:110.3 letter 3.doc current
- 12:55, 19 August 2016 diff hist 0 N File:110.3 letter 2.doc current
- 12:55, 19 August 2016 diff hist 0 N File:110.3 letter 1.doc current
- 12:55, 19 August 2016 diff hist +1,461 m Category:110 State and Federal Wage Rates and Other Requirements →Application of Prevailing Wage off of the Worksite: Per CM, new guidance to address late final plans paperwork from contractor.
- 09:24, 18 August 2016 diff hist 0 m 903.6 Warning Signs →Table 903.6.3 Warning Sign and Plaque Sizes: Per TS, corrected the mistaken sizes of the W16-7P
- 08:01, 17 August 2016 diff hist -5 m 643.4 Railroads Per Multimodal, updated BNSF link
- 14:05, 16 August 2016 diff hist 0 N File:Main Page August 16, 2016.jpg current