Difference between revisions of "1047.9 Laboratory Testing Guidelines for Sec 1047"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (→‎1047.6.2 Sample Record: minor clarification)
m (updated link)
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
This article establish procedures for laboratory testing and reporting samples of corrugated polyethylene culvert pipe. Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1047.pdf Sec 1047] for MoDOT’s specifications.  
+
This article establish procedures for laboratory testing and reporting samples of corrugated polyethylene culvert pipe. Refer to [https://www.modot.org/missouri-standard-specifications-highway-construction Sec 1047] for MoDOT’s specifications.  
  
==1047.6.1 Procedure==
+
==1047.9.1 Procedure==
 
Tests consist of workmanship, pipe dimensions, pipe stiffness, pipe flattening, brittleness, and environmental stress cracking. All tests shall be conducted in accordance with AASHTO M 294.
 
Tests consist of workmanship, pipe dimensions, pipe stiffness, pipe flattening, brittleness, and environmental stress cracking. All tests shall be conducted in accordance with AASHTO M 294.
  
==1047.6.2 Sample Record==
+
==1047.9.2 Sample Record==
The sample record shall be completed in SiteManager, as described in [http://wwwi/intranet/cm/materials/vol_3/AS3510.pdf Automation Section 3510], and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in [[106.9 Reporting Test Results|EPG 106.9 Reporting Test Results]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
+
The sample record shall be completed in SiteManager, as described in [[:Category:101 Standard Forms#Sample Record General Information| Sample Record General Information]] [[image:bulldozer.jpg|20px]], and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
  
 
[[Category:1047 Corrugated Polyethylene Culvert Pipe]]
 
[[Category:1047 Corrugated Polyethylene Culvert Pipe]]

Revision as of 12:57, 17 October 2018

This article establish procedures for laboratory testing and reporting samples of corrugated polyethylene culvert pipe. Refer to Sec 1047 for MoDOT’s specifications.

1047.9.1 Procedure

Tests consist of workmanship, pipe dimensions, pipe stiffness, pipe flattening, brittleness, and environmental stress cracking. All tests shall be conducted in accordance with AASHTO M 294.

1047.9.2 Sample Record

The sample record shall be completed in SiteManager, as described in Sample Record General Information Bulldozer.jpg, and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.