Difference between revisions of "1049.4 Laboratory Testing Guidelines for Sec 1049"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (Corrected link.)
m (→‎1049.4.2 Sample Record: minor clarification)
Line 7: Line 7:
 
==1049.4.2 Sample Record==
 
==1049.4.2 Sample Record==
  
All sample records shall be completed in SiteManager, as described in [http://wwwi/intranet/cm/materials/vol_3/AS3510.pdf Automation Section 3510]. Test results shall be reported on the appropriate templates under the Tests tab. Compression test results for concrete cylinders shall include the notation in remarks, "Specimens submitted for compressive strength at the age indicated." Compression test results for concrete cores shall include the notation in remarks, "Sample submitted for the determinations indicated." Absorption test results for concrete cores or pieces from the wall of the section shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.9 Reporting Test Results|106.9 Reporting Test Results]], are to be included in the remarks to clarify conditions of acceptance or rejection.
+
All sample records shall be completed in SiteManager, as described in [http://wwwi/intranet/cm/materials/vol_3/AS3510.pdf Automation Section 3510]. Test results shall be reported on the appropriate templates under the Tests tab. Compression test results for concrete cylinders shall include the notation in remarks, "Specimens submitted for compressive strength at the age indicated." Compression test results for concrete cores shall include the notation in remarks, "Sample submitted for the determinations indicated." Absorption test results for concrete cores or pieces from the wall of the section shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.9 Reporting Test Results|EPG 106.9 Reporting Test Results]], are to be included in the remarks to clarify conditions of acceptance or rejection.
  
 
[[Category:1049 Precast Concrete Box Culverts]]
 
[[Category:1049 Precast Concrete Box Culverts]]

Revision as of 08:16, 31 March 2010

This article establishes procedures for Laboratory testing and reporting samples of precast concrete box culverts. Refer to Sec 1049 for MoDOT’s specifications.

1049.4.1 Procedure

Compression Test. Samples may consist of two standard concrete cylinders made in accordance with AASHTO T23 or one core drilled from the wall of the section in accordance with AASHTO T280.

1049.4.2 Sample Record

All sample records shall be completed in SiteManager, as described in Automation Section 3510. Test results shall be reported on the appropriate templates under the Tests tab. Compression test results for concrete cylinders shall include the notation in remarks, "Specimens submitted for compressive strength at the age indicated." Compression test results for concrete cores shall include the notation in remarks, "Sample submitted for the determinations indicated." Absorption test results for concrete cores or pieces from the wall of the section shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.9 Reporting Test Results, are to be included in the remarks to clarify conditions of acceptance or rejection.