616.10 Product Requirements for Temporary Traffic Control Devices, Pavement Marking and Delineation

From Engineering_Policy_Guide
Revision as of 10:36, 30 June 2010 by Smithk (talk | contribs) (Per CM and Traffic, former EPG 106.17 moved to EPG 616.27.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

1) Contractor or manufacturer shall provide a letter of certification stating the device is crashworthy.

2) Contractor or manufacturer shall provide a copy of the FHWA acceptance letter for the device as proof of crashworthiness and a letter certifying the device has essentially the same chemistry, mechanical properties and geometry as that submitted for acceptance.

3) Contractor or manufacturer shall provide a letter of certification stating the device meets MoDOT specifications and standards. Certifications shall identify specific sheeting products used in fabrication of the item.

4) Qualified lists direct which products have been found acceptable for use on MoDOT projects and is not an inclusive listing. Products not listed may be found acceptable for use based on certification.

Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
- - - REFLECTIVE SHEETINGS FOR DELINEATORS 1042 - - - - - X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements
- - - REFLECTIVE SHEETINGS FOR TTCD 1063 - - - - - X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements
606 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
606-30.17 1.00 EACH TYPE C CRASHWORTHY END TERMINAL 606, 1040 - - 3 - X X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements, description is at EPG 1040.4.
606-XX.XX 1.00 EACH WATER-FILLED END TREATMENTS - - - 3 - X - - Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements.
606-66.4X 1.00 EACH GUARDRAIL DELINEATOR 606, 1065,1042 606 - - - - X - -
606-66.4X 1.00 EACH GUARD CABLE DELINEATOR 606, 1065,1042 606 - - - - X - -
612 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
612-20.XX 1.00 EACH IMPACT ATTENUATOR 612, 1005,1063 612 - 3 - X X X Qualified List is located in EPG 106.1 Source of Supply and Quality Requirements, description is at EPG 1040.4.
612-30.00 1.00 EACH TRUCK-MOUNTED ATTENUATOR 612, 1063 - - 3 - X X - -
616 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
616-10.05 1.00 SQ.FT. CONSTRUCTION SIGNS 616, 1063 616 - - - - X - -
U-CHANNEL POST, 3 LB 616, 903 616,903 - - - - X - Galvanization is not required.
WOOD POST, X IN. BY X IN. 616, 903 616,903 - - - - X - -
PERFORATED SQUARE STEEL TUBE POST AND ANCHOR SLEEVE 616, 903 616,903 - - - - X - Galvanization is not required.
TYPE 1 PORTABLE 616 616 - 2 - X X - Sign substrate used should be consistent with the acceptance and certification letter.
TYPE 2 PORTABLE 616 616 - 2 - X X - Sign substrate used should be consistent with the acceptance and certification letter.
616-10.07 1.00 EACH SPEED LIMIT AND STROBE LIGHT ASSEMBLY 616, 1063 616 - - - - X - -
616-10.08 1.00 EACH ADVANCED WARNING RAIL SYSTEM 616, 1063 616 - - - - X - -
616-10.09 1.00 EACH FLAG ASSEMBLY 616, 1063 616 - - - - X - -
616-10.20 1.00 EACH CHANNELIZER (DRUM-LIKE) 616, 1063 616 - 1 X - X - -
616-10.21 1.00 EACH CHANNELIZER (DRUM-LIKE) W/LIGHT 616, 1063 616 - 1 X - X - -
616-10.25 1.00 EACH CHANNELIZER (TRIM-LIKE) 616, 1063 616 - 1 X - X - -
CHANNELIZER (CONES) 616, 1063 616 - 1 X - X - -
616-10.30 1.00 EACH TYPE III MOVEABLE BARRICADE 616, 1063 616 - 2 - X X - -
616-10.30 1.00 EACH TYPE III MOVEABLE BARRICADE W/LIGHT AND/OR SIGN 616, 1063 616 - 2 - X X - -
616-10.33 1.00 EACH DIRECTIONAL INDICATOR BARRICADE 616, 1063 616 - 2 - X X - -
616-10.34 1.00 EACH DIRECTIONAL INDICATOR BARRICADE W/LIGHT 616, 1063 616 - 2 - X X - -
616-10.40 1.00 EACH FLASHING ARROW PANEL 616, 1063 616 - 4 - - X - -
616-10.47 1.00 EACH TYPE III OBJECT MARKER 616, 1063 616 - - - - X - -
616-10.51 1.00 EACH WARNING LIGHT, TYPE A 616 616 - - - - X - -
616-10.52 1.00 EACH WARNING LIGHT, TYPE B 616 616 - - - - X - -
616-10.53 1.00 EACH WARNING LIGHT, TYPE C 616 616 - - - - X - -
616-10.70 1.00 EACH TUBULAR MARKER 616, 1063 616 - 1 X - X - -
616-10.95 1.00 EACH RADAR SPEED ADVISORY SYSTEM 616, 1063 - - 4 - - X - -
616-10.98 1.00 EACH CHANGEABLE MESSAGE SIGN 616, 1063 616 - 4 - - X - -
616-11.00 1.00 EACH CHANGEABLE MESSAGE SIGN, CONTRACTOR FURNISHED,COMMISSION RETAINED 616, 1063 616 - 4 - - X X -
616-20.00 1.00 EACH WORK ZONE TRAFFIC SIGNALS (PORTABLE OR TEMPORARY SPAN) 616, 1063 - - 4 for trailer - - X - -
616-20.10 1.00 LUMP SUM WORK ZONE LIGHTING 616 - - 4 for trailer - - X - Lighting Plans are Required
VERTICAL PANELS - - - 2 - X - - Experimental Basis
617 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
617-36.XX 1.00 LINEAR FT TEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/RETAINED (ALL COMBINATIONS) 617, 1064, 1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-36.XX 1.00 LINEAR FT TEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/COMMISSION RETAINED (ALL COMBINATIONS) 617, 1064, 1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-40.00 1.00 EACH TEMPORARY CONCRETE BARRIER HEIGHT TRANSITION 617, 1064,1065 617 - 3 - - X - Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
617-80.0X 1.00 EACH TRAFFIC BARRIER DELINEATOR 617, 1065,1042 617 - - - - X - -
617-XX.XX - - WATER FILLED BARRIER - - - 3 - X - - -
617-XX.XX - - TEMPORARY GLARE SCREENS - - - - - - - - -
620 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
620-XX.XX 1.00 LINEAR FT OR EACH TYPE 1 PREFORMED TAPE 620, 1048 620 - - - - X X -
620-51.XX 1.00 LINEAR FT OR EACH TYPE 2 PREFORMED TAPE 620, 1048 620 - - - - X X -
620-53.XX 1.00 LINEAR FT PREFORMED REMOVABLE MARKING TAPE 620, 1048 620 - - - - X X -
620-53.XX 1.00 LINEAR FT OR EACH PREFORMED SHORT TERM MARKING TAPE 620, 1048 620 - - - - X X -
620-59.XX 1.00 LINEAR FT HIGH BUILD ACRYLIC WATERBORNE PAVEMENT MARKING PAINT 620, 1048 620 - - - - X X -
620-6X.XX 1.00 LINEAR FT OR EACH ACRYLIC WATERBORNE PAVEMENT MARKING PAINT 620, 1048 620 - - - - X X Being phased out due to the use of high build acrylic waterborne pavement marking paint.
620-6X.XX 1.00 LINEAR FT OR EACH ACRYLIC COPOLYMER FAST DRY PAVEMENT MARKING PAINT 620, 1048 620 - - - - X X -
620-62.XX 1.00 LINEAR FT OR EACH TYPE A EPOXY PAVEMENT MARKING 620, 1048 620 - - - - X X -
620-63.XX 1.00 LINEAR FT OR EACH TYPE B EPOXY PAVEMENT MARKING 620, 1048 620 - - - - X X -
620-80.64 1.00 EACH TEMPORARY RAISED PAVEMENT MARKER, TYPE 1 620, 1048 620 - - - - X X -
620-80.65 1.00 EACH TEMPORARY RAISED PAVEMENT MARKER, TYPE 2 620, 1048 620 - - - - X X -
DROP-ON GLASS BEADS 620, 1048 - - - - - X X -
CURB SYSTEMS - - - 2 - X - - -
902 Items
Item No. Unit Type Item Description Sec Std. Plan JSP NCHRP 350 TL-3 Category Number Certification Requirements Qual. List (4) Comments
Crashworthiness (1) FHWA Acceptance Letter (2) Spec and Stnd (3)
902-94.12 1.00 EACH WORK ZONE TRAFFIC SIGNALS (PORTABLE), CONTRACTOR FURNISHED, COMMISSION RETAINED 616, 1063 - - 4 - - X X -


106.17.jpg