Line 1: Line 1:
This article establishes procedures for inspection, acceptance and reporting of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures and latex emulsion admixtures for use in Portland cement concrete. Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1054.pdf Sec 1054] for MoDOT’s specifications.
+
{|style="padding: 0.3em; margin-left:1px; border:2px solid #a9a9a9; text-align:center; font-size: 95%; background:#f5f5f5" width="280px" align="right"
 +
|-
 +
|'''Forms'''
 +
|-
 +
|[https://www.modot.org/sites/default/files/documents/construction_and_materials/material_qualified_product_listing/gs013f2.pdf GS-13 Form 2]
 +
|-
 +
|[https://www.modot.org/sites/default/files/documents/construction_and_materials/material_qualified_product_listing/gs013f3.pdf GS-13 Form 3]
 +
|-
 +
|'''MGS Information'''
 +
|-
 +
|[https://www.modot.org/general-services-specifications-mgs-subject Current General Services Specifications (MGS) By Subject]
 +
|}
  
For Laboratory testing and sample reporting procedures, refer to [[1054.3 Laboratory Testing Guidelines for Sec 1054|1054.3 Laboratory Testing Guidelines for Sec 1054]].
+
This article establishes procedures for inspection, acceptance and reporting of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures and latex emulsion admixtures for use in Portland cement concrete.  Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1054] for MoDOT’s specifications.
 +
 
 +
For Laboratory testing and sample reporting procedures, refer to [[1054.3 Laboratory Testing Guidelines for Sec 1054|EPG 1054.3 Laboratory Testing Guidelines for Sec 1054]].
  
 
==1054.1 Apparatus==
 
==1054.1 Apparatus==
Line 12: Line 25:
  
 
===1054.2.1 Pre-Acceptance Lists===
 
===1054.2.1 Pre-Acceptance Lists===
Manufacturers and Brand Names of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures, latex emulsion admixtures and high range water-reducing admixtures will be placed on the Pre-Acceptance List maintained by the State Construction and Materials Engineer in accordance with 1054.2.2 Manufacturer and Brand Name Approval and the applicable specification. These lists are found in [http://www.modot.mo.gov/business/materials/pdf/PAL/concrete%20admixtures.pdf Concrete Admixtures Pre-Acceptance List] and on MoDOT’s web site.  
+
Manufacturers and Brand Names of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures, latex emulsion admixtures and high range water-reducing admixtures will be placed on the Pre-Acceptance List maintained by the State Construction and Materials Engineer in accordance with 1054.2.2 Manufacturer and Brand Name Approval and the applicable specification. These lists are found in [https://www.modot.org/modot-pal-material-categories Concrete Admixtures Pre-Acceptance List] and on MoDOT’s web site.  
  
 
High range water-reducing admixtures are permitted only when specified in the contract.
 
High range water-reducing admixtures are permitted only when specified in the contract.
Line 20: Line 33:
  
 
===1054.2.3 Basis of Acceptance===
 
===1054.2.3 Basis of Acceptance===
Material is accepted by the PAL criteria as indicated in [[106.2 Pre-Acceptance Lists (PAL)| 106.2 Pre-Acceptance Lists (PAL)]]. The State Construction and Materials Engineer will retain the original certification and guarantee. Additional certification is not necessary if the manufacturer and brand of material is clearly identified on the container or the documentation included with bulk shipments.
+
Material is accepted by the PAL criteria as indicated in [[106.12 Pre-Acceptance Lists (PAL)|EPG 106.12 Pre-Acceptance Lists (PAL)]]. The State Construction and Materials Engineer will retain the original certification and guarantee. Additional certification is not necessary if the manufacturer and brand of material is clearly identified on the container or the documentation included with bulk shipments.
  
 
===1054.2.4 Sampling===
 
===1054.2.4 Sampling===
  
 
====1054.2.4.1 Manufacturing Facility====
 
====1054.2.4.1 Manufacturing Facility====
Each admixture producer will be assigned to a district office for Facility Review, Sampling and Testing in accordance with [[106.2 Pre-Acceptance Lists (PAL)| 106.2 Pre-Acceptance Lists (PAL)]]. During the visit, samples of material available at the facility should be obtained. Materials selected for sampling will tpically be those that have been used in MoDOT work during the past month. Material originating at locations too far from the assigned district’s office is subject to sampling at an intermediate location or at the job site. It is the assigned district’s responsibility to verify with the supplier that the location seleted for sampling is acceptable to the supplier as a location from which a valid PAL source sample may be obtained.
+
Each admixture producer will be assigned to a district office for Facility Review, Sampling and Testing in accordance with [[106.12 Pre-Acceptance Lists (PAL)|EPG 106.12 Pre-Acceptance Lists (PAL)]]. During the visit, samples of material available at the facility should be obtained. Materials selected for sampling will tpically be those that have been used in MoDOT work during the past month. Material originating at locations too far from the assigned district’s office is subject to sampling at an intermediate location or at the job site. It is the assigned district’s responsibility to verify with the supplier that the location seleted for sampling is acceptable to the supplier as a location from which a valid PAL source sample may be obtained.
  
 
====1054.2.4.2 Mixing Facility====
 
====1054.2.4.2 Mixing Facility====
Line 31: Line 44:
  
 
====1054.2.4.3 Sample====
 
====1054.2.4.3 Sample====
A sample of air-entraining admixture, water-reducing admixture, or retarding admixture shall consist of one quart (1 liter) of material in a screw top can. A sample of accelerating admixture or latex emulsion admixture shall consist of one gallon (4 liters) of material in a plastic container. All samples shall be obtained by the manufacturer or contractor’s agent in accordance with the manufacturer’s sampling instructions. The inspector will observe the sampling process. The sample shall be recorded through SiteManager showing the manufacturer's name, the brand name and designation of the material, lot number, net quantity represented, and the location where the sample was obtained using the Sampled From and Sample Origin fields of SiteManager. The Other tab is also used for a Mixing Facility. The PAL ID number obtained by the supplier or mixing facility in accordance with 1054.2.5 Sample Record should be recorded in SiteManager in the “Link To” field.
+
A sample of air-entraining admixture, water-reducing admixture, or retarding admixture shall consist of one quart (1 liter) of material in a plastic wide-mouth bottle. A sample of accelerating admixture or latex emulsion admixture shall consist of one gallon (4 liters) of material in a plastic container. All samples shall be obtained by the manufacturer or contractor’s agent in accordance with the manufacturer’s sampling instructions. The inspector will observe the sampling process. The sample shall be recorded through AASHTOWARE Project (AWP) showing the manufacturer's name, the brand name and designation of the material, lot number, net quantity represented, and the location where the sample was obtained using the Sampled From and Sample Origin fields of AWP. The Other tab is also used for a Mixing Facility. The PAL ID number obtained by the supplier or mixing facility in accordance with EPG 1054.2.5 Sample Record should be recorded in AWP in the “Link To” field.
  
 
===1054.2.5 Sample Record===
 
===1054.2.5 Sample Record===
  
Test results on random samples of admixtures shall be reported by the Laboratory in accordance with 1054.3 Laboratory Testing Guidelines for Sec 1054 and [[106.2 Pre-Acceptance Lists (PAL)| 106.2 Pre-Acceptance Lists (PAL)]].
+
Test results on random samples of admixtures shall be reported by the Laboratory in accordance with [[1054.3 Laboratory Testing Guidelines for Sec 1054|EPG 1054.3 Laboratory Testing Guidelines for Sec 1054]] and [[106.12 Pre-Acceptance Lists (PAL)|EPG 106.12 Pre-Acceptance Lists (PAL)]].
 
 
For material shipped directly to a job site by a supplier, the supplier shall notify the State Construction and Materials Engineer prior to shipment using [[GS13Form3]]. When the material is shipped to a mixing facility, that facility shall notify the State Construction and Materials Engineer of its arrival using [[GS13F2]]. When complete and correct information on the shipment is provided to the State Construction and Materials Engineer, a PAL ID number will be assigned to the material. That number shall be attached to the material container, or be immediately available at the plant, until the material is consumed. The proportioning plant inspector shall continue to show on the daily reports the information required by the [[:Category:500 RIGID PAVEMENT|Construction Inspection Guidelines in the Engineering PolicyGuide’s Rigid Pavement articles]].
 
 
 
Material purchased for maintenance work may be accepted solely on the basis of the manufacturer and brand being on the Pre-Acceptance List. District Materials will report the receipt and acceptance of the material in SiteManager and will mark the containers with the sample ID number they assign.
 
 
 
==1054.3 Laboratory Testing Guidelines for Sec 1054==
 
 
 
This article establishes procedures for Laboratory testing, approving and reporting of admixtures intended for use in portland cement concrete. Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1054.pdf Sec 1054] for MoDOT’s specifications.
 
 
 
===1054.3.1 Procedure===
 
Laboratory prequalification of an admixture will be based on the following procedure:
 
:(a) The manufacturer shall submit a one-quart (liter) sample of the admixture to the Division Engineer, Materials.  This sample must be accompanied by a manufacturer's certification and guarantee that fully complies with the requirements of the specifications.
 
 
 
:(b) The sample shall be subject to the following Laboratory tests:
 
:::pH--AASHTO T200
 
 
 
:::Specific Gravity (25°C/25°C)--ASTM D1429, Method A - Pycnometer
 
 
 
:::Non Volatile, percent:
 
:::::Air-entraining Agents--ASTM D2369;
 
:::::Retarding Agents, Water Reducing Agents,
 
::::::and Accelerators--AASHTO M194, Section 18.2.
 
 
 
:::Infrared Spectrum
 
 
 
:(c) Upon completion of Laboratory tests and a review of the manufacturer's certification and guarantee, the manufacturer will be notified by letter whether the admixture is prequalified for use.  Each prequalified brand, with the manufacturer's name and address, will be placed on the appropriate list of prequalified material contained in [[:Category:1054 Concrete Admixtures|1054 Concrete Admixtures]].
 
 
 
Destination samples submitted to the Laboratory in accordance with instructions set forth in [[:Category:1054 Concrete Admixtures|1054 Concrete Admixtures]] shall be tested by the methods set forth in the above paragraph.
 
  
All test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through SiteManager.
+
For material shipped directly to a job site by a supplier, the supplier shall notify the State Construction and Materials Engineer prior to shipment using [https://www.modot.org/sites/default/files/documents/construction_and_materials/material_qualified_product_listing/gs013f3.pdf GS-13 Form 3]. When the material is shipped to a mixing facility, that facility shall notify the State Construction and Materials Engineer of its arrival using [https://www.modot.org/sites/default/files/documents/construction_and_materials/material_qualified_product_listing/gs013f2.pdf GS-13 Form 2]. When complete and correct information on the shipment is provided to the State Construction and Materials Engineer, a PAL ID number will be assigned to the material. That number shall be attached to the material container, or be immediately available at the plant, until the material is consumed. The proportioning plant inspector shall continue to show on the daily reports the information required by the [[:Category:500 RIGID PAVEMENT|Construction Inspection Guidelines in the Engineering PolicyGuide’s Rigid Pavement articles]].
  
===1054.3.2 Sample Record===
+
Material purchased for maintenance work may be accepted solely on the basis of the manufacturer and brand being on the Pre-Acceptance List. District Materials will report the receipt and acceptance of the material in AWP and will mark the containers with the sample ID number they assign.
The sample record shall be completed in SiteManager, as described in [[Automation Sec 3510]], and shall indicate acceptance, qualified acceptance, or rejection.  Appropriate remarks, as described in [[106.9 Reporting Test Results|106.9 Reporting Test Results]], are to be included in the remarks to clarify conditions of acceptance or rejection.  Test results shall be reported on the appropriate templates under the Tests tab.
 

Latest revision as of 08:33, 18 October 2021

Forms
GS-13 Form 2
GS-13 Form 3
MGS Information
Current General Services Specifications (MGS) By Subject

This article establishes procedures for inspection, acceptance and reporting of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures and latex emulsion admixtures for use in Portland cement concrete. Refer to Sec 1054 for MoDOT’s specifications.

For Laboratory testing and sample reporting procedures, refer to EPG 1054.3 Laboratory Testing Guidelines for Sec 1054.

1054.1 Apparatus

a) One quart (1 liter) screw top cans that are clean, dry and free of all contaminants.

b) One gallon (4 liter) plastic containers that are clean, dry and free of all contaminants.

1054.2 Procedure

1054.2.1 Pre-Acceptance Lists

Manufacturers and Brand Names of air-entraining admixtures, water-reducing admixtures, retarding admixtures, accelerating admixtures, latex emulsion admixtures and high range water-reducing admixtures will be placed on the Pre-Acceptance List maintained by the State Construction and Materials Engineer in accordance with 1054.2.2 Manufacturer and Brand Name Approval and the applicable specification. These lists are found in Concrete Admixtures Pre-Acceptance List and on MoDOT’s web site.

High range water-reducing admixtures are permitted only when specified in the contract.

1054.2.2 Manufacturer and Brand Name Approval

If a manufacturer desires to have material added to the Pre-Acceptance List of admixtures, a certification and guarantee must be submitted to the State Construction and Materials Engineer in accordance with the requirements of Sec 1054. The certification and guarantee shall be accompanied by a one-quart (1 liter) sample of air-entraining admixture, water-reducing admixture (including high range) or retarding admixture as applicable. A one-gallon (4 liter) sample of accelerating admixture or latex emulsion admixture shall be submitted for qualification. Upon approval of the admixture, it will be placed on the applicable list.

1054.2.3 Basis of Acceptance

Material is accepted by the PAL criteria as indicated in EPG 106.12 Pre-Acceptance Lists (PAL). The State Construction and Materials Engineer will retain the original certification and guarantee. Additional certification is not necessary if the manufacturer and brand of material is clearly identified on the container or the documentation included with bulk shipments.

1054.2.4 Sampling

1054.2.4.1 Manufacturing Facility

Each admixture producer will be assigned to a district office for Facility Review, Sampling and Testing in accordance with EPG 106.12 Pre-Acceptance Lists (PAL). During the visit, samples of material available at the facility should be obtained. Materials selected for sampling will tpically be those that have been used in MoDOT work during the past month. Material originating at locations too far from the assigned district’s office is subject to sampling at an intermediate location or at the job site. It is the assigned district’s responsibility to verify with the supplier that the location seleted for sampling is acceptable to the supplier as a location from which a valid PAL source sample may be obtained.

1054.2.4.2 Mixing Facility

The district shall submit to the Laboratory a representative sample of each admixture being used, at startup or during plant calibration, and at intervals not to exceed six months.

1054.2.4.3 Sample

A sample of air-entraining admixture, water-reducing admixture, or retarding admixture shall consist of one quart (1 liter) of material in a plastic wide-mouth bottle. A sample of accelerating admixture or latex emulsion admixture shall consist of one gallon (4 liters) of material in a plastic container. All samples shall be obtained by the manufacturer or contractor’s agent in accordance with the manufacturer’s sampling instructions. The inspector will observe the sampling process. The sample shall be recorded through AASHTOWARE Project (AWP) showing the manufacturer's name, the brand name and designation of the material, lot number, net quantity represented, and the location where the sample was obtained using the Sampled From and Sample Origin fields of AWP. The Other tab is also used for a Mixing Facility. The PAL ID number obtained by the supplier or mixing facility in accordance with EPG 1054.2.5 Sample Record should be recorded in AWP in the “Link To” field.

1054.2.5 Sample Record

Test results on random samples of admixtures shall be reported by the Laboratory in accordance with EPG 1054.3 Laboratory Testing Guidelines for Sec 1054 and EPG 106.12 Pre-Acceptance Lists (PAL).

For material shipped directly to a job site by a supplier, the supplier shall notify the State Construction and Materials Engineer prior to shipment using GS-13 Form 3. When the material is shipped to a mixing facility, that facility shall notify the State Construction and Materials Engineer of its arrival using GS-13 Form 2. When complete and correct information on the shipment is provided to the State Construction and Materials Engineer, a PAL ID number will be assigned to the material. That number shall be attached to the material container, or be immediately available at the plant, until the material is consumed. The proportioning plant inspector shall continue to show on the daily reports the information required by the Construction Inspection Guidelines in the Engineering PolicyGuide’s Rigid Pavement articles.

Material purchased for maintenance work may be accepted solely on the basis of the manufacturer and brand being on the Pre-Acceptance List. District Materials will report the receipt and acceptance of the material in AWP and will mark the containers with the sample ID number they assign.

Articles in "1054 Concrete Admixtures"