Difference between revisions of "751.18 Concrete Multicell Box Girder Bridges"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (Smithk moved page 751.21 Concrete Box Girder to 751.18 Concrete Multicell Box Girder Bridges: Per BR, renamed and renumbered)
m (Per BR, article renamed and renumbered)
 
Line 1: Line 1:
==751.21.1 Reinforcement==
+
==751.18.1 Reinforcement==
===751.21.1.1 Single Column Design===
+
===751.18.1.1 Single Column Design===
  
 
'''Top Slab Modifications at Intermediate Bent:'''
 
'''Top Slab Modifications at Intermediate Bent:'''
Line 14: Line 14:
 
<center>'''SECTION AT INT. BENT'''<br/>'''(SINGLE COLUMN)'''</center>
 
<center>'''SECTION AT INT. BENT'''<br/>'''(SINGLE COLUMN)'''</center>
  
===751.21.1.2 Web Reinforcement===
+
===751.18.1.2 Web Reinforcement===
  
 
'''Top Slab Modifications at Intermediate Bent:'''
 
'''Top Slab Modifications at Intermediate Bent:'''
Line 22: Line 22:
 
<center>'''TYPICAL SECTION THRU WEB & SLABS'''</center>
 
<center>'''TYPICAL SECTION THRU WEB & SLABS'''</center>
  
==751.21.2 Miscellaneous Details==
+
==751.18.2 Miscellaneous Details==
===751.21.2.1 Access Doors===
+
===751.18.2.1 Access Doors===
  
 
ACCESS DOORS (RECTANGLE)
 
ACCESS DOORS (RECTANGLE)

Latest revision as of 07:38, 2 April 2021

751.18.1 Reinforcement

751.18.1.1 Single Column Design

Top Slab Modifications at Intermediate Bent:

The reinforcement shown below shall be used in place of the design slab steel.


(1) designed slab steel


751.21 cont conc box girders section at int bent single column.gif
SECTION AT INT. BENT
(SINGLE COLUMN)

751.18.1.2 Web Reinforcement

Top Slab Modifications at Intermediate Bent:

751.21 cont conc box girders typical section thru web & slabs.gif
TYPICAL SECTION THRU WEB & SLABS

751.18.2 Miscellaneous Details

751.18.2.1 Access Doors

ACCESS DOORS (RECTANGLE)

751.21 cont conc box girders rectangle access door plan.gif


PLAN


751.21 cont conc box girders rectangle access door sec aa.gif


SECTION A-A


DETAILS OF ACCESS DOORS
WEIGHT 179#


ACCESS DOORS (OVAL)

751.21 cont conc box girders oval access door plan.gif


PLAN


751.21 cont conc box girders oval access door sec aa.gif


SECTION A-A


DETAILS OF ACCESS DOORS


751.21 cont conc box girders oval access door details.gif

See Section 4A for painting or galvanizing note.


ACCESS DOORS LOCATION

751.21 cont conc box girders access door location.gif


  • Generally, access doors shall be positioned on or near 1/4 point of span and centerline of roadway.

It is permissible to shift position of access doors when:

  1. Girder is located at centerline of bridge
  2. To prevent cutting additional slab bars
  3. To clear construction joints
  4. To maintain adequate vertical clearance

If possible, do not locate access doors over a roadway or berm.

751.21 cont conc box girders access door reinforcement.gif
PLAN OF ACCESS DOOR
SHOWING REINFORCEMENT