==721.2 Sample Record== | ==721.2 Sample Record== | ||
− | Test results shall be reported through | + | Test results shall be reported through AASHTOWARE Project (AWP), as described in [[:Category:101 Standard Forms#Sample Record, General|AWP MA Sample Record, General]], with the notation in the remarks, "Specimens submitted for compressive strength at the age indicated and the test results are for informational purposes only". Test results shall be reported on the appropriate templates under the Tests tab. |
Latest revision as of 08:31, 14 September 2021
This article establishes procedures for Laboratory testing and reporting concrete cylinders representing concrete crib-type retaining walls.
721.1 Procedure
Concrete cylinders shall be tested for compressive strength according to AASHTO T22.
721.2 Sample Record
Test results shall be reported through AASHTOWARE Project (AWP), as described in AWP MA Sample Record, General, with the notation in the remarks, "Specimens submitted for compressive strength at the age indicated and the test results are for informational purposes only". Test results shall be reported on the appropriate templates under the Tests tab.