Difference between revisions of "Category:302 Stabilized Permeable Base"
m (Minor correction in Spec reference) |
m (updated links) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 8: | Line 8: | ||
====302.1.2.2 Asphalt Stabilized Permeable Base (Sec 302.2.2)==== | ====302.1.2.2 Asphalt Stabilized Permeable Base (Sec 302.2.2)==== | ||
− | All proportioning, mixing, and transporting shall be in accordance with [http://modot. | + | All proportioning, mixing, and transporting shall be in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=7 Sec 401]. |
====302.1.2.3 Cement Stabilized Permeable Base (Sec 302.2.3)==== | ====302.1.2.3 Cement Stabilized Permeable Base (Sec 302.2.3)==== | ||
− | All proportioning, mixing, and transporting shall be in accordance with [http://modot. | + | All proportioning, mixing, and transporting shall be in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=8 Sec 501]. Fly ash and ground granulated blast furnace slag shall not be used. Cement and water must conform to specific material requirements of [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1019] and [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1070]. Water must be free from substances deleterious to hardening of cement. Water from sources approved for drinking purposes is normally satisfactory. |
===302.1.3 Construction Requirements (Sec 302.3)=== | ===302.1.3 Construction Requirements (Sec 302.3)=== | ||
Line 25: | Line 25: | ||
====302.1.3.3 Asphalt Stabilized Permeable Base (Sec 302.3.3)==== | ====302.1.3.3 Asphalt Stabilized Permeable Base (Sec 302.3.3)==== | ||
− | Applicable sections of [http://modot. | + | Applicable sections of [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=7 Sec 401] apply, except as noted herein. Observe temperature requirements and the rolling of asphalt treated bases to ensure compaction meets specifications. Ensure minimum lift thicknesses are maintained and document. |
====302.1.3.4 Cement Stabilized Permeable Base (Sec 302.3.4)==== | ====302.1.3.4 Cement Stabilized Permeable Base (Sec 302.3.4)==== | ||
− | Cement Stabilized Permeable Base consists of base aggregate, cement, and water uniformly mixed, hauled and spread in one layer, compacted, finished, and cured in accordance with [http://modot. | + | Cement Stabilized Permeable Base consists of base aggregate, cement, and water uniformly mixed, hauled and spread in one layer, compacted, finished, and cured in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=8 Sec 501] of Standard Specifications, and in reasonably close conformity with lines, grades, thickness, |
and typical cross sections shown on the plans. | and typical cross sections shown on the plans. | ||
− | Subgrade should be prepared and shaped in accordance with [http://modot. | + | Subgrade should be prepared and shaped in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=5 Sec 209] of Standard Specifications. Soft or spongy areas in subgrade should be removed, replaced with satisfactory |
material, and properly compacted. All drainage conduit, including underdrain if required, | material, and properly compacted. All drainage conduit, including underdrain if required, | ||
should be in place. | should be in place. | ||
Line 48: | Line 48: | ||
===302.2.1 Procedure=== | ===302.2.1 Procedure=== | ||
− | |||
− | |||
− | ====302.2.2.2 Cement Stabilized Permeable Base==== | + | ====302.2.1.1 Production Testing==== |
− | Proportioning, mixing, and transporting are to be in accordance with the applicable requirements of [http://modot. | + | The QC tests and frequencies for these materials are covered in the table below. |
+ | |||
+ | {| border="1" cellpadding="5" cellspacing="0" | ||
+ | |- style="background:#CCCCCC" | ||
+ | ! Type of Construction or Material || Tests to be Made (if specified) || Sampled || Minimum Number of Tests | ||
+ | |- | ||
+ | |'''Stabilized Permeable Base'''||align="center"| Graduation SAA002UB||align="center"|Before compactions||One per 5,000 tons (5,000 megagrams) or fraction thereof per specified graduation source. None required if less than 1,000 tons (1,000 megagrams) of a specified graduation. | ||
+ | |} | ||
+ | |||
+ | ====302.2.1.2 Asphalt Stabilized Permeable Base==== | ||
+ | Mix design procedures are identical to those shown in [[:Category:401 Bituminous Base and Pavement#401.3 Materials Inspection for Sec 401|Materials Inspection for Sec 401]]. However, trial mix samples shall not be obtained unless requested by the Field Office. Proportioning, mixing, and transporting are to be in accordance with the applicable requirements of [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=7 Sec 401]. | ||
+ | |||
+ | ====302.2.1.3 Cement Stabilized Permeable Base==== | ||
+ | Proportioning, mixing, and transporting are to be in accordance with the applicable requirements of [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=7 Sec 501]. | ||
+ | |||
+ | [[image:302.jpg|center|800px]] |
Latest revision as of 14:01, 8 June 2016
Contents
302.1 Construction Inspection for Sec 302
302.1.1 Description (Sec 302.1)
Treated permeable base provides a structural, highly permeable drainage layer. This work consist of furnishing and placing a stabilized permeable base material.
302.1.2 Material (Sec 302.2)
302.1.2.1 General (Sec 302.2.1)
Stabilized permeable base shall be either asphalt binder stabilized or Portland cement stabilized at the option of the contractor.
302.1.2.2 Asphalt Stabilized Permeable Base (Sec 302.2.2)
All proportioning, mixing, and transporting shall be in accordance with Sec 401.
302.1.2.3 Cement Stabilized Permeable Base (Sec 302.2.3)
All proportioning, mixing, and transporting shall be in accordance with Sec 501. Fly ash and ground granulated blast furnace slag shall not be used. Cement and water must conform to specific material requirements of Sec 1019 and Sec 1070. Water must be free from substances deleterious to hardening of cement. Water from sources approved for drinking purposes is normally satisfactory.
302.1.3 Construction Requirements (Sec 302.3)
Review the general construction requirements listed in Construction Inspection for Bases and Aggregate Surfaces. Many of the requirements for producing and placing treated permeable bases are also those specified for asphalt concrete, portland cement concrete, and portland cement concrete pavement. Check the appropriate specifications for applicable provision.
302.1.3.1 Contamination (Sec 302.3.1)
Contamination, filling voids with foreign material, will destroy the bases’ function. The engineer should be alert to this problem and require the contractor to take steps to ensure the base remains free of any foreign material.
302.1.3.2 Displacement (Sec 302.3.2)
Rutting effects the ability of the base to drain and results in areas of deficient thickness. Rutting or other displacement of the permeable base or the underlying base is not permitted. If displacement occurs, which could result in ponding or a non-uniform, non-draining thickness of permeable base, the material must be completely removed without disturbing the adjacent or underlying material and shall be replaced at the contractor’s expense.
302.1.3.3 Asphalt Stabilized Permeable Base (Sec 302.3.3)
Applicable sections of Sec 401 apply, except as noted herein. Observe temperature requirements and the rolling of asphalt treated bases to ensure compaction meets specifications. Ensure minimum lift thicknesses are maintained and document.
302.1.3.4 Cement Stabilized Permeable Base (Sec 302.3.4)
Cement Stabilized Permeable Base consists of base aggregate, cement, and water uniformly mixed, hauled and spread in one layer, compacted, finished, and cured in accordance with Sec 501 of Standard Specifications, and in reasonably close conformity with lines, grades, thickness, and typical cross sections shown on the plans.
Subgrade should be prepared and shaped in accordance with Sec 209 of Standard Specifications. Soft or spongy areas in subgrade should be removed, replaced with satisfactory material, and properly compacted. All drainage conduit, including underdrain if required, should be in place.
Ensure minimum lift thicknesses are maintained and documented.
302.1.4 Method of Measurement (Sec 302.4)
Final measurement of the completed permeable base will not be made except for authorized changes during construction or where appreciable errors are found in the contract quantity.
302.1.5 Basis of Payment (Sec 302.5)
The accepted quantities of permeable base of the thickness specified will be paid for at the contract unit price for each of the pay items included in the contract.
302.2 Material Inspection for Sec 302
This guidance establishes procedures for mix design of stabilized permeable base. Ingredients for use in stabilized permeable base are to be inspected in accordance with the applicable Materials Inspection Guidance.
302.2.1 Procedure
302.2.1.1 Production Testing
The QC tests and frequencies for these materials are covered in the table below.
Type of Construction or Material | Tests to be Made (if specified) | Sampled | Minimum Number of Tests |
---|---|---|---|
Stabilized Permeable Base | Graduation SAA002UB | Before compactions | One per 5,000 tons (5,000 megagrams) or fraction thereof per specified graduation source. None required if less than 1,000 tons (1,000 megagrams) of a specified graduation. |
302.2.1.2 Asphalt Stabilized Permeable Base
Mix design procedures are identical to those shown in Materials Inspection for Sec 401. However, trial mix samples shall not be obtained unless requested by the Field Office. Proportioning, mixing, and transporting are to be in accordance with the applicable requirements of Sec 401.
302.2.1.3 Cement Stabilized Permeable Base
Proportioning, mixing, and transporting are to be in accordance with the applicable requirements of Sec 501.