Difference between revisions of "Category:450 Bituminous Pavement Design"
m (EPG Asphalt over Rubblized Pavement (article from 2007; no appreciable history; 1253 hits) info moved to EPG 450.8.) |
(updated per RR 3644) |
||
(18 intermediate revisions by 5 users not shown) | |||
Line 3: | Line 3: | ||
|'''Figures''' | |'''Figures''' | ||
|- | |- | ||
− | |[[Media:450 Estimate Factors. | + | |[[Media:450 Estimate Factors 2018.doc| Estimate Factors]] |
|} | |} | ||
==450.1 Asphalt Binder== | ==450.1 Asphalt Binder== | ||
− | Performance grade (PG) asphalt binders are identified by their desired "high temperature" (e.g. "64", "70", "76", etc.) and "low temperature" (e.g. "-22", "-28", "-34", etc.) characteristics. | + | Performance grade (PG) asphalt binders are identified by their desired "high temperature" (e.g. "64", "70", "76", etc.) and "low temperature" (e.g. "-22", "-28", "-34", etc.) characteristics. The temperature numbers represent Celsius degrees and are used in 6 degree increments. The high temperature value is associated with controlling rutting, while the low temperature value is associated with resisting cold weather cracking. The following table should be used as a guide to select asphalt binder grades for bituminous mixtures. Occasionally, asphalt grading will be noted with MSCR Grading notations, as per AASHTO M 332. For instance, PG64-22H is a MSCR graded asphalt that is an allowed replacement for PG70-22. Equivalent grading is specified in Sec. 1015.10.3.1. |
{| border="1" class="wikitable" style="margin: 1em auto 1em auto" | {| border="1" class="wikitable" style="margin: 1em auto 1em auto" | ||
Line 45: | Line 45: | ||
|} | |} | ||
− | The low temperature number is to remain as indicated in the above table. | + | The low temperature number is to remain as indicated in the above table unless specifying a Surface Level or BP surface mix in one of the northern districts. To improve thermal crack resistance, a PG58H-28 should be specified on minor routes in the Northwest and Northeast Districts. |
+ | |||
+ | The high temperature numbers have been set for the traffic loads and operation speeds normally associated with these corridors. The high temperature numbers are recommended minimums and are not to be reduced; however, may be raised to a PG 70-22 or PG 76-22, when deemed necessary, to accommodate actual or anticipated traffic conditions. Typically, the high temperature number should be raised one increment (6 degrees) when traffic speeds are expected to be in the range of 12 to 45 mph and raised two increments (12 degrees) for extremely slow traffic of < 12 mph. Typical candidates for these high temperature number raises are roadways with AADT greater than 3500 that are in a highly congested, urbanized area, have frequent stop and go traffic, or have steep grades with significantly slow traffic speeds. Use of any other PG asphalt binder must be approved by the State Construction and Materials Engineer. | ||
If a higher type PG asphalt binder is warranted, it shall be used in the surface mixture and the first lift of the underlying mixture. | If a higher type PG asphalt binder is warranted, it shall be used in the surface mixture and the first lift of the underlying mixture. | ||
Line 51: | Line 53: | ||
==450.2 Mix Selection== | ==450.2 Mix Selection== | ||
− | The following table should be used as a guide in selecting the appropriate asphalt mix. See [[Thickness Determination]] for additional mix selection discussion regarding minor road spot improvements. | + | The following table should be used as a guide in selecting the appropriate asphalt mix. See [[Other Aspects of Pavement Design#Thickness Determination|Thickness Determination]] for additional mix selection discussion regarding minor road spot improvements. |
{| border="1" class="wikitable" style="margin: 1em auto 1em auto" | {| border="1" class="wikitable" style="margin: 1em auto 1em auto" | ||
Line 65: | Line 67: | ||
|Minor Routes|| Total Average 24 Hour Commercial Truck Traffic <math>\approx</math> 600 or greater || Superpave<sup>(2)</sup> | |Minor Routes|| Total Average 24 Hour Commercial Truck Traffic <math>\approx</math> 600 or greater || Superpave<sup>(2)</sup> | ||
|- | |- | ||
− | |Minor Routes|| | + | |Minor Routes|| AADT > 3500 and Total Average 24 Hour Commercial Truck Traffic < 600 ||| BP-1 (Sec 401) |
|- | |- | ||
− | ||Minor Routes|| | + | ||Minor Routes|| AADT < 3500 and Total Average 24 Hour Commercial Truck Traffic < 600 ||| BP-1 or BP-2<sup>(3)</sup> |
|- | |- | ||
|colspan="3" style="background:#99CC99"|<sup>(1)</sup>Note: Requires JSP to include appropriate smoothness requirements. | |colspan="3" style="background:#99CC99"|<sup>(1)</sup>Note: Requires JSP to include appropriate smoothness requirements. | ||
Line 77: | Line 79: | ||
==450.3 Layer Design== | ==450.3 Layer Design== | ||
+ | {|style="padding: 0.3em; margin-left:15px; border:1px solid #a9a9a9; text-align:center; font-size: 95%; background:#f5f5f5" width="340px" align="right" | ||
+ | |- | ||
+ | |[[media:450 Options.pdf|Min. Placement Depths and Min. %AC by Volume for Asphalt Treatment Options]] | ||
+ | |} | ||
+ | |||
+ | |||
'''Minimum Lift Thickness''' | '''Minimum Lift Thickness''' | ||
Line 83: | Line 91: | ||
{| border="1" class="wikitable" style="margin: 1em auto 1em auto" | {| border="1" class="wikitable" style="margin: 1em auto 1em auto" | ||
|+ | |+ | ||
− | ! style="background:#BEBEBE"| SP250 !! style="background:#BEBEBE"| SP190 !! style="background:#BEBEBE"| SP125 !! style="background:#BEBEBE"| | + | ! style="background:#BEBEBE"| SP250 !! style="background:#BEBEBE"| SP190 !! style="background:#BEBEBE"| SP125<sup>'''1'''</sup> !! style="background:#BEBEBE"| SP095<sup>'''1'''</sup> !! style="background:#BEBEBE"| SP048<sup>'''1'''</sup> |
+ | |- | ||
+ | |align="center"| 4 in. ||align="center"| 3 in. ||align="center"| 2 in. ||align="center"| 1½ in. ||align="center"| 1 in. | ||
|- | |- | ||
− | | | + | |colspan="5" width="750"|<sup>'''1'''</sup> When used as the riding surface. When used as a leveling course below the top lift, the minimum lift thickness should be in accordance with [[#450.4 Level Course|EPG 450.4 Level Course]]. |
|} | |} | ||
+ | |||
+ | {| border="1" class="wikitable" style="margin: 1em auto 1em auto" | ||
+ | |+ | ||
+ | ! style="background:#BEBEBE"|PMBB !!style="background:#BEBEBE"| BP-1<sup>'''1'''</sup> !!style="background:#BEBEBE"|BP-2<sup>'''1'''</sup> !!style="background:#BEBEBE"| BP-3<sup>'''1'''</sup> | ||
+ | |- | ||
+ | |align="center"| 3 in. ||align="center"| 2 in. ||align="center"| 1½ in.||align="center"| 1 in. | ||
+ | |- | ||
+ | |colspan="4" width="550"|<sup>'''1'''</sup> When used as the riding surface. When used as a leveling course below the top lift, the minimum lift thickness should be in accordance with [[#450.4 Level Course|EPG 450.4 Level Course]]. | ||
+ | |} | ||
+ | |||
+ | The above minimum lift thicknesses are recommended to ensure adequate field density can be achieved and a quality product can be provided. The minimum lift thicknesses do not account for surface irregularities in the roadway. Additional asphalt quantities should be included with single lift asphalt overlays to account for the surface irregularities. The additional asphalt quantities added should be in accordance with the average rutting depth measurements from the roadway as provided in [[:Category:402 Bituminous Surface Leveling#402.1.2 Mix and Quantities|Table 402.1.2.1]]. | ||
+ | |||
+ | Central Office Construction and Materials may recommend thicknesses greater than the above minimums but projects should not be designed for thicknesses less than the above minimums. If using the minimum lift thickness criteria results in the project exceeding its budget, then a finer gradation asphalt mixture should be used and designed for its minimum lift thickness or greater (for example, if 2 in. of BP-1 exceeds project budget, use 1.5 in. or greater of BP-2). | ||
==450.4 Level Course== | ==450.4 Level Course== | ||
− | Existing surfaces, both asphaltic and portland cement concrete, should be prepared either by milling or leveling course before the first full-thickness lift of asphalt is placed. Milling is the preferred method of leveling, however PMBP or | + | Existing surfaces, both asphaltic and portland cement concrete, should be prepared either by milling or leveling course before the first full-thickness lift of asphalt is placed. Milling is the preferred method of leveling, however PMBP or SP asphaltic concrete may be used for spot wedging and for leveling course as per the standard specifications, providing the minimum thickness is not less than the following: |
{| border="1" class="wikitable" style="margin: 1em auto 1em auto" | {| border="1" class="wikitable" style="margin: 1em auto 1em auto" | ||
|+ | |+ | ||
− | ! style="background:#BEBEBE"| BP-1 and SP125 !! style="background:#BEBEBE"| BP-2 and | + | ! style="background:#BEBEBE"| BP-1 and SP125 !! style="background:#BEBEBE"| BP-2 and SP095 !! style="background:#BEBEBE"| BP-3 and SP048 |
|- | |- | ||
− | | | + | |align="center" width="155"| 1¾ in. ||align="center" width="155"| 1¼ in. ||align="center" width="155"| ¾ in. |
|} | |} | ||
The level course can be one design level lower than the lift above it. For example, an SP level C design may be used to level under an SP level B overlay. A BP mix may be used to level under an SP Level C overlay. | The level course can be one design level lower than the lift above it. For example, an SP level C design may be used to level under an SP level B overlay. A BP mix may be used to level under an SP Level C overlay. | ||
− | |||
==450.5 Payment== | ==450.5 Payment== | ||
− | Payment for asphaltic concrete by the square yard should only be used for full depth asphaltic concrete pavements on alternate bid projects. All other payment for asphaltic concrete should be by the ton. For preliminary design, [[Media:450 Estimate Factors. | + | Payment for asphaltic concrete by the square yard should only be used for full depth asphaltic concrete pavements on alternate bid projects. All other payment for asphaltic concrete should be by the ton. For preliminary design, [[Media:450 Estimate Factors 2018.doc|estimate factors]] may be used to compute quantities for bases, flexible type pavements, seal coats, etc. For final design, the designer should request estimate factors for anticipated rock formations from the District Construction and Materials Engineer to obtain more reliable results. When payment is by the ton, estimate factors should be shown on the plans with a note "For Information Purposes Only." When payment is by the square yard, estimate factors should not be shown on the plans. |
==450.6 Automatic Screed Control or Established Grade Reference== | ==450.6 Automatic Screed Control or Established Grade Reference== | ||
Line 121: | Line 143: | ||
There must be adequate subgrade support under old rigid pavements. Dynamic cone penetrometer (DCP) testing of the unbound layers under the PCC pavement, performed during the condition surveys, must indicate that adequate support exists for rubblization to occur. | There must be adequate subgrade support under old rigid pavements. Dynamic cone penetrometer (DCP) testing of the unbound layers under the PCC pavement, performed during the condition surveys, must indicate that adequate support exists for rubblization to occur. | ||
+ | |||
+ | ==450.9 Safety Edge<sup>SM</sup>== | ||
+ | |||
+ | Shaping the edge of pavement to a 30-degree bevel is an effective strategy for mitigating the negative effects associated with vertical edge drop-off. Refer to [https://www.modot.org/media/16832 Std. Plan 401.00]. | ||
+ | |||
+ | As with conventional paving, the graded material adjacent to the Safety Edge<sup>SM</sup> should be brought flush with the top of the pavement following paving. If this material should settle or be otherwise displaced in the future, however, the Safety Edge<sup>SM</sup> would continue to provide a durable height transition to smoothly conduct vehicles back to the paved road. | ||
+ | |||
+ | Safety Edge<sup>SM</sup> must be included in all single-lift overlay projects when the finished surface will be 21 ft. wide or greater. This includes shoulder paving unless the paved width of each shoulder exceeds 4 ft. When using the Safety Edge<sup>SM</sup>, the quantity of asphalt mix will increase by approximately 2 percent. |
Latest revision as of 08:24, 19 April 2023
Figures |
Estimate Factors |
Contents
450.1 Asphalt Binder
Performance grade (PG) asphalt binders are identified by their desired "high temperature" (e.g. "64", "70", "76", etc.) and "low temperature" (e.g. "-22", "-28", "-34", etc.) characteristics. The temperature numbers represent Celsius degrees and are used in 6 degree increments. The high temperature value is associated with controlling rutting, while the low temperature value is associated with resisting cold weather cracking. The following table should be used as a guide to select asphalt binder grades for bituminous mixtures. Occasionally, asphalt grading will be noted with MSCR Grading notations, as per AASHTO M 332. For instance, PG64-22H is a MSCR graded asphalt that is an allowed replacement for PG70-22. Equivalent grading is specified in Sec. 1015.10.3.1.
Type of Corridor | Traffic Level | Type of Mix | Asphalt Binder |
---|---|---|---|
Interstates and Other Freeways | All Levels | Surface Mixture (SP125 or SMA) and First Underlying Lift | PG 76-22 |
Remaining Underlying Lifts | PG 64-22 | ||
Other Remaining Major Routes | Heavy Volume | Surface Mixture (SP125) and First Underlying Lift | PG 70-22 |
Remaining Underlying Lifts | PG 64-22 | ||
Medium or Low Volume | Surface Mixture (SP125 or BP)* | PG 64-22 | |
Underlying Lifts | PG 64-22 | ||
Minor Routes | All Levels | All Mixtures (Generally BP-1 as Surface Mix) | PG 64-22 |
*Note: Requires JSP to include appropriate smoothness requirements. |
The low temperature number is to remain as indicated in the above table unless specifying a Surface Level or BP surface mix in one of the northern districts. To improve thermal crack resistance, a PG58H-28 should be specified on minor routes in the Northwest and Northeast Districts.
The high temperature numbers have been set for the traffic loads and operation speeds normally associated with these corridors. The high temperature numbers are recommended minimums and are not to be reduced; however, may be raised to a PG 70-22 or PG 76-22, when deemed necessary, to accommodate actual or anticipated traffic conditions. Typically, the high temperature number should be raised one increment (6 degrees) when traffic speeds are expected to be in the range of 12 to 45 mph and raised two increments (12 degrees) for extremely slow traffic of < 12 mph. Typical candidates for these high temperature number raises are roadways with AADT greater than 3500 that are in a highly congested, urbanized area, have frequent stop and go traffic, or have steep grades with significantly slow traffic speeds. Use of any other PG asphalt binder must be approved by the State Construction and Materials Engineer.
If a higher type PG asphalt binder is warranted, it shall be used in the surface mixture and the first lift of the underlying mixture.
450.2 Mix Selection
The following table should be used as a guide in selecting the appropriate asphalt mix. See Thickness Determination for additional mix selection discussion regarding minor road spot improvements.
Corridor Designation | Traffic | Recommended Mix |
---|---|---|
Interstates and Other Freeways | All Traffic | Superpave |
Remaining Major Routes | Total Average 24 Hour Commercial Truck Traffic 600 or greater | Superpave |
Remaining Major Routes | Total Average 24 Hour Commercial Truck Traffic less than 600 | BP-1 (Sec 401)(1)(2) |
Minor Routes | Total Average 24 Hour Commercial Truck Traffic 600 or greater | Superpave(2) |
Minor Routes | AADT > 3500 and Total Average 24 Hour Commercial Truck Traffic < 600 | BP-1 (Sec 401) |
Minor Routes | AADT < 3500 and Total Average 24 Hour Commercial Truck Traffic < 600 | BP-1 or BP-2(3) |
(1)Note: Requires JSP to include appropriate smoothness requirements. | ||
(2)Note: Consideration should be given to alter mix type for overlays based upon existing conditions. | ||
(3)Note: The selection of which mix to use is left to the district's discretion based upon past field performance. |
450.3 Layer Design
Min. Placement Depths and Min. %AC by Volume for Asphalt Treatment Options |
Minimum Lift Thickness
The minimum lift thicknesses for asphalt layers should be:
SP250 | SP190 | SP1251 | SP0951 | SP0481 |
---|---|---|---|---|
4 in. | 3 in. | 2 in. | 1½ in. | 1 in. |
1 When used as the riding surface. When used as a leveling course below the top lift, the minimum lift thickness should be in accordance with EPG 450.4 Level Course. |
PMBB | BP-11 | BP-21 | BP-31 |
---|---|---|---|
3 in. | 2 in. | 1½ in. | 1 in. |
1 When used as the riding surface. When used as a leveling course below the top lift, the minimum lift thickness should be in accordance with EPG 450.4 Level Course. |
The above minimum lift thicknesses are recommended to ensure adequate field density can be achieved and a quality product can be provided. The minimum lift thicknesses do not account for surface irregularities in the roadway. Additional asphalt quantities should be included with single lift asphalt overlays to account for the surface irregularities. The additional asphalt quantities added should be in accordance with the average rutting depth measurements from the roadway as provided in Table 402.1.2.1.
Central Office Construction and Materials may recommend thicknesses greater than the above minimums but projects should not be designed for thicknesses less than the above minimums. If using the minimum lift thickness criteria results in the project exceeding its budget, then a finer gradation asphalt mixture should be used and designed for its minimum lift thickness or greater (for example, if 2 in. of BP-1 exceeds project budget, use 1.5 in. or greater of BP-2).
450.4 Level Course
Existing surfaces, both asphaltic and portland cement concrete, should be prepared either by milling or leveling course before the first full-thickness lift of asphalt is placed. Milling is the preferred method of leveling, however PMBP or SP asphaltic concrete may be used for spot wedging and for leveling course as per the standard specifications, providing the minimum thickness is not less than the following:
BP-1 and SP125 | BP-2 and SP095 | BP-3 and SP048 |
---|---|---|
1¾ in. | 1¼ in. | ¾ in. |
The level course can be one design level lower than the lift above it. For example, an SP level C design may be used to level under an SP level B overlay. A BP mix may be used to level under an SP Level C overlay.
450.5 Payment
Payment for asphaltic concrete by the square yard should only be used for full depth asphaltic concrete pavements on alternate bid projects. All other payment for asphaltic concrete should be by the ton. For preliminary design, estimate factors may be used to compute quantities for bases, flexible type pavements, seal coats, etc. For final design, the designer should request estimate factors for anticipated rock formations from the District Construction and Materials Engineer to obtain more reliable results. When payment is by the ton, estimate factors should be shown on the plans with a note "For Information Purposes Only." When payment is by the square yard, estimate factors should not be shown on the plans.
450.6 Automatic Screed Control or Established Grade Reference
The standard specifications require the use of automatic screed controls with the sensor following a traveling reference plane. In some instances, such as a badly warped pavement or very poor riding condition, the use of an established grade reference may be desirable. If the established grade reference is desired, a special provision must be included in the contract requiring its use for the initial pass of the paver when placing the first continuous layer. The special provision may be modified to require the established grade reference for a portion of a project if necessary.
450.7 Commercial Mixtures
The standard specifications permit the use of approved commercial mixture for plant mix bituminous pavement and plant mix bituminous base course when so specified in the contract. Commercial mixtures are not permitted where Section 403 or Superpave mixtures are specified. Care should be exercised when setting up small quantities of asphaltic concrete in that it may be more desirable, all factors considered, to use plant mix bituminous pavement so that a commercial mixture can be permitted.
450.8 Asphalt Over Rubblized Pavement
Rubblization is the in-place breaking of an existing Portland Cement Concrete (PCC) pavement into an aggregate base for new hot mix asphalt. When major asphalt rehabilitation over existing concrete pavement is considered the existing pavement is rubblized prior to the asphalt overlay. If the existing pavement consists of asphalt over concrete the existing asphalt should be removed prior to rubblization.
When rubblization is used, the asphalt is paid for by the ton of mix necessary to obtain the thickness indicated by Construction and Materials. The plan quantity should be established with consideration for thickness in excess of that specified to account for irregularities in the existing pavement. Similar to unbonded overlay the contractor is required to establish the existing roadway profile and set the final overlay profile. For this reason the bid item for contractor staking should be included in the contract.
There must be adequate subgrade support under old rigid pavements. Dynamic cone penetrometer (DCP) testing of the unbound layers under the PCC pavement, performed during the condition surveys, must indicate that adequate support exists for rubblization to occur.
450.9 Safety EdgeSM
Shaping the edge of pavement to a 30-degree bevel is an effective strategy for mitigating the negative effects associated with vertical edge drop-off. Refer to Std. Plan 401.00.
As with conventional paving, the graded material adjacent to the Safety EdgeSM should be brought flush with the top of the pavement following paving. If this material should settle or be otherwise displaced in the future, however, the Safety EdgeSM would continue to provide a durable height transition to smoothly conduct vehicles back to the paved road.
Safety EdgeSM must be included in all single-lift overlay projects when the finished surface will be 21 ft. wide or greater. This includes shoulder paving unless the paved width of each shoulder exceeds 4 ft. When using the Safety EdgeSM, the quantity of asphalt mix will increase by approximately 2 percent.
Articles in "450 Bituminous Pavement Design"
The following 2 pages are in this category, out of 2 total.