Difference between revisions of "Category:505 Bridge Deck Concrete Wearing Surface"
Line 58: | Line 58: | ||
===505.2.2 Procedure=== | ===505.2.2 Procedure=== | ||
====505.2.2.1 Silica Fume Admixture==== | ====505.2.2.1 Silica Fume Admixture==== | ||
− | A qualified list of silica fume admixtures is shown in [[#505.2.5 Qualified Silica Fume Admixture]]. If an admixture is proposed for use and does not appear in the qualified list, the State Construction and Materials Engineer is to be notified to obtain procedures for qualification. | + | A qualified list of silica fume admixtures is shown in [[#505.2.5 Qualified Silica Fume Admixture|Qualified Silica Fume Admixture]]. If an admixture is proposed for use and does not appear in the qualified list, the State Construction and Materials Engineer is to be notified to obtain procedures for qualification. |
====505.2.3 Acceptance==== | ====505.2.3 Acceptance==== |
Revision as of 10:47, 19 April 2007
Contents
505.1 Construction Inspection (for Sec 505)
505.1.1 Low Slump Concrete (for Sec 505.10)
This wearing surface is designed to prevent the intrusion of water and salt to the reinforcing steel thus slowing the rusting process. It is, therefore, very important that the surface be finished properly. The pour should be planned to minimize the combined effect of hot atmospheric temperatures, low humidity, hot concrete temperatures, high winds and dusty conditions. Even if all are individually within specifications, a combination of these conditions can cause rapid drying of the surface resulting in tearing or cracking. If the deck cannot be sealed properly, the pour should be stopped.
505.1.1.1 Description (for Sec 505.10.1)
A low slump concrete wearing surface is sometimes specified for structure work. This work consists of placing a dense low slump overlay on a prepared surface of either an existing concrete deck on a new structure.
505.1.1.2 Material (for Sec 505.10.2)
505.1.1.3 Concrete Mixture (for Sec 505.10.3)
(Sec 505.10.3.1) The contractor shall submit a mix design mix to District Materials meeting the low slump concrete specifications for review and approval. Representative samples may need to be sent to Construction and Materials for laboratory testing.
505.1.1.4 Testing (for Sec 505.10.4)
(Sec 505.10.4.1) See Consistency
(Sec 505.10.4.2) See Air-Entrained Concrete
(Sec 505.10.4.6) Refer to MoDOT Test Method TM 36.
505.1.1.5 Finishing Equipment (for Sec 505.10.7)
(Sec 505.10.7.1) It is important for the finishing machine to be in proper adjustment so that very little hand work is necessary to seal the surface.
505.1.2 Latex Modified Concrete (Sec 505.20)
This wearing surface is designed to prevent the intrusion of water and salt to the reinforcing steel thus slowing the rusting process. It is, therefore, very important that the surface be finished properly. The pour should be planned to minimize the combined effect of hot atmospheric temperatures, low humidity, hot concrete temperatures, high winds and dusty conditions. Even if all are individually within specifications, a combination of these conditions can cause rapid drying of the surface resulting in tearing or cracking. If the deck cannot be sealed properly, the pour should be stopped.
505.1.2.1 Description (for Sec 505.20.1)
A latex modified concrete wearing surface is sometimes specified for structure work. This work consists of placing a dense low slump overlay on a prepared surface of either an existing concrete deck on a new structure.
505.1.2.2 Concrete Mixture (for Sec 505.20.3)
(Sec 505.20.3.1) The contractor shall submit a mix design mix to District Materials meeting the latex modified concrete specifications for review and approval. Representative samples may need to be sent to Construction and Materials for laboratory testing.
505.1.2.3 Mixing (for Sec 505.20.5)
(Sec 505.20.5.1) See [Category:501 Concrete#501.1.7 Volumetric Batched and Continuous Mixed Concrete (Sec 501.9)|Volumetric Batched and Continuous Mixed Concrete]].
505.1.2.4 Finishing Equipment (for Sec 505.20.7)
(Sec 505.20.7.1) It is important for the finishing machine to be in proper adjustment so that very little hand work is necessary to seal the surface.
505.1.3 Silica Fume Concrete (for Sec 505.30)
This wearing surface is designed to prevent the intrusion of water and salt to the reinforcing steel thus slowing the rusting process. It is, therefore, very important that the surface be finished properly. The pour should be planned to minimize the combined effect of hot atmospheric temperatures, low humidity, hot concrete temperatures, high winds and dusty conditions. Even if all are individually within specifications, a combination of these conditions can cause rapid drying of the surface resulting in tearing or cracking. If the deck cannot be sealed properly, the pour should be stopped.
505.1.3.1 Description (for Sec 505.30.1)
A silica fume concrete wearing surface is sometimes specified for structure work. This work consists of placing a dense low slump overlay on a prepared surface of either an existing concrete deck on a new structure.
505.1.3.2 Concrete Mixture (for Sec 505.30.3)
(Sec 505.30.3.1) The contractor shall submit a mix design mix to District Materials meeting the silica fume concrete specifications for review and approval. Representative samples may need to be sent to Construction and Materials for laboratory testing.
505.1.3.3 Finishing Equipment (for Sec 505.30.7)
It is important for the finishing machine to be in proper adjustment so that very little hand work is necessary to seal the surface.
505.2 Materials Inspection (for Sec 505)
505.2.1 Scope
This section is to establish procedures for inspecting and reporting admixtures for use in Bridge Deck Concrete Wearing Surfaces.
505.2.2 Procedure
505.2.2.1 Silica Fume Admixture
A qualified list of silica fume admixtures is shown in Qualified Silica Fume Admixture. If an admixture is proposed for use and does not appear in the qualified list, the State Construction and Materials Engineer is to be notified to obtain procedures for qualification.
505.2.3 Acceptance
Acceptance of admixtures is based on brand name approval, correct certification and information as required by specifications and any tests deemed necessary.
505.2.4 Sample Record
Silica fume admixtures are to be reported through SiteManager.
505.2.5 Qualified Silica Fume Admixture
Brand Name | Manufacturer |
---|---|
EMS-970DA (3/02) | Elkem Materials
P.O. Box 266 Pittsburgh, PA 15230 |
EMS-970S (3/02) | Elkem Materials
P.O. Box 266 Pittsburgh, PA 15230 |
Rheomac SF 100 (dry form) Rheomac SF 100 (slurry form) (1/02) | Master Builders 23700 Chagrin Blvd. Cleveland, OH 44122 |
Force 10,000D (9/03) | W.R. Grace and Co.
62 Whittemore Avenue Cambridge, MA 02140 |