Category:1017 Slag Cement
This guidance establishes procedures for inspecting, sampling, testing and accepting Ground Granulated Blast Furnace Slag (GGBFS) at the source and destination and establishes a list of qualified GGBFS sources.
Approved Products |
GGBFS Qualified Sources |
MGS Information |
Current General Services Specifications (MGS) By Subject |
Contents
1017.1 Apparatus
Keep all sample containers and equipment used in sampling clean and free of moisture or any foreign material. It is important that the sample be kept in airtight, moisture-proof containers from the time it is obtained until tests are started. The apparatus consists of:
- (a) Canvas bags with plastic liners.
- (b) Rubber bands for securely fastening the top of plastic liners.
- (c) Slotted tube, tube sampler, scoop, or any other device suitable for obtaining the sample.
- (d) Labeling materials.
1017.2 Procedure
Concrete, 70% GGBFS |
Report 2006 |
Summary 2006 |
See also: Innovation Library |
1017.2.1 Source Acceptance and Qualification
All GGBFS for use in MoDOT projects must be furnished from a manufacturer or terminal and must comply with the requirements of Sec 1017. The procedures for qualification are listed in Specification Sec 1017. Direct questions from potential suppliers concerning qualification to the Central Office. A copy of each manufacturer's quality control plan is to be kept on file in the Central Office. The latest copy of each marketing entity's quality control plan is to be kept on file in the Central Office. Send any updates to the quality control plan direct to the Chemical Laboratory Director.
1017.2.2 Sampling and Inspection
The Field Materials Chemist may coordinate with the manufacturer to obtain a semi-annual split sample of the approved grade of GGBFS along with a split sample of the reference cement used by the manufacturer. Properly label the sample and enter the sample information into SiteManager. Designate sample type as "Split Sample". The manufacturer shall furnish the manufacturer’s test results to the Field Materials Chemist within two weeks after completion.
1017.2.3 Disqualified Facilities
GGBFS producers that fail to comply with the qualified status as set forth in Sec 1017 will be required to designate the silo(s), bin(s), or storage facility from which they propose to furnish GGBFS for MoDOT projects. The producer must sample, test, and report satisfactory test results for each designated silo, bin, or storage facility. Prior to any shipment and following a satisfactory report furnished to the Chemical Laboratory Director, each silo, bin, or storage facility will be sampled and sealed by the Field Materials Chemist. If the results of testing by the Central Laboratory are satisfactory, the sealed silo, bin, or storage facility will be approved. This procedure will continue until adequate quality control has been re-established.
1017.2.4 Destination Inspection of Approved or Certified GGBFS
The ready-mix, precast, or paving plant operator shall furnish a copy of the bill of lading or delivery receipt for each shipment to MoDOT work.
Use the following procedure to sample GGBFS on paving jobs and at ready-mix plants. Samples shall weigh a minimum of 5 lbs (2.25 kg). Obtain samples from the storage bin or weigh hopper in one operation representing a brief period in the GGBFS stream.
Take a sample for each 375 tons (340 Mg) or portion thereof at destination for each paving job and submit to the Central Laboratory.
At ready-mix or precast plants, take a sample for each 375 tons (340 Mg) or portion thereof with a minimum of one sample every other month during the period that the ready-mix or precast plant is furnishing slag modified concrete for MoDOT work.
Place the samples taken at destination in a canvas bag containing a plastic liner and ship to the Central Laboratory. Properly label the sample and enter pertinent sample information into SiteManager. Designate the sample type "Proj – Check Sample".
1017.3 Report
Report of Central Laboratory test results on random samples of GGBFS originating from a qualified manufacturer or terminal will not be distributed unless specifically requested and conditions warrant this information for a specific purpose.
The receiving district Construction and Materials Engineer shall continuously monitor shipments to the particular ready-mix or paving plants to assure the GGBFS was shipped from an approved source.
Perform a review of each plant inspector's daily report data at regular intervals not to exceed one week. Verify that enough tickets are shown to account for the amount of GGBFS used and that the supplier and grade are shown on the list of qualified sources. If the report does not contain the required information, notify the district Construction and Materials Engineer.
1017.4 Laboratory Testing for Sec 1017
1017.4.1 Sample Preparation
Prior to testing, the sample should be thoroughly mixed, passed through a No. 20 (850 mm) sieve, and brought to room temperature. All foreign matter and lumps that do not pulverize easily in the fingers must be discarded.
1017.4.2 Procedure
Chemical analysis is to be conducted according to ASTM C114 and C989. Original test data and calculations are to be recorded in Laboratory workbooks. Test results are to be recorded in SiteManager.
Physical tests shall be conducted in accordance with the following methods:
- (a) Fineness, 325 (45 mm) sieve analysis - ASTM C430
- (b) Slag Activity Index (7 day and 28 day) - ASTM C989
- (c) Fineness, air permeability - ASTM C204
- (d) Density - ASTM C188
Original test data and calculations are to be recorded in Laboratory workbooks. Test results are to be recorded in SiteManager.
1017.4.3 Plant Inspection
Qualified GGBFS manufacturers and terminals shipping material by certification to MoDOT projects shall be inspected on a regular basis by a representative of the Laboratory. This inspection shall include a review of plant facilities for producing a quality product; plant testing procedures; frequency of tests; plant records of daily test results and shipping information; company certification procedures for silos, bins, and/or shipments; and a discussion of items of mutual interest between the plant and MoDOT. The Laboratory representative shall coordinate test results and test procedures between the Laboratory and the respective plant laboratory, and investigate associated problems.
All silo or bin certifications and results of complete physical and chemical tests received in the Laboratory are to be checked for specification compliance and to determine if the required certifications have been furnished.
1017.4.4 Sample Record
All sample records shall be completed in SiteManager, as described in Automation Section 3510, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [Reporting Test Results], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.