Category:1018 Fly Ash for Concrete
This article establishes procedures for inspecting, sampling, and accepting fly ash at the source and destination and to establish a list of qualified fly ash sources. The list of qualified sources is shown in 1018.4 Qualified Fly Ash Sources. Refer to Sec 1018 for MoDOT’s specifications.
Contents
1018.1 Apparatus
Keep all sample containers and equipment used in sampling clean and free of moisture or any foreign material. It is important that the sample be kept in airtight, moisture-proof containers from the time it is obtained until tests are started. The apparatus consists of:
- (a) Canvas bags with plastic liners.
- (b) Rubber bands for securely fastening the top of plastic liners.
- (c) Slotted tube, tube sampler, scoop or any other device suitable for obtaining the sample.
- (d) Labeling materials.
1018.2 Procedure
1018.2.1 Source Acceptance and Qualification
All fly ash for use in MoDOT projects must be furnished from a qualified marketing entity or a qualified terminal and must comply with the requirements of Sec 1018. The procedures for qualification are listed in Sec 1018. Questions from potential suppliers concerning qualification are to be directed to the Central Office. The latest copy of each marketing entity's quality control plan is to be kept on file in the Central Office. Send any updates to the quality control plan directly to the Chemical Laboratory Director.
1018.2.2 Inspection and Sampling
The Field Materials Chemist may coordinate with the marketing entity to obtain a semi-annual split sample of fly ash from each qualified source. Complete a sample record in SiteManager showing manufacturer, marketing entity, silo number, class and other pertinent information. Designate sample type as a " Split Sample". The marketing entity shall furnish test results on the split sample direct to the Field Materials Chemist within two weeks of completion.
1018.2.3 Disqualified Facilities
Fly ash marketing entities or terminals that fail to comply with the qualified status as set forth in Specification Sec 1018 will be required to designate the silo(s), bin(s), or storage facility from which they propose to furnish fly ash for MoDOT projects. The producer must sample, test, and report satisfactory test results for each designated silo, bin, or storage facility. Prior to any shipment and following a satisfactory report furnished to the Chemical Laboratory Director, each silo, bin, or storage facility will be sampled and sealed by the Field Materials Chemist. If the results of testing by the Central Laboratory are satisfactory, the sealed silo, bin, or storage facility will be approved. This procedure will continue until adequate quality control has been re-established.
1018.2.4 Destination Inspection of Approved or Certified Fly Ash
The ready-mix, precast or paving plant operators shall furnish a copy of the bill of lading or delivery receipt for each shipment to MoDOT work.
Use the following procedure to sample fly ash on paving jobs and at ready-mix plants. Samples shall weigh a minimum of 5 lb. (2.25 kg). Obtain samples from the storage bin or weigh hopper in one operation representing a brief period in the fly ash stream.
Take a sample for each 600 tons (544 Mg) or portion thereof at destination for each paving job and submit to the Laboratory.
At ready-mix or precast plants, take a sample for each 600 tons (544 Mg) or portion thereof with a minimum of one sample every other month during the period that the ready-mix or precast plant is furnishing fly ash modified concrete for MoDOT work.
Place the samples taken at destination in a canvas bag containing a plastic liner and ship to the Central Laboratory. Complete a sample record in SiteManager and show the manufacturer, marketing entity, silo or bin number, type, and other pertinent information such as contractor, plant location, and county. Designate the sample type "Proj-Check Sample".
The district is to ensure that the qualified marketing entity is certifying each shipment in accordance with Sec 1018 including all requirements for signatures and shipments from other entities.
1018.3 Report
Reports of Central Laboratory test results on random samples of fly ash originating from a qualified marketing entity will not be distributed unless specifically requested and conditions warrant this information for a specific purpose.
The receiving district Operations Engineer shall continuously monitor shipments to the particular ready-mix or paving plants to assure the fly ash was shipped from an approved source.
Perform a review of each plant's inspector's daily report at regular intervals not to exceed one week. Verify that enough tickets are shown to account for the amount of fly ash used and that the fly ash came from a qualified marketing entity.
If the report does not contain the required information, notify the district Operations Engineer.
1018.4 Qualified Fly Ash Sources
Generating Station | Marketing Entity | Terminal | Class |
---|---|---|---|
Ameren – Union Electric | Mineral Resource Tech,LLC | Labadie, MO | C |
Labadie, MO | 2700 Research Forest Dr. | ||
Suite 150 | |||
The Woodlands, TX 77381 | |||
Ameren – Union Electric | Mineral Resource Tech,LLC | Riverview Terminal | C |
Labadie, MO | 2700 Research Forest Dr. | St. Louis, MO | |
Suite 150 | |||
The Woodlands, TX 77381 | |||
Ameren – Union Electric | Mineral Resource Tech,LLC | Festus, MO | C |
(Rush Island Power Plant) | 2700 Research Forest Dr. | ||
Festus, MO | Suite 150 | ||
The Woodlands, TX 77381 | |||
Ameren – Union Electric | Mineral Resource Tech,LLC | Riverview Terminal | C |
(Rush Island Power Plant) | 2700 Research Forest Dr. | St. Louis, MO | |
Festus, MO Suite 150 | |||
The Woodlands, TX 77381 | |||
Ash Grove Cement Co. | Ash Grove Cement Company | Chanute, KS | F |
Chanute, KS Plant | 11011 Cody | ||
Overland Park, KS 66210 | |||
Associated Electric Cooperative, Inc. | Headwaters Resources | Thomas Hill, MO | C |
Bay City, MI 46706 | |||
(Thomas Hill Power Plant) | |||
Thomas Hill, MO | |||
Board of Public Utilities | Lafarge North America | Kansas City, KS | C |
(Nearman Creek Power Station) | 20408 W. Renwick Rd. | ||
Kansas City, KS | Lockport, IL 60441 1 | ||
Boral Material Technologies | Ash Grove Cement Company | Chanute, KS | F |
(Monticello Plant) | 11011 Cody | ||
Mt. Pleasant TX (2/05) | Overland Park, KS 66210 | ||
City Utilities | Headwaters Resources | Springfield, MO | C |
(James River Power Station) | Bay City, MI 48706 | ||
Springfield, MO | |||
(7/04) | |||
Dynegy | Headwaters Resources | Baldwin, IL | C |
(Baldwin Power Plant) | 4043 N. Euclid Ave | ||
Baldwin, IL | Bay City, MI 48706 | ||
Dynegy | Headwaters Resources | Alton, IL | C |
(Wood River Power Station) | Bay City, MI 48706 | ||
Alton, IL | |||
Electric Energy, Inc. | Mineral Resource Tech, LLC | Joppa, IL | C |
(Joppa Station) | 2700 Research Forest Dr. | ||
Joppa, IL | Suite 150 | ||
The Woodlands, TX 77381 | |||
Grand River | Mineral Resource Tech, LLC | Chouteau, OK | C |
Dam Authority 2700 | Research Forest Dr. | ||
(GRDA) | Suite 150 | ||
Chouteau, OK | The Woodlands, TX 77381 | ||
Jeffrey Energy Center | Ash Grove Resources | Chanute, KS | C |
St. Mary’s, KS | 1520 SW 41st Street | ||
(3/05) | Topeka, KS 66609 | ||
Jeffrey Energy Center | Ash Grove Resources | St. Mary’s, KS | C |
St. Mary’s, KS | 1520 SW 41st Street | ||
(9/06) | Topeka, KS 66609 | ||
Jeffrey Energy Center | Ash Grove Resources | Edwardsville, KS | C |
St. Mary’s, KS | 1520 SW 41st Street | ||
Topeka, KS 66609 | |||
Kansas City Power & Light | Lafarge North America | Iatan, MO | C |
(Iatan Station) | 20408 W. Renwick Rd. | ||
Iatan, MO | Lockport, IL 60441 | ||
Kansas City Power & Light | Lafarge North America | LaCygne, KS | C |
(LaCygne Station) | 20408 W. Renwick Rd. | ||
LaCygne, KS | Lockport, IL 60441 | ||
Mid America Energy | Headwaters Resources | Council Bluffs, IA | C |
Council Bluffs Power Plant | Bay City, MI 48706 | ||
Council Bluffs, IA | |||
Kansas City Power & Light | Lafarge North America | LaDue, MO | C |
(Monstrose Station) | 20408 W. Renwick Rd. | ||
LaDue, MO | Lockport, IL 60441 | ||
(5/04) | |||
Oklahoma Gas & Electric | Lafarge North America | Fort Gibson, OK | C |
(Muskogee Generating Station) | 20408 W. Renwick Rd. | ||
Fort Gibson, OK | Lockport, IL 60441 | ||
(12/03) | |||
Omaha Public Power District | Ash Grove Resources | Nebraska City | C |
Nebraska City Plant | 1520 SW 41st | ||
Nebraska City, NE | Topeka, KS 66609 | ||
(4/02) | |||
Omaha Public Power District | Ash Grove Resources | Bonner Springs, KS | C |
Nebraska City Plant | 1520 SW 41st | ||
Nebraska City, NE | Topeka, KS 66609 | ||
(4/02) | |||
Sikeston, Board of | Headwaters Resources | Sikeston, MO | C |
(Sikeston Power Plant) | Bay City, MI 48706 | ||
Sikeston, MOSWEPCO | Mineral Resource Tech, LLC | Gentry, AR | C |
Flint Creek Power Station | 2700 Research Forest Dr. | ||
Gentry, AR | Suite 150 | ||
(10/99) | The Woodlands, TX 77381 | ||
Tecumseh Energy Center | Ash Grove Resources | Tecumseh, KS | C |
Tecumseh, KS | 1520 SW 41st Street | ||
(3/05) | Topeka, KS 66609 | ||
1 Class C fly ash utilized solely for soil stabilization |