Difference between revisions of "616.10 Product Requirements for Temporary Traffic Control Devices, Pavement Marking and Delineation"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (slight numbering revision)
m (Per TS and DE, article's content greatly reduced since current info is seldom used. Deemed more accurate to simply point the reader to the specs.)
Tag: Replaced
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
'''1)''' Contractor or manufacturer shall provide a letter of certification stating the device is crashworthy.
+
[[image:106.17.jpg|right|625px]]
 +
Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 616 and Sec 1063] for MoDOT’s specifications.
  
'''2)''' Contractor or manufacturer shall provide a copy of the FHWA acceptance letter for the device as proof of crashworthiness and a letter certifying the device has essentially the same chemistry, mechanical properties and geometry as that submitted for acceptance.
 
  
'''3)''' Contractor or manufacturer shall provide a letter of certification stating the device meets MoDOT specifications and standards. Certifications shall identify specific sheeting products used in fabrication of the item.
 
 
'''4)''' Qualified lists direct which products have been found acceptable for use on MoDOT projects and is not an inclusive listing. Products not listed may be found acceptable for use based on certification.
 
 
{| border="1" class="wikitable" style="text-align:center"
 
|+
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
| - || - || - ||REFLECTIVE SHEETINGS FOR DELINEATORS ||1042|| - || - || - || - || - || X|| X ||Qualified List is located in [[106.1 Source of Supply and Quality Requirements#Materials|EPG 106.1 Source of Supply and Quality Requirements]]
 
|-
 
| - || - || - ||REFLECTIVE SHEETINGS FOR TTCD ||1063 || - || - || - || - || - || X|| X ||Qualified List is located in [[106.1 Source of Supply and Quality Requirements#Materials|EPG 106.1 Source of Supply and Quality Requirements]]
 
|-
 
! style="background:#BEBEBE" colspan="13"| 606 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|606-30.17|| 1.00|| EACH||TYPE C CRASHWORTHY END TERMINAL|| 606, 1040||  - || - ||3|| - || X|| X|| X|| Qualified List is located in [[106.1 Source of Supply and Quality Requirements#Materials|EPG 106.1 Source of Supply and Quality Requirements]], description is at [[:category:1040 Guardrail, End Terminals, One-Strand Access Restraint Cable and Three-Strand Guard Cable Material#1040.4 Crashworthy End Terminal and Qualified Plastic Guardrail Block|EPG 1040.4]].
 
|-
 
|606-XX.XX|| 1.00|| EACH ||WATER-FILLED END TREATMENTS || - || - || - ||3 || - ||X || - || - || Qualified List is located in [[106.1 Source of Supply and Quality Requirements#Materials|EPG 106.1 Source of Supply and Quality Requirements]].
 
|-
 
|606-66.4X|| 1.00|| EACH ||GUARDRAIL DELINEATOR||606, 1065,1042|| 606|| - || - || - || - || X|| - || -
 
|-
 
|606-66.4X|| 1.00|| EACH GUARD ||CABLE DELINEATOR ||606, 1065,1042|| 606|| - || - || - || - || X|| - || -
 
|-
 
! style="background:#BEBEBE" colspan="13"| 612 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|612-20.XX|| 1.00|| EACH ||IMPACT ATTENUATOR||612, 1005,1063 ||612|| - || 3|| - || X|| X|| X|| Qualified List is located in [[106.1 Source of Supply and Quality Requirements#Materials|EPG 106.1 Source of Supply and Quality Requirements]], description is at [[:Category:1040 Guardrail, End Terminals, One-Strand Access Restraint Cable and Three-Strand Guard Cable Material#1040.4 Crashworthy End Terminal, Qualified Plastic Guardrail Block and Three-Strand Guard Cable System Tables|EPG 1040.4]].
 
|-
 
|612-30.00|| 1.00|| EACH ||TRUCK-MOUNTED ATTENUATOR ||612, 1063|| - || - ||3||  - ||X|| X|| - || -
 
|-
 
! style="background:#BEBEBE" colspan="13"| 616 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|rowspan="6"|616-10.05|| rowspan="6"| 1.00|| rowspan="6"|SQ.FT.|| CONSTRUCTION SIGNS|| 616, 1063|| 616|| - || -|| -|| -|| X|| -|| -
 
|-
 
|U-CHANNEL POST, 3 LB|| 616, 903||616,903|| - || -|| -|| -|| X || -||Galvanization is not required.
 
|-
 
|WOOD POST, X IN. BY X IN. ||616, 903||616,903|| - || -|| -|| -|| X|| -|| -
 
|-
 
|PERFORATED SQUARE STEEL TUBE POST AND ANCHOR SLEEVE|| 616, 903||616,903|| - || -|| -|| -|| X || -||Galvanization is not required.
 
|-
 
|TYPE 1 PORTABLE ||616|| 616|| - || 2 || - ||X ||X|| - ||Sign substrate used should be consistent with the acceptance and certification letter.
 
|-
 
|TYPE 2 PORTABLE ||616|| 616|| -|| 2|| -|| X|| X|| -||Sign substrate used should be consistent with the acceptance and certification letter.
 
|-
 
|616-10.07 ||1.00 ||EACH||SPEED LIMIT AND STROBE LIGHT ASSEMBLY|| 616, 1063 ||616|| - || -|| -|| -|| X|| -|| -
 
|-
 
|616-10.08 ||1.00 ||EACH||ADVANCED WARNING RAIL SYSTEM|| 616, 1063 ||616|| - || -|| -|| -|| X|| -|| -
 
|-
 
|616-10.09 ||1.00 ||EACH||FLAG ASSEMBLY|| 616, 1063 ||616|| - || -|| -|| -|| X|| -|| -
 
|-
 
|616-10.20|| 1.00|| EACH ||CHANNELIZER (DRUM-LIKE)|| 616, 1063|| 616|| -||1|| X|| -||X|| - || -
 
|-
 
|616-10.21|| 1.00|| EACH ||CHANNELIZER (DRUM-LIKE) W/LIGHT|| 616, 1063|| 616|| - || 1|| X|| - || X|| - || -
 
|-
 
| rowspan="2"|616-10.25 || rowspan="2"|1.00|| rowspan="2"| EACH ||CHANNELIZER (TRIM-LIKE)|| 616, 1063|| 616|| - || 1|| X|| - || X|| - || -
 
|-
 
|CHANNELIZER (CONES)|| 616, 1063|| 616|| - || 1|| X|| - || X|| - || -
 
|-
 
|616-10.30|| 1.00|| EACH|| TYPE III MOVEABLE BARRICADE|| 616, 1063|| 616|| - || 2|| - || X|| X|| - || -
 
|-
 
|616-10.30|| 1.00|| EACH||TYPE III MOVEABLE BARRICADE W/LIGHT AND/OR SIGN ||616, 1063|| 616 || - ||2 || - ||X|| X|| - || -
 
|-
 
|616-10.33|| 1.00|| EACH||DIRECTIONAL INDICATOR BARRICADE ||616, 1063|| 616|| - || 2|| - || X|| X|| - || -
 
|-
 
|616-10.34|| 1.00|| EACH||DIRECTIONAL INDICATOR BARRICADE W/LIGHT|| 616, 1063|| 616|| - || 2|| - || X|| X|| - || -
 
|-
 
|616-10.40|| 1.00|| EACH ||FLASHING ARROW PANEL|| 616, 1063|| 616|| - || 4|| - || - || X|| - || -
 
|-
 
|616-10.47|| 1.00|| EACH ||TYPE III OBJECT MARKER ||616, 1063 ||616|| - || -|| -|| -|| X|| - || -
 
|-
 
|616-10.51|| 1.00|| EACH ||WARNING LIGHT, TYPE A ||616|| 616 || - || -|| -|| -|| X|| - || -
 
|-
 
|616-10.52|| 1.00|| EACH ||WARNING LIGHT, TYPE B|| 616|| 616|| - || -|| -|| -|| X||-
 
|| -
 
|-
 
|616-10.53|| 1.00|| EACH ||WARNING LIGHT, TYPE C|| 616|| 616|| - || -|| -|| -|| X|| - || -
 
|-
 
|616-10.70 ||1.00|| EACH ||TUBULAR MARKER ||616, 1063|| 616 || - ||1 ||X || - || X|| - || -
 
|-
 
|616-10.95|| 1.00|| EACH ||[[616.3 Changeable Message Signs (CMS)#Radar Speed Advisory Assembly|RADAR SPEED ADVISORY SYSTEM]]|| 616, 1063|| - || - || 4|| - || - || X|| - || -
 
|-
 
|616-10.98|| 1.00|| EACH||[[616.3 Changeable Message Signs (CMS)|CHANGEABLE MESSAGE SIGN]]|| 616, 1063|| 616|| - || 4|| - || - || X|| - || -
 
|-
 
|616-11.00|| 1.00|| EACH||CHANGEABLE MESSAGE SIGN, CONTRACTOR FURNISHED,COMMISSION RETAINED|| 616, 1063|| 616|| - || 4|| - || - || X|| X|| -
 
|-
 
|616-20.00|| 1.00|| EACH||WORK ZONE TRAFFIC SIGNALS (PORTABLE OR TEMPORARY SPAN)|| 616, 1063|| - || -|| 4 for trailer|| - || -|| X|| - || -
 
|-
 
| rowspan="2"|616-20.10||  rowspan="2"|1.00||  rowspan="2"|LUMP SUM ||WORK ZONE LIGHTING|| 616|| - || -|| 4 for trailer|| - || - || X|| - || Lighting Plans are Required
 
|-
 
|VERTICAL PANELS || - || -||  -|| 2|| -|| X || - || -|| Experimental Basis
 
|-
 
! style="background:#BEBEBE" colspan="13"| 617 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|617-36.XX|| 1.00||LINEAR FT||TEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/RETAINED (ALL COMBINATIONS)||617, 1064, 1065 ||617|| - || 3|| -||  -||  X|| - ||Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
 
|-
 
|617-36.XX ||1.00||LINEAR FT||TEMPORARY CONCRETE TRAFFIC BARRIER, TYPE F, CONTRACTOR FURNISHED/COMMISSION RETAINED (ALL COMBINATIONS)||617, 1064, 1065 ||617|| - || 3|| -||  -||  X|| - ||Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
 
|-
 
|617-40.00|| 1.00|| EACH||TEMPORARY CONCRETE BARRIER HEIGHT TRANSITION||617, 1064,1065 ||617|| -|| 3|| -||  -|| X|| - ||Certification is required for delineator sheeting. The individual barriers shall be permanently marked according to specifications.
 
|-
 
|617-80.0X|| 1.00|| EACH ||TRAFFIC BARRIER DELINEATOR||617, 1065,1042 ||617|| -||  -|| -||  -|| X|| -||  -
 
|-
 
|617-XX.XX|| -||  -|| WATER FILLED BARRIER || -||  -|| - ||3 || - ||X|| -||  -|| -
 
|-
 
|617-XX.XX || -||  -||TEMPORARY GLARE SCREENS|| -||  -|| -||  -|| -||  -|| -||  -|| -
 
|-
 
! style="background:#BEBEBE" colspan="13"| 620 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|620-XX.XX|| 1.00||LINEAR FT OR EACH|| TYPE 1 PREFORMED TAPE ||620, 1048|| 620|| -||  -|| -||  -|| X|| X|| -
 
|-
 
|620-51.XX|| 1.00||LINEAR FT OR EACH ||TYPE 2 PREFORMED TAPE|| 620, 1048|| 620|| -||  -|| -||  -||  X|| X|| -
 
|-
 
|620-53.XX|| 1.00||LINEAR FT|| PREFORMED REMOVABLE MARKING TAPE|| 620, 1048 ||620|| -||  -|| -||  -||  X|| X|| -
 
|-
 
|620-53.XX ||1.00||LINEAR FT OR EACH||PREFORMED SHORT TERM MARKING TAPE ||620, 1048|| 620 || -||  -|| -||  -|| X|| X|| -
 
|-
 
|620-59.XX ||1.00||LINEAR FT||HIGH BUILD ACRYLIC WATERBORNE PAVEMENT MARKING PAINT ||620, 1048|| 620|| -||  -|| -||  -|| X|| X|| -
 
|-
 
|620-6X.XX|| 1.00||LINEAR FT OR EACH||ACRYLIC WATERBORNE PAVEMENT MARKING PAINT ||620, 1048 ||620|| -||  -|| -||  -|| X|| X||Being phased out due to the use of high build acrylic waterborne pavement marking paint.
 
|-
 
|620-6X.XX||1.00||LINEAR FT OR EACH||ACRYLIC COPOLYMER FAST DRY PAVEMENT MARKING PAINT|| 620, 1048 ||620|| -||  -|| -||  -|| X ||X|| -
 
|-
 
|620-62.XX||1.00||LINEAR FT OR EACH||TYPE A EPOXY PAVEMENT MARKING|| 620, 1048|| 620|| -||  -|| -||  -|| X ||X|| -
 
|-
 
|620-63.XX ||1.00||LINEAR FT OR EACH||TYPE B EPOXY PAVEMENT MARKING ||620, 1048|| 620|| -||  -|| -||  -|| X ||X || -
 
|-
 
|620-80.64|| 1.00|| EACH||TEMPORARY RAISED PAVEMENT MARKER, TYPE 1|| 620, 1048|| 620 || -||  -|| -||  -|| X|| X|| -
 
|-
 
| rowspan="3"|620-80.65|| rowspan="3"|1.00 || rowspan="3"|EACH||TEMPORARY RAISED PAVEMENT MARKER, TYPE 2|| 620, 1048|| 620 || -||  -|| -||  -|| X|| X|| -
 
|-
 
|DROP-ON GLASS BEADS ||620, 1048|| - || - || - || - || - || X|| X|| -
 
|-
 
|CURB SYSTEMS || - || - || - ||2|| - || X|| - || - || -
 
|-
 
! style="background:#BEBEBE" colspan="13"| 902 Items
 
|-
 
! style="background:#BEBEBE" rowspan="2"| Item No. !! style="background:#BEBEBE" rowspan="2"| Unit !! style="background:#BEBEBE" rowspan="2"| Type !! style="background:#BEBEBE" rowspan="2"| Item Description !! style="background:#BEBEBE" rowspan="2"| Sec !! style="background:#BEBEBE" rowspan="2"| Std. Plan!! style="background:#BEBEBE" rowspan="2"| JSP !! style="background:#BEBEBE" rowspan="2"| NCHRP 350 TL-3 Category Number !! style="background:#BEBEBE" colspan="3"|Certification Requirements !!style="background:#BEBEBE" rowspan="2"| Qual. List (4) !!style="background:#BEBEBE" rowspan="2"| Comments
 
|-
 
!style="background:#BEBEBE"|Crashworthiness (1) !! style="background:#BEBEBE"| FHWA Acceptance Letter (2) !! style="background:#BEBEBE"| Spec and Stnd (3)
 
|-
 
|902-94.12|| 1.00|| EACH||WORK ZONE TRAFFIC SIGNALS (PORTABLE), CONTRACTOR FURNISHED, COMMISSION RETAINED ||616, 1063|| - || - ||4|| - || - ||X ||X|| -
 
|}
 
 
 
[[image:106.17.jpg|left|825px]]
 
  
 
[[Category:616 Temporary Traffic Control]]
 
[[Category:616 Temporary Traffic Control]]

Latest revision as of 15:04, 7 October 2020

106.17.jpg