Difference between revisions of "Category:1027 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (article construction)
m (→‎1027.4.2 Sample Record: Per CM, replaced archaic "Automation Section" with AWP MA Sample Record, General)
 
(9 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
|'''Approved and Pre-Qualified List'''
 
|'''Approved and Pre-Qualified List'''
 
|-
 
|-
|[http://www.modot.mo.gov/business/materials/pdf/vol_1/FS1027T1.pdf QC/QA Polymer-Coated Corrugated Metal Culvert Pipe]
+
|[https://www.modot.org/media/487 QC/QA Polymer-Coated Corrugated Metal Culvert Pipe]
 
|-
 
|-
 
|'''MGS Information'''
 
|'''MGS Information'''
 
|-
 
|-
|[http://www.modot.mo.gov/business/materials/pdf/mgs/MGSINDEX.pdf Current General Services Specifications (MGS) By Subject]  
+
|[https://www.modot.org/general-services-specifications-mgs-subject Current General Services Specifications (MGS) By Subject]  
 
|}
 
|}
  
  
This article establishes procedures for inspecting, acceptance and reporting of polymer-coated corrugated metal culvert pipe and pipe arches. Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1027.pdf Sec 1027] for MoDOT’s specifications.
+
This article establishes procedures for inspecting, acceptance and reporting of polymer-coated corrugated metal culvert pipe and pipe arches. Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1027] for MoDOT’s specifications.
  
For Laboratory testing and sample reporting procedures, refer to [[:Category:1027 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches#1027.4 Laboratory Testing Guidelines for Sec 1027|1027.4 Laboratory Testing Guidelines for Sec 1027]].  
+
For Laboratory testing and sample reporting procedures, refer to [[:Category:1027 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches#1027.4 Laboratory Testing Guidelines for Sec 1027|EPG 1027.4 Laboratory Testing Guidelines for Sec 1027]].  
  
 
==1027.1 Apparatus==
 
==1027.1 Apparatus==
Line 28: Line 28:
  
 
===1027.2.1 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches===
 
===1027.2.1 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches===
Polymer-coated corrugated metal culvert pipe and pipe arch is to be accepted in accordance with [http://www.modot.mo.gov/business/standards_and_specs/Sec1027.pdf Sec 1027.2].
+
Polymer-coated corrugated metal culvert pipe and pipe arch is to be accepted in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1027.2].
  
 
===1027.2.2 Material===
 
===1027.2.2 Material===
The pipe shall be in accordance [http://www.modot.mo.gov/business/standards_and_specs/Sec1020.pdf Sec 1020] and
+
The pipe shall be in accordance [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1020] and
[http://www.modot.mo.gov/business/standards_and_specs/Sec1027.pdf Sec 1027]. The polymer material shall be in accordance with AASHTO M 245.
+
[http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1027]. The polymer material shall be in accordance with AASHTO M 245.
  
 
===1027.2.3 Identification Markings===
 
===1027.2.3 Identification Markings===
Line 39: Line 39:
 
===1027.2.4 Random Sampling===
 
===1027.2.4 Random Sampling===
 
Random samples are to be taken in as described in
 
Random samples are to be taken in as described in
[[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.4 Random Sampling of Steel Sheet|1020.2.4 Random Sampling of Steel Sheet]]. Random samples of polymer coating are to be taken as described in AASHTO
+
[[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.4 Random Sampling of Steel Sheet|EPG 1020.2.4 Random Sampling of Steel Sheet]]. Random samples of polymer coating are to be taken as described in AASHTO
 
M 245.
 
M 245.
  
Line 45: Line 45:
  
 
===1027.2.5 Field Inspection===
 
===1027.2.5 Field Inspection===
Field inspection shall be performed in accordance with and at the frequency specified in [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.5 Field Inspection|1020.2.5 Field Inspection]].
+
Field inspection shall be performed in accordance with and at the frequency specified in [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.5 Field Inspection|EPG 1020.2.5 Field Inspection]].
  
 
===1027.2.6 Fabrication===
 
===1027.2.6 Fabrication===
Fabrication of polymer coated corrugated metal culvert pipe and pipe-arch shall be in accordance with [http://www.modot.mo.gov/business/standards_and_specs/Sec1020.pdf Sec 1020] and AASHTO M 245.
+
Fabrication of polymer coated corrugated metal culvert pipe and pipe-arch shall be in accordance with [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1020] and AASHTO M 245.
  
 
===1027.2.7 Repair of Damaged Coating===
 
===1027.2.7 Repair of Damaged Coating===
Units on which the metallic coating has been damaged shall be repaired as described in [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.7.2 Repair of Damaged Coating|1020.2.7.2 Repair of Damaged Coating]]. Polymer coating shall be repaired as described in AASHTO M 245.
+
Units on which the metallic coating has been damaged shall be repaired as described in [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.2.7.2 Repair of Damaged Coating|EPG 1020.2.7.2 Repair of Damaged Coating]]. Polymer coating shall be repaired as described in AASHTO M 245.
  
 
==1027.3 Sample Record==
 
==1027.3 Sample Record==
 
Sample ID’s shall be assigned and sample records shall be created in accordance with [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.3 Sample Record|1020.3 Sample Record]].
 
Sample ID’s shall be assigned and sample records shall be created in accordance with [[:category:1020 Corrugated Metallic-Coated Steel Culvert Pipe, Pipe-Arches and End Sections#1020.3 Sample Record|1020.3 Sample Record]].
  
==1027.4 Laboratory Testing Guidelines for [http://www.modot.mo.gov/business/standards_and_specs/Sec1027.pdf Sec 1027]==
+
==1027.4 Laboratory Testing Guidelines for [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1027]==
  
 
This article establishes procedures for Laboratory testing and reporting samples of
 
This article establishes procedures for Laboratory testing and reporting samples of
Line 62: Line 62:
  
 
===1027.4.1 Procedure===
 
===1027.4.1 Procedure===
Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through SiteManager.
+
Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP).
  
 
===1027.4.2 Sample Record===
 
===1027.4.2 Sample Record===
The sample record shall be completed in SiteManager, as described in [[Automation Sec 3510]], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.9 Reporting Test Results|106.9 Reporting Test Results]], are to be included in the sample record to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
+
The sample record shall be completed in AWP, as described in [https://epg.modot.org/forms/CM/AWP_MA_Sample_Record_General.docx AWP MA Sample Record, General], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the sample record to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.

Latest revision as of 09:19, 24 November 2021

Approved and Pre-Qualified List
QC/QA Polymer-Coated Corrugated Metal Culvert Pipe
MGS Information
Current General Services Specifications (MGS) By Subject


This article establishes procedures for inspecting, acceptance and reporting of polymer-coated corrugated metal culvert pipe and pipe arches. Refer to Sec 1027 for MoDOT’s specifications.

For Laboratory testing and sample reporting procedures, refer to EPG 1027.4 Laboratory Testing Guidelines for Sec 1027.

1027.1 Apparatus

(a) Magnetic or electronic gauge, reading range 0-40 mils (0-1000 μm).

(b) Micrometer capable of measuring to 0.0001 in. (0.00254 mm) and accurate to within at least 0.001 in. (0.0254 mm).

(c) Rule with suitable gradations to accurately measure the material to be inspected.

(d) The Corrugated Metal Pipe (CMP) Inspection Guide.

1027.2 Procedure

1027.2.1 Polymer-Coated Corrugated Metal Culvert Pipe and Pipe-Arches

Polymer-coated corrugated metal culvert pipe and pipe arch is to be accepted in accordance with Sec 1027.2.

1027.2.2 Material

The pipe shall be in accordance Sec 1020 and Sec 1027. The polymer material shall be in accordance with AASHTO M 245.

1027.2.3 Identification Markings

Pipe is to be marked in as described in 1020.2.3 Identification Markings for Steel Sheet.

1027.2.4 Random Sampling

Random samples are to be taken in as described in EPG 1020.2.4 Random Sampling of Steel Sheet. Random samples of polymer coating are to be taken as described in AASHTO M 245.

Samples for determination of coating thickness may be taken from fabricated pipe.

1027.2.5 Field Inspection

Field inspection shall be performed in accordance with and at the frequency specified in EPG 1020.2.5 Field Inspection.

1027.2.6 Fabrication

Fabrication of polymer coated corrugated metal culvert pipe and pipe-arch shall be in accordance with Sec 1020 and AASHTO M 245.

1027.2.7 Repair of Damaged Coating

Units on which the metallic coating has been damaged shall be repaired as described in EPG 1020.2.7.2 Repair of Damaged Coating. Polymer coating shall be repaired as described in AASHTO M 245.

1027.3 Sample Record

Sample ID’s shall be assigned and sample records shall be created in accordance with 1020.3 Sample Record.

1027.4 Laboratory Testing Guidelines for Sec 1027

This article establishes procedures for Laboratory testing and reporting samples of nonreinforced concrete culvert, storm drain and sewer pipe.

1027.4.1 Procedure

Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP).

1027.4.2 Sample Record

The sample record shall be completed in AWP, as described in AWP MA Sample Record, General, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the sample record to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.