751.9 Bridge Seismic Design

From Engineering_Policy_Guide
Jump to navigation Jump to search

Contents

751.9.1 Seismic Analysis and Design Specifications

Additional Information

All new or replacement bridges on the state system shall include seismic design and/or detailing to resist an expected seismic event per the Bridge Seismic Design Flowchart. For example, for a bridge in Seismic Design Categories A, B, C or D, complete seismic analysis or seismic detailing only may be determined as per “Bridge Seismic Design Flowchart”.

Missouri is divided into four Seismic Design Categories. Most of the state is SDC A which requires minimal seismic design and/or detailing in accordance with SGS (Seismic Zone 1 of LRFD) and “Bridge Seismic Design Flowchart”. The other seismic design categories will require a greater amount of seismic design and/or detailing.

For seismic detailing only:

When AS is greater than 0.75 then use AS = 0.75 for abutment design where required per “Bridge Seismic Design Flowchart” and SEG 24-01

For complete seismic analysis:

When AS is greater than 0.75 then use AS = 0.75 at zero second for seismic analysis and response spectrum curve. See Example 1_SDC_Response_Spectra. The other data points on the response spectrum curve shall not be modified.

Additional Information

When existing bridges are identified as needing repairs or maintenance, a decision on whether to include seismic retrofitting in the scope of the project shall be determined per the “Bridge Seismic Retrofit Flowchart”, the extent of the rehabilitation work and the expected life of the bridge after the work. For example, if the bridge needs painting or deck patching, no retrofitting is recommended. However, redecking or widening the bridge indicates that MoDOT is planning to keep the bridge in the state system with an expected life of at least 30 more years. In these instances, the project core team should consider cost effective methods of retrofitting the existing bridge. Superstructure replacement requires a good substructure and the core team shall decide whether there is sufficient seismic capacity. Follow the design procedures for new or replacement bridges in forming logical comparisons and assessing risk in a rational determination of the scope of a superstructure replacement project specific to the substructure. For example, based on SPC and route, retrofit of the substructure could include seismic detailing only or a complete seismic analysis may be required determine sufficient seismic capacity. Economic analysis should be considered as part of the decision to re-use and retrofit, or re-build. Where practical, make end bents integral and eliminate expansion joints.

Bridge seismic retrofit shall be in accordance with Bridge Seismic Retrofit Flowchart. Seismic isolation systems shall conform to AASHTO Guide Specifications for Seismic Isolation Design 4th Ed. 2023.

751.9.1.1 Applicability of Guidelines and Seismic Design Philosophy

SGS 3.1, 3.2, LRFD 3.4 and LRFD C3.4.1

EPG 751.9 supplements the above documentation for typical bridges in accordance with SGS 3.1. It does not apply to movable bridges, bridges with spans greater than 500 ft., suspension bridges, cable-stayed bridges, truss bridges or arch-type bridges. The State Bridge Engineer shall specify and/or approve appropriate provisions or specifications for non typical bridges. There are special considerations for single-span bridges, temporary bridges and bridges with stage construction.

Critical and Recovery Bridges are not specifically addressed in SGS specification, SGS 3.1. Operational classification shall be in accordance with SGS 3.1 and SGS 3.2. Bridges shall be designed for the life safety performance objective using at a minimum the limit state of incipient collapse or unacceptable performance for geotechnical failure modes at a targeted risk of approximately 1.5 percent over 75 years in accordance with SGS 3.2 Higher levels of performance, such as the operational objective, may be established and authorized by the bridge owner. Critical and Recovery bridges shall be designed in accordance with AASHTO Guidelines for Performance-Based Seismic Design of Highway Bridges, 1st ed.

The following categories are used throughout EPG:

Nonseismic = Bridges requiring a static design only. Minimal seismic details in accordance with SDC A are still required.
Seismic Details = This category refers to SDC A (SD1 ≥ 0.1), B, C and D bridges that do not require a seismic design, but do require higher levels of seismic detailing.
Complete Seismic Analysis = Bridges requiring a full seismic analysis. SDC C or D bridges may be applicable based on the importance of the route.

Life safety for the design event shall be taken to imply that the bridge has a low probability of collapse but may suffer significant damage, and significant disruption to service is possible. Partial or complete replacement may be required in accordance with SGS 3.2. Hazard to human life should be minimized, and essential bridges should continue to function after an earthquake. Bridges are designed for good ductility and displacement control and are allowed to suffer minor, acceptable damage in order to prevent major, unacceptable damage.

Note: For seismic design force concepts and guidance, follow the seismic design process (EPG 751.9.1.3 thru 751.9.4) and modify design/details of LFD as necessary to meet SGS and LRFD seismic requirements until LRFD seismic section is created (modified EPG 751.9.1.3 thru 751.9.4).

All new or replacement bridges on the state system shall include seismic design and/or detailing to resist an expected seismic event (seismic design category) per the Bridge Seismic Design Flowchart.

  • For a major bridge, the State Bridge Engineer will decide the design as a life safety or critical/essential or recovery bridge in accordance with SGS 3.1, SGS 3.2 and SGS C3.2.
  • Except for section 7 of the AASHTO Guide Specifications for LRFD Seismic Bridge Design (SGS) is based on Displacement Based Design. The AASHTO LRFD Bridge Design Specifications (LRFD) is based on Force Based Design. For seismic details and design concept use the SGS when information is available otherwise use LRFD. Seismic analysis shall be performed using displacement-based design (for exception see SGS 7).
Seismic Design Category/Seismic Zone by Code
Value of design spectral acceleration
coefficient at 1.0 second period,
SD1 SGS 3.4.1 and 3.5
1AASHTO Guide Specifications
for LRFD Seismic Bridge Design (SGS)
SGS table 3.5-1
Seismic Design Category (SDC)
2AASHTO LRFD
Bridge Design Specifications (LRFD)
LRFD Table 3.10.6-1
Seismic Zones
SD1 < 0.10 A1 1
0.10 ≤ SD1 < 0.15 A23 13
0.15 ≤ SD1 < 0.30 B 2
0.30 ≤ SD1 < 0.50 C 3
0.50 ≤ SD1 D 4

1SGS is required for seismic design. LRFD is shown because SGS refers to LRFD for support, and understanding the equivalency category and zone may be important. In accordance with SGS, all bridge designs must meet the requirements for SDC A (Seismic Zone 1). Additional seismic details are typically required for higher seismic design categories.

2LRFD inequalities are different. Use SGS as shown.

3Structural member shall be detailed in accordance with SDC B (SGS 8.2) if bridge carry a 1st or 2nd priority earthquake emergency route.

751.9.1.2

(This article is not being used)

751.9.1.3 Seismic Design Force Concepts

As shown in Fig. 751.9.1.3.1(a), a two span bridge can be modeled as a single–degree-of-freedom lumped-mass system (Fig. 751.9.1.3.1(b)). For a single degree-of-freedom lumped-mass system, the total elastic seismic design force is equal to

F = m x cs x g

where:

m is the total structural mass
cs is the elastic seismic response coefficient
g is the gravitational acceleration constant

The elastic seismic response coefficient is given by the dimensionless formula

AASHTO Div. I-A, Equation 3-1

where:

A = the acceleration coefficient on rock from AASHTO Division I-A, Article 3.2; the acceleration coefficients for Missouri are shown in Fig. 751.9.1.3.3.
S = the dimensionless coefficient for the soil profile characteristics of the site as given in Article 3.5. S = 1.0, 1.2, 1.5, and 2.0 for soil profile type I, II, III, and IV respectively.
T = the fundamental period of the bridge,
where: k is the structural lateral stiffness
m is the structural mass
Fig. 751.9.1.3.1 Single-Degree-of-Freedom Lumped-Mass System; (a) Two-Span Bridge, (b) Bridge Structural Model

The elastic design acceleration spectra shown in Fig. 751.9.1.3.2 is a plot of structural period T versus the maximum acceleration quantity of the structure. For example: a bridge with the foundation period T1 is subjected to an earthquake having a rock acceleration of . The maximum acceleration of this bridge during the whole seismic excitation will be (see Fig. 751.9.1.3.2).

Fig. 751.9.1.3.2 Elastic Design Acceleration Spectrum

From Fig. 751.9.1.3.1, it can be seen that the acceleration of soil is larger than the acceleration of rock by an amplification factor S. Soil type is important to the evaluation of ground acceleration. From Figs. 751.9.1.3.1 and 751.9.1.3.2, stated briefly, the design acceleration spectrum is a plot of the maximum acceleration to a specified seismic load for all possible single degree-offreedom systems.

Using the above mentioned concept, AASHTO considers four analysis procedures to calculate elastic earthquake design force for the Multiple Degree of Freedom (MDOF) System in order of increasing complexity. Theses are:

Procedure 1 – Uniform Load Method
Procedure 2 – Single-Mode Spectral Method
Procedure 3 – Multi-Mode Spectral Method
Procedure 4 – Time History Method

MoDOT practice is to use the Multi-Mode Method for all bridges, because the Uniform Load and Single-Mode Methods are inadequate for irregular bridges and the Time History Method requires an excessive level of numerical integration time and time history records being used. A seismic structural analysis program, such as SEISAB, performs a linear elastic multi-mode response spectrum analysis, accounting also for inertial effects, damping, and modal combination, and determines seismic forces and displacements at individual joints and members.

In the Multi-mode Spectral Method, the seismic deign force, P, of a specific structural component can be calculated by taking the square root of the sum of the squares (SRSS) or the complete quadratic combination (CQC) of the design for Pi corresponding to the ith mode of the structural component.

SRSS approach:
751.9.1.3 SRSS.jpg





CQC approach:
751.9.1.3 CQC.jpg




where:
and

where n = the total number of modes of structure considered, Pi is calculated according to seismic design force Fi which is the design force corresponding to the structural ith mode with fundamental period of Ti and seismic response coefficient of Csi, Pi and Fi represent internal force of individual structural component and external seismic force applied to the structure respectively, Pj is similar to Pi , αij is the cross-correlation coefficient indicating the crosscorrelation between modes i and j, wi is the natural frequencies corresponding to the ith mode and ρ is the damping ratio (i.e. 0.05). For more detailed descriptions of procedures 1, 2, 3, and 4, see AASHTO Division I-A 4.3-4.6 and for a more detailed description of how to calculate Pi and Fi, see AASHTO Division I-A Commentary C.4.5.4.

For Seismic Performance Category (SPC) A, the above mentioned analysis procedure is not required.

For a regular bridge in SPC B, C, or D, procedure 1 and 2 are the minimum required analysis methods, procedure 3 is strongly recommended. A regular bridge, as described in AASHTO Division I-A, 4.2 has fewer than seven spans, no abrupt changes in weight, stiffness, or geometry and no large change in these parameters from span to span, or support to support (abutments excluded). Any bridge not satisfying the definition of a regular bridge is considered to be irregular. For an irregular bridge, procedure 3 must be used. The designer may use procedure 4 in place of procedure 3 if so desired.

Multi-mode spectral analysis is recommended for most bridges. Time History analysis is generally not recommended because its application requires considerable engineering judgement and experience.

Fig. 751.9.1.3.3 Seismic Map

751.9.1.4 Seismic Performance Category (SPC), Acceleration Coefficient (A)

Additional Information
AASHTO Div. I-A, 3.2-3.4, and foldout map (Figure 1.5) at back of Division I-A

Missouri is divided into four Seismic Performance Categories (SPC A, B, C and D, see Fig. 751.9.1.3.3, based on Acceleration Coefficients (A). The map for SPC and rock acceleration A is based on a 90% probability that the horizontal rock acceleration will not be exceeded in the 50-year lifetime of the bridge, corresponding to a return period of 475 years. For Missouri, the maximum A=0.36. For bridges with A > 0.29, an additional factor called Importance Classification (IC) is used to distinguish between SPC C and D.

751.9.1.5 Elastic and Plastic Design

Additional Information
AASHTO Div. I-A, 3.7

In some cases, bridges can resist seismic forces elastically, that is, without permanent deformations. In other cases, it is not economical to design a bridge for elastic behavior under seismic loading, so the bridge may be designed for inelastic (plastic) behavior. However, plastic design requires careful detailing to ensure ductility and connections with higher energy absorption characteristics. Plastic behavior is nonlinear, but AASHTO Division I-A allows an approximate analysis procedure using a linear elastic analysis along with the application of a response modification factor (R) to account for the assumed level of ductility and redundancy. This allows the use of linear elastic analysis programs such as SEISAB (or any other seismic analysis program). Response modification factors are specified in AASHTO 1-A, Article 3.7. An example of ductility demand is described below:

Additional Information
AASHTO Div. I-A, 1992 Commentary C3.6
In an elastic seismic analysis, a column in a multiple-column bent is subjected to an elastic moment, Me , and a rotation, θmax at the bottom of the column. The dashed line in Figure 751.9.1.5 represents the elastic moment demand. If plastic behavior is allowed and a maximum ductility factor, μ, equal to 5 is used, then . The column is then sized so that its plastic moment capacity, Mp, is greater than or equal to the modified elastic moment, MME, such that . This is based on the assumption that the deformations produced by a given seismic input force, F, are essentially the same for both elastic column behavior and for column yielding behavior at a ductility demand of μ = 5. Response modification factors (R) are allowed because of component ductility capacity and because of redundancy provided by adjacent columns, piers, and abutments.
Fig. 751.9.1.5 Moment Ductility Demand on a Column
rotation at bottom of column (elastic or plastic)

751.9.1.6 Structural Analysis Model

The bridge is usually modeled using idealized linear elements, connection nodes and lumped masses. The lumped masses are placed throughout the structure (see Fig. 751.9.1.6) to model the mass distribution (a mass matrix, [M]). Structural stiffness is approximated using linear springs for substructures (a stiffness matrix, [K]). A coefficient of damping is selected for the overall system (usually 5%, represented by a damping matrix, [C]). The displacements, velocities and accelerations of the system are represented by:

and

vectors in the structural dynamic analysis equation as shown below:

eq. 1

in which:

{Feq} is the seismic induced force vector

The development of multi-mode response spectrum analysis is based on the above dynamic equation.

Fig. 751.9.1.6 Lumped Mass Model of a General Bridge
where: m1m4 = Lumped Masses
m1 = M2 / 4
m2 = M2 / 4
m3 = M2 / 4
m4 = M2 / 8
where M2 = total mass of span 2

751.9.1.7 Directional Load Cases

The AASHTO Div. I-A specifications specify two major load cases to provide for combinations of longitudinal and transverse seismic forces:

Additional Information
AASHTO Div. I-A, 3.9
Case I = L + 0.3*T (This is loading case 3 in SEISAB.)
Case II = 0.3*L + T (This is loading case 4 in SEISAB.)

751.9.1.8 Group Loading

The group loading includes dead load (D), earth pressure (E) and seismic (EQ) loads, and other possible loadings such as buoyancy (B) and stream flow pressure (SF). Thus:

Additional Information
AASHTO Div. I-A, 6.2 and 7.2
Group Load = 1.0*(D+B+SF+E+EQ),

This is to be considered as a Load Factor group loading, but it may also be considered as a Service Load if the allowable overstresses in Division I-A are used. Wind and temperature loads are not included in this group and need not be applied simultaneously with seismic loads.

751.9.1.9 Seismic Performance Category Specifications

Additional Information
AASHTO Div. I-A, Sections 5, 6 and 7

Each Seismic Performance Category has its own seismic specifications. All categories require minimum support lengths at expansion gaps and adequate connections between superstructure and substructure. Categories B, C and D have additional specifications concerning foundations, abutments, special pile requirements, column design and footing design. See AASHTO Division I-A for details of specifications.

751.9.2 Seismic Analysis Model

751.9.2.1 Flowchart of Seismic Analysis Procedure

Fig. 751.9.2.1. "Section 6.1.2.7" is EPG 751.9.2.7 Rigid Body Transformation and "Section 6.12.10" is EPG 751.9.2.10 Iterative Abutment Analysis

751.9.2.2 Checklist for Seismic Computations

See Fig. 751.9.2.1.

0) GROUP I-VI DESIGN

____ The bridge should have already been designed for Group I-VI loads.
____ If expansion gaps are present, check seismic support lengths EPG 751.9.2.3.

1) SOIL PROPERTIES

____ Determine the soil properties at each bent as a function of depth at each bent EPG 751.9.2.4.
____ Check the factor of safety against liquefaction EPG 751.9.2.5, for all layers of soil that might liquefy, before determining all spring constants.

2) STIFFNESSES

____ Determine the stiffnesses at applicable piles, footings and abutments using the approved stiffness methods EPG 751.9.2.6.

3) RIGID BODY TRANSFORMATION (Stiffnesses)

____ Use RBT to compute the equivalent master joint stiffness matrix at abutments and pile footings EPG 751.9.2.7.

4) SEISMIC STRUCTURAL ANALYSIS PROGRAM

____ Prepare the input for the SEISAB, SAP2000 or any seismic analysis program, and run the program to perform a seismic analysis.

5) RIGID BODY TRANSFORMATION (Forces)

____ Use RBT and the master joint's force output from the Seismic Structural Analysis Program to compute the individual element forces at the original local slave joints EPG 751.9.2.7.

6) ITERATIVE ABUTMENT ANALYSIS

____ Check soil pressures and pile stresses against allowables as described in the iterative abutment analysis flowchart EPG 751.9.2.10. If necessary, either perform remedial actions or reduce the spring constants and iterate until pressures and stresses are within allowable limits.
____ When abutment element forces are OK, check resultant abutment displacement against the allowable. If the displacement is excessive, perform remedial actions and iterate until displacements are within allowable limits (EPG 751.9.2.10).

7) CONNECTION DESIGN EPG 751.9.3.1

____ Design any required connections such as anchor bolts, dowel bars, restrainers, stud plates, shear blocks, concrete end diaphragms, isolation systems, T-joints, etc. If structural behavior changes as a result of connection design, then revise and repeat any applicable steps listed above.

8) ABUTMENT COMPONENT DESIGN EPG 751.9.3.2

Wings (Integral & Non-Integral Abutments)

____ Design wings for shear and flexural reinforcement.

Non-Integral Abutments

____ Check stability using the Mononobe-Okabe active pressure.
____ Design the backwall thickness and flexural bars for shear and moment from active seismic pressure, restrainer forces and deadman anchor forces.
If abutment behavior changes as a result of abutment component design, then revise and repeat any applicable steps listed above.

9) INTERMEDIATE BENT DESIGN

____ Complete steps 0-6 before designing the intermediate bents. See EPG 751.9.3.3.1 and EPG 751.9.3.3.2 for definitions of terms below.

Column & Footing Intermediate Bents EPG 751.9.3.3.1

____ First, try to design the columns, footings and beam for the full elastic demand forces. If elastic design fails, then size the columns for modified elastic demand forces, and design footings and beam for the overstrength plastic capacity of that column size. Check T-joint stresses.

Pile Caps Intermediate Bents EPG 751.9.3.3.2

____ First, try to design the piles and beam for the full elastic demand forces. If elastic design fails, then design the pile for modified elastic demand forces, and design the beam for the overstrength plastic capacity of that pile size. Check T-joint stresses.

Drilled Shaft Intermediate Bents EPG 751.9.3.3.3

____ First, design the columns, shafts and beam for the full elastic demand forces. If elastic design fails, then size the columns for modified elastic demand forces, and design shafts and beam for the overstrength plastic capacity of that column size. Check T-joint stresses.

751.9.2.3 Minimum Support Length

Additional Information
AASHTO Div. I-A, 3.10 and AASHTO Div. I-A, 5.3, 6.3, 7.3

At expansion gaps (near abutments, intermediate bents and hinges), the substructure must accommodate differential seismic displacements between the substructure and the superstructure. The minimum support length capacity, N(c), of the substructure beam shall meet or exceed the minimum support length demand, N(d), of the superstructure girders.

N(c) > = N(d)

At fixed bents, minimum support length need not be calculated.

Fig. 751.9.2.3 Minimum Support Length

Seismic Performance Categories A & B

English Units
N(d) = [8 + 0.02*L + 0.08*H]*(1 + 0.000125 S2 ), (inches)
Metric Units
N(d) = [203 + 1.67*L + 6.66*H]*(1 + 0.000125 S2 ), (mm)

Seismic Performance Categories C & D

English Units
N(d) = [12 + 0.03*L + 0.12*H]*(1 + 0.000125 S2), (inches)
Metric Units
N(d) = [305 + 2.5*L + 10*H]*(1 + 0.000125 S2 ), (mm)
Additional Information
AASHTO Div. I-A, 3.10

Term Definitions for SPC A, B, C and D:

N(d) = minimum support length demand, in inches or mm
L = in feet or meters, as defined below
L = length of the bridge deck unit to the adjacent expansion joint or to the end of the bridge deck. For hinges within a span, L shall be the sum of , the distances to either side of the hinge. For single span bridges, L equals the length of the bridge deck. Units of L are feet or meters.
H = in feet or meters, as defined below:
H = (For abutments) The average height, from the c.g of the superstructure to the c.g. of the footing, for all bents supporting the bridge deck to the next expansion joint. H = 0 for single span bridges.
H = (For column intermediate bents) The height from the c.g. of the superstructure to the c.g. of the average footing at the expansion bent only.
H = (For pile cap & drilled shaft intermediate bents) The height from the c.g. of the superstructure to a point 5 times the pile diameter below the groundline, at the expansion bent only.
H = (For hinges within a span) The average height, from the c.g. of the superstructure to c.g. of the footing, for the two bents adjacent to the hinge.
S = Skew angle of the support, measured from a line normal to the span, in degrees.
N(c) = The shortest distance (in any direction) from the end of the girder and the edge of the substructure beam, in inches or mm, measure normal to the face of the substructure beam.

751.9.2.4 Material Properties

751.9.2.4.1 Soil Properties

Soil Profiles

From the boring data in the design layout file, determine the soil properties at known cores and borings. Cores describe soil types in each soil layer plus soil property test data at regular depth increments (usually 5 feet). Borings only describe soil types in each soil layer, without the test data. When soil properties are not well-documented at all bent locations, estimate soil properties based on the best available information. On a profile sheet, draw the cores and borings to scale at their appropriate stations and elevations. Match up soil types from borings to estimate properties from cores, or use linear interpolation between known cores.

Standard Penetration Test (SPT)

The most common test data reported in cores are Standard Penetration Test(SPT) blowcounts per foot (N). If only SPT data are known, other properties such as N, φ, c (same as S), γ, E, ν, and other soil properties can be estimated using correlation charts. Correlations with N blowcounts are fairly reliable for sands, but are less reliable for clays. The SPT blowcounts are given for three 6 in. intervals, and the first datum is thrown out in order to avoid seating errors. The soil shear strength, in KSF, can be estimated as S = N / 10. Hereafter, N represents (N1)60 which represents the standard penetration test blowcounts corrected to 60% of the theoretical free fall energy delivered by the hammer system used to the top of the drill stem and to a overburden stress of 1 ton/ft2.

Note: Common soil property correlations are maintained in the Bridge Division, Development Section, prepared by Construction and Materials Division, Geotechnical Section.

Example:
Given: SPT data = 6 / 9 / 8 in 6-in. increment layers
Compute: Soil Shear strength in KSF
The 6 blows for the first 6 in. are ignored.
N = (9 in 6") + (8 in 6") = (17 blows per 12") = 17 blows/foot.
S = N / 10 = 17 / 10 = 1.7 KSF = Soil Shear Strength

The standardized penetration resistance (N1)60 is based on standardized equipment and procedure (E. Kavazanjian, etc., 1997). Other “non-standard” equipment and procedural details can affect the measured penetration resistance, and require correction of the blow counts in order to develop the (N1)60. The details of corrections can be found in the reference by E. Kavazanjian, etc., 1997.

Form 751.9.2.4.1.1, Soil Parameter Request Form

MoDOT soils specialists perform the SPT tests and provide corrected penetration resistance (N1)60. (N1)60 is included in the standard soil parameters request form as shown in Form 751.9.2.4.1.1. This form shall be used to request soil parameters in the request for soundings.

Compacted Backfill at Abutments

Additional Information
Sec. 203.3.4 and Sec. 206.4.9

Backfill at abutments shall be compacted to 95% of maximum density, and it may consist of sands, clays, silts, gravels or a mixture. Call the district and ask what type of borrow soil will be used for compacted fill at abutments. Soil property correlations may be used for estimating Young's Modulus (E).

Ultimate Soil Pressure at Abutments For integral and non-integral end bents, use 7.7 KSF as the ultimate soil pressure. This is based on CalTrans' recommendations, usage by other state DOTs, and tests performed at the University of California at Davis.

751.9.2.4.2 Concrete Properties

The concrete compression strength, f’c, should be a probable, rather than a minimum. 1.5 f’c shall be used in the seismic analysis. This over the specified strength recognizes the typically conservative mix designs and the natural strength gain with concrete age.

The flexural rigidity of columns, beam cap and c.i.p. piles should be calculated based on the cracked sections, rather than gross member section. Natural periods should also be based on the cracked sections. The flexural rigidity of the cracked section is defined as the rigidity at which the first steel rebar reaches the yield limit state.

Figure 751.9.2.4.2 shows the moment of inertia ratio, Ie/Ig, for circular and rectangular columns.

Fig. 751.9.2.4.2, Adjustment Factors for Effective Stiffness for Concrete (Priestly et al, 1996)
In Fig. 751.9.2.4.2:
Ag = gross section area
Ast = steel section area
Ig = gross moment of inertia
Ie = effective moment of inertia of cracked section
f'c = compressive strength of unconfined concrete
P = applied axial compressive load

751.9.2.4.3 Steel Properties

Yield strength of reinforcement should be based on mill certificate or tensile test results if available. If not, a nominal strength of 1.1 times the specified minimum strength should be assumed, resulting in 66 ksi yield strength for grade 60 reinforcement. (Priestly et al,1996; FHWA, 1995)

751.9.2.5 Liquifaction

Conditions for Liquefaction

Additional Information
Volume II of report #FHWA/RD-86/102, sections 4.2-4.3

When subjected to seismic ground motions, some soils tend to liquefy - that is, to lose most of their shear strength. When ground shaking is intense and of long duration, soil pore pressures can build up and exceed the intergranular stress, causing loss of grain contact and loss of cohesion. Liquefaction of soil can lead to extremely large displacements and dramatic structural failure. Some high-risk factors for liquefaction might include:

Water Table Location = below water table, saturated, or water content greater than 0.9 * Liquid Limit,
Soil type = poorly-drained cohesionless soils or nonplastic silts with Liquid Limit < 35%,
Soil gradation = uniformly-graded and fine particle size, low percentage of plastic fines (< 5%),
Relative Density = loose, with relative density, DR < 50%,
Confining pressure = low confinement pressure, in top 50 ft. of soil,
Intensity of ground shaking = exceeding critical acceleration levels, close to epicenter,
Duration of shaking = long duration, numerous cycles.

When to Check Liquefaction

Additional Information
AASHTO Div. I-A, 1992 Commentary, C6.3.1(A), C6.4.1(A), C6.5.1(A)

The Soil Report should include the factor of safety against liquefaction, but if it is not the bridge designers should calculate the factor of safety against liquefaction for each saturated (submerged under the water table) soil layer at each bent. Do not check compacted abutment fill near vertical end drains. If the factor of safety against liquefaction is less than 1.3, then consider the possibility of liquefaction as explained in Step 3 below. If both the designer and checker agree that the factor of safety against liquefaction is less than 1.0, then consult the Structural Project Manager about the possibility of lengthening piles, increasing pile sizes, or soil strengthening measures.

Step 1:

Compute the seismically-induced (active) cyclic stress ratio, .

= average earthquake-induced shear stress on the sand layer under consideration, psf.
= initial effective overburden pressure, psf (Use γ' = γt - γw, below the watertable, where γw = 62.4 pcf).
A = Acceleration Coefficient
= total stress at mid-layer of soil, psf, = Σγt*Ht for each layer from the ground surface down to the layer being investigated.
rd = a stress reduction factor varying from 1.0 at ground surface to 0.9 at about 30 ft. deep, remaining at 0.9 for depths below 30 ft.

Step 2: Determine the (resistive) cyclic stress ratio, , as described below.

From Fig. 751.9.2.5.1, enter with (N1)60 and M, and determine the (resistive) cyclic stress ratio, . (N1)60 is described in EPG 751.9.2.4.

In the absence of getting a Richter magnitude, M, from the geotechnical engineer, the USGS deaggregation map can be used or the following table may also be used, where “A” represents the design acceleration coefficient.

A = 0.04g M = 4.25
A = 0.08g M = 4.75
A = 0.16g M = 5.75
A = 0.33g M = 7.00
A = 0.50g M = 8.50

The USGS deaggregation maps are available at http://eqint.cr.usgs.gov/deaggint/.

Step 3:

Calculate the factor of safety against liquefaction.

FS = ≥ 1.3 (desired) or 1.0 (required)

If FS ≥ 1.3, then analyze the bridge on the assumption that liquefaction will not occur. If FS < 1.3, then assume liquefaction might occur within the layer under consideration: this consists of running two seismic analyses to design the bridge for both possibilities of: a) liquefaction and b) no liquefaction. Note that superstructures may be subject to large lateral movement when soil liquefation is considered in the seismic analysis. Hence, expansion bearings shall be designed to tolerate these movements. For CIP concrete piles, determine the maximum pile moment and depth, with and without liquefaction, and design reinforcement down to the development length below that depth, as necessary.

Additional Information
AASHTO Div. I-A, 6.4.2(C), 7.4.2(C)

The residual strength of the liquefied soil layer may be considered. The calculation of residual strength is described below.

Residual Strength

Liquified soil has a residual shear strength, Sr, which can be considered for the pile stiffness computations. When not enough information is available, use a residual strength of zero. The residual shear strength shall not be more than the non-liquefied shear strength.

The residual shear strength of liquefied soil can be estimated by using the corrected penetration resistance, (N1)60, as described previously, but with an additional correction factor, Ncorr, for fines contents to generate an equivalent “clean sand” blowcount value (N1)60-CS = (N1)60 + Ncorr, where Ncorr are shown in Table 751.9.2.5.

Table 751.9.2.5 Corrections to Blowcounts for Percent Fines (Ncorr)
Percent Fines Ncorr (blows/ft)
10% 1
25% 2
50% 4
75% 5

Figure 751.9.2.5.2 presents an updated correlation between Sr and (N1)60-CS (FHWA-SA-97-076, 1997). For (N1)60-CS > 16 blows, continue the curve as a straight line at the same slope as at 16 blows.

Fig. 751.9.2.5.1, Resistive Cyclic Stress Ratio
(AASHTO Div. I-A 1998 Commentary, Fig. CA1).
Note: AASHTO's N1 is actually (N1)60
Fig. 751.9.2.5.2, Relationship Between Corrected Blowcounts (N1)60-CS (Blows/ft.) and Undrained Residual Strength, Sr (psf).
(FHWA-SA-97-076, 1997)

751.9.2.6 Spring Constants

751.9.2.6.1 Modeling Abutment Stiffnesses

"Full-Zero" Abutment Stiffnesses

For the "full-zero" stiffness approach, one abutment's backfill is in compression (full soil springs are engaged) while the other abutment's backfill is in tension (this backwall soil spring is zero because soil tensile strength is negligible. Note that although the backwall soil stiffness is zero, the pile, beam and wing stiffnesses are NOT zero.) To account for compression and tension at both abutments, two Seismic Structural Analysis programs are required:

(Program # 1) Use full springs at all pile and soil springs, except set the backwall spring equal to zero at the FIRST abutment only, and
(Program # 2) Use springs at all pile and soil springs, except set the backwall spring equal to zero at the SECOND abutment only.

For analyzing and designing the structure, use the worst case forces from these two models. When these "full-zero" models are used, the resulting longitudinal abutment soil force does not require adjustment as it would in the "half-half" model.

"Half-Half" Abutment Stiffnesses

For skewed bridges, the "half-half" method should not be used. For the "half-half" stiffness approach, half of the backwall soil stiffness is used at each abutment, in addition to the full stiffnesses at all other abutment spring elements (piles, beams, wings, etc.). After the seismic analysis, the "halfhalf" method also requires doubling the backwall force.

Non-Integral Abutments

For non-integral abutments with restrainers, three separate Seismic Structural Analysis Programs are required:

(1) With restrainer elements only on the first abutment: This model covers movement toward the last abutment.
(2) With restrainer elements only on the last abutment: This model covers movement toward the first abutment.
(3) Without restrainer elements: With no restrainers, the components of the springs that are longitudinal with respect to the bridge centerline will have no effect.

Point-of-Fixity Approximations for Piles

Avoid using the point-of-fixity formulas (U.S. Steel Design Handbook, 1965 & NHI Course No. 13063, 1996). Stiffnesses based on estimated points of fixity are not recommended, for several reasons:

a) For standard integral pile cap END bents, there is DOUBLE-curvature bending in both directions. The point-of-fixity formulas were apparently derived for SINGLE-curvature bending, so the formulas should not be used for most standard integral end bents.

b) For standard INTERMEDIATE bents, out-of-plane bending is usually single-curvature, and in-plane bending is usually double-curvature, and one fixity length cannot model the different bending cases in both directions at the same time. Therefore, the point-of-fixity formulas should not be used for most standard intermediate bents.

c) The point-of-fixity formulas also assume homogeneous soil (no layers). When piles or drilled shafts penetrate through multiple varying soil layers, or when the water table is near the top of the pile head, use programs such as SPILE and COM624P because of their more accurate analyses and their more detailed soil layer geometries.

d) It is virtually impossible to select a point of fixity such that both the maximum deflection and maximum bending both were computed correctly.

751.9.2.6.2 Abutment Stiffness, Wilson Equations

Abutment Soil Types

Compacted Backfill: Wings, Backwall and possibly Beam
Additional Information
Sec. 203.3.4 and Sec. 206.4.9
Call the district to determine the type of borrow soil that will most likely be used as abutment backfill. When estimating soil properties (see EPG 751.9.2.4), consider that backfill is compacted to 95% maximum density, so assume dense or stiff conditions.
Natural (in-situ): possibly Beam
Use available boring data for estimating soil deposit properties.

Abutment Spring Types

Spring Location Direction of Spring Type of Soil at Location
____ Backwall Horizontal, normal to backwall Compacted backfill
____ Beam Vertically downward In-situ? or compacted?
____ Wings Horizontal, normal to wing Compacted backfill
Fig. 751.9.2.6.2 Abutment Springs
Orientations of Wilson Equation Stiffnesses

Wilson Equations (Wilson, 1988) For translational and rotational stiffnesses on plate-like elements such as backwalls, wings and beams, use the Wilson equations:

Translation normal to the plane
, kip/ft.
Rotation about the transverse axis (y-axis)
, kip * ft/radian.
Rotation about the longitudinal axis (x-axis)
, kip * ft/radian.
The axis orientation for each element used to determine Kθx and Kθy is shown in Fig. 751.9.2.6.2 Element Orientation, below. If K is reduced as in EPG 751.9.2.10 Iterative Abutment Analysis, then Kθ must also be reduced.
K = estimated equivalent linear stiffness for translation, kip/ft.
Kθ = estimated equivalent linear stiffness for rotation, kip*ft/radian
E = Young's Modulus of soil at spring location, either for in-situ soil or for compacted backfill, ksf
L = length of item, ft.
For backwall, L = length of backwall along skew, to inside wing face
For wings, L = inside layout length of wing
For beams, L = skewed length of beam along cl. beam
= Poisson's Ratio of soil at spring location, either natural or compacted
= Shape factor for soil contact area
B = height or width of item, ft.
For backwall, B = height from top of slab to bottom of beam
For wings, B = equivalent height of wing = (wing area)/(wing L) For beams, B = beam width normal to beam
Fig. 751.9.2.6.2 Element Orientation

751.9.2.6.3 Pile Axial Stiffness

General Procedure

1) From the boring data and the bridge profile plot, determine the SPT blowcounts along the pile length.

2) Determine the soil properties required for the SPILE computer program or any other computer programs based on the methods presented by Nordlund (1963,1979), Thompson (1964), Meyerhoff (1976), Cheney and Chassie (1982), and Tomlison (1979,1985). Assume that the groundwater table is at the Normal Water Surface Elevation.

3) Run the SPILE program (Urzua,1993) or other programs using the methods described above to determine Qb and Qf.

4) Determine the axial pile stiffness, K, as described below for friction piles and bearing piles (Lam and Martin, 1986).

Friction Piles

Qu = the ultimate axial pile capacity, in kips (or tons)

Qf = the ultimate friction capacity from SPILE, in kips (or tons)

Qb = the ultimate bearing capacity from SPILE, in kips (or tons)

For steel HP friction piles, use the box perimeter for friction, but use the HP steel area for bearing.

In compression, Qu= Qf + Qb
In tension, Qu = Qf because Qb = zero.

The typical pile resistance – displacement relationship is shown in Figure 751.9.2.6.3.

At a displacement, z, at which the pile capacity is less than the ultimate capacity (q < Qu ), the partial capacity, q, is equal to the sum of the partial friction capacity, f, and the partial bearing capacity, b.

q = f + b, in kips

f = friction mobilized along a pile segment at a displacement, z ≤ zc

, kips

zc = the critical displacement of the pile segment at which Qf is fully mobilized. Use zc = 0.2 in.

b = tip resistance mobilized at a displacement, z ≤ z'c

, kips

z'c = the critical pile displacement at which Qb is fully mobilized.

Use z'c = 0.05*D, inches

D = least pile dimension (D = diameter for C.I.P. piles), inches

However, the pile itself will deform, also. This pile deformation or pile compliance, δ, should be included in the pile resistance – displacement curve as shown in Fig. 751.9.2.6.3.

pile compliance = pile deformation, inches

q = f + b = compressive axial load corresponding to a pile displacement z, kips

L = total friction length of the pile in the soil, inches

AE = For concrete C.I.P. piles, AE = AcEc+AsEs, kips.

For steel HP piles, AE = AsEs, kips.

From Figure 751.9.2.6.3, it can be seen that the pile axial load-axial deformation curve is nonlinear. If response spectrum method is considered in the analysis, the secant modulus stiffness is used. The secant modulus stiffness, Ks, is defined as the slope between two points at which the axial loads are equal to zero and Qu/2. For regular highway bridge foundation piles, typical levels of cyclic compression loading would be from 50 to 70% of Qu.

Fig. 751.9.2.6.3 Pile Axial Stiffness Model

Steel HP Bearing Piles

In compression, Qf = 0, because bearing piles bear directly on rock.

In tension, Qf = the ultimate friction capacity of the pile.

Qb = the ultimate bearing capacity, in kips (or tons)

Qb = 0.25 * fy * As (AASHTO 4.5.7.3), where:
As = the HP steel pile area, in square inches
fy = yield stress of the pile steel, in ksi

In compression, Qu = Qb, because Qf = zero.

In tension, Qu = Qf, because Qb = zero.

The pile is more often in compression due to preloading from dead load, so the pile axial spring constant can be calculated as:

where:

AE = AsEs, kips, using the HP steel area, square inches.

L = total length of pile between the pile cap and the point of bearing on rock, inches.

Pile Group Effects

Design pile footings with a center to center spacing of more than or equal to 3 pile diameters.

a) Pile group capacity in cohesionless soils: The ultimate group capacity for driven piles in cohesionless soils can be taken as the sum of the individual ultimate pile capacities.

b) Pile group capacity in cohesive soils:

1) For pile groups driven in clays with c ≤ 14 psi, a group efficiency of 0.7 (i.e. use 70% of the sum of the individual ultimate pile capacities) for center to center pile spacings of three times the pile diameter. If the center to center pile spacing is greater than 6 times the pile diameter, a group efficiency of 1.0 may be used. Linear interpolations should be used for intermediate center to center pile spacings.
2) For pile groups driven in clays with c > 14 psi, a group efficiency of 1.0 may be used.

751.9.2.6.4 Pile Lateral and Rotational Stiffness, (p-y curves)

Calculating Stiffnesses

The pile lateral translational spring constants are determined using estimated soil properties and the COM624P computer program (Wang and Reese, 1993) or any other programs that utilize non-linear p-y curves for either single piles or a pile group.

1) First, set up the soil depth profile at the pile location. Use the boring data and the bridge profile plot to determine the SPT blowcounts along the pile length.

2) For a given soil profile, the pile lateral force-lateral deflection curve at the top of pile (pile head) can be obtained by applying incremental lateral forces at the pile head, the program then calculates the corresponding lateral deflections at the pile head. The material non-linearity of the pile is also considered in the program. Similarly, pile moment-rotational curve at the top of pile can be obtained by the COM624P program.

Since the response spectrum method is based on linear analysis, the secant modulus stiffness is used to represent the equivalent linear stiffness. The secant modulus stiffness is defined as the slope between two points at which the lateral loads are equal to zero and P(Mu)/2, where Mu is the ultimate moment capacity of the pile; P(Mu) represents the lateral load at which Mu is developed in the pile. The ultimate moment capacity of CIP pile or composite concrete-steel shell pile is based on the limit state of concrete strain, εc=0.003 and the steel shell strain, εs=0.015. The ultimate moment capacity of steel HP pile is equal to the plastic moment, Mp, of the pile under constant axial load due to superstructure and substructure loads.

3) It should be recognized that using the secant stiffness approach (including axial, lateral, and rotational stiffness) in the seismic analysis is an approximation method to simplify the time consuming non-linear dynamic analysis following the load-deformation relationship of the pile head. In general, using the secant stiffness approach in conjunction with the pile stress check described in EPG 751.9.2.10 Iterative Abutment Analysis gives reasonable solutions in the design process without conducting an iterative procedure.

Example 6.1.2.6.4. Find the stiffness of an individual pile at the groundline level which represents the characteristics of the soil–pile interactions.

Description: A pile-cap bent with four steel HP12 x 53 piles is shown in Fig. 751.9.2.6.4.1. The bent has skew of 54.5 degrees. For individual piles, the stiffnesses of pile-soil interaction are estimated using COM624P computer program, then these stiffnesses are used to form Point elements in the structural model as shown in Fig. 751.9.2.6.4.2. The point elements are located at the ground level which represent the characteristics of the pile-soil interactions.

Fig. 751.9.2.6.4.1 Intermediate Pile Bent
Additional Information
Fig. 751.9.2.6.4.3 Test 5.out
Fig. 751.9.2.6.4.4 Test 6.out
Fig. 751.9.2.6.4.4 Test 6.out, second page
Fig. 751.9.2.6.4.5 Test 5B.out
Fig. 751.9.2.6.4.6 Test 6B.out
Fig. 751.9.2.6.4.6 Test 6B.out, second page

The soil is classified as stiff clay with c = 2 ksf; γ= 0.069 pci; ε50= 0.007; and k =400 pci, where c is the undrained shear strength of clay; γ is effective unit weight; ε50 is the strain corresponding to one-half the maximum principle stress difference; and k is the variation of soil modulus.

In order to formulate the stiffnesses of pile-soil interaction, the computer program COM624P is used to obtain the translational, rotational and rotational-translational coupling stiffnesses for joints 9, 10, 11, and 12 (see Fig. 751.9.6.1.2.6.4.2). The COM624P output for fixed head and applied lateral forces in the ye direction, hinge head and applied moment in the ze direction, fixed head and applied lateral forces in the ze direction, and hinge head and applied moments in the ye direction are shown in the output files TEST5.OUT, TEST6.OUT, TEST5B.OUT, and TEST6B.OUT, respectively.

Fig. 751.9.2.6.4.2 Structural Model

From the TEST5.out and TEST6.out outputs, the stiffnesses of point element S33 (or S(3,3)), S35 (or S(3,5)), S55, S22, S26, and S66 can be calculated as follows:

a) For S33:

Plastic moment Mpye = 1159.2 k-in.

579.6 k-in, which is close to M=548 k-in in the SUMMARY TABLE of TEST5B.OUT

142.9 k/in.

b) For S35:

3914 (kip/rad)in which δ is the lateral displacement at pile head.

c) For S55:

Since 579.6 k-in is close to 600 k-in, S55 can be obtained from TEST6B.OUT as

751.9.2.6.4 579.6 k in.jpg

Total rotation at top of the pile is θye= 0.0123/5 = 0.0025 rad.

240000(k-in/rad.)

6480(kip/rad.)

Since the program performs structural analysis using symmetric stiffness matrix, use average number for S35 and S53 approximately: S35 = S53 = (3914+6480)/2 = 5200 (kip/rad.)

d) For S22:

Plastic moment Mpze= 2664 kip-in.

M = (Mpze)/2 = 1332 kip-in. (From TEST5.OUT SUMMARY TABLE, it is between 1100 k-in. and 1630 k-in.)

159.2 (kip/in.)

e) For S26</sub:>

-6166 (kip/rad.)

f) For S66:

Since 1332 k-in. is closer to 1400 k-in., the S66 can be obtained from TEST6.OUT as

751.9.2.6.4 1332 k in.jpg

Total rotation at top of the pile θze = 0.0132/5 = 0.0026 rad.

538460 k-in./rad.

-10460 kip/rad.

Since the program performs structural analysis using symmetric stiffness matrix, use average number for S62 and S26 approximately: S26 = S62 = (−6166 − 10460)/2 = -8313 (kip/rad.)

g) For axial stiffness S11: 1498.33 kip/in

h) For torsional stiffness S44: GJ/L = (11100 x 1.12)/(25 x 12) = 41.44 kip-in/rad. Usually, the torsional effect of an individual pile is insignificant for the multiple-column bent.

Therefore, the stiffness matrix of the pile at the groundline level corresponding to the pile element coordinate system (xe, ye, ze) is:

751.9.2.6.4 xyz.jpg

Pile Group Effects:

Design pile footings with a center to center spacing of more than or equal to 3 pile diameters.

For center to center pile spacing of 3 pile diameters, it is suggested that a p multiplier, Pm, value of 0.8 be used to modify the p-y curve of individual piles along the lead row, 0.4 for the second row, and 0.3 for the third and subsequent rows. For larger center to center spacings, these Pm values should be conservative. Alternatively, using a Pm = 0.5 for all piles to represent the average adjustment factor is adequate in practical design for earthquake loadings. For center to center pile spacings of 6 pile diameters, the pile group effect can be neglected. For pile spacings between 3 and 6 pile diameters, us a linear interpolation between p multipliers of 0.5 and 1.0.

p-y Curves for Liquefied Soil:

The p-multiplier of 0.1 can be used for liquefied soil (MCEER Report 98-0018, 1998). If p-multipliers are not used, the residual shear strength of the liquefied soil can be used in accordance with EPG 751.9.2.5 where the soil type is determined from the residual shear strength soil property correlations that can be used for the p-y analysis.

751.9.2.6.5 Pile Lateral and Rotational Stiffness - Linear Subgrade Modulus Method

The lateral load-deflection characteristics of the pile-soil system are mildly nonlinear. The elastic pile usually dominates the nonlinear soil stiffness. Furthermore, the significant soil-pile interaction zone is usually confined to a depth at the upper 5 to 10 pile diameters. Therefore, simplified single-layer pile-head stiffness design charts are appropriate for lateral loading. The stiffness charts shown in figures 6.1.2.6.5-1 – 6.1.2.6.5-4 make use of a discrete Winkler spring soil model in which stiffness increases linearly with depth from zero at grade level where the location of the pile head is assumed. This linear subgrade stiffness model has been found to reasonably fit pile load test data for both sand and clay soil conditions. The coefficient f in these figures is used to define the subgrade modulus Es at depth z, representing the soil stiffness per unit pile length. Figs. 751.9.2.6.5.5 and 751.9.2.6.5.6 show f values for piles embedded in sand and clay respectively (assuming elastic pile). For the purpose of selecting an appropriate f value, the soil condition at the upper 5 pile diameters should be used.

These stiffness charts are appropriate for piles with embedded length greater than 3 times the pile characteristic length, λ. The following equation can be used to obtain the characteristic length of pile-soil system:

(1)

Embedment Effect

Soil resistance on the pile increases and the stiffness coefficients at the pile head increase with the depth of embedment due to additional overburden. Figs. 751.9.2.6.5.7 – 751.9.2.6.5.9 present pile head stiffness coeficients for pile embedment depths of 5 and ten ft. based on a subgrade modulus, which increases linearly with depth.

Pile Response and Load Distribution

The pile lateral and moment distribution can be estimated by the equations shown in the Figs. 751.9.2.6.5.10 and 751.9.2.6.5.11 for non-embedded and embedded piles respectively. In the figures, the A and B shape functions are non-dimensional and can be used to solve for the pile deflections and moments along the pile including the fixed pile head condition. Tables 751.9.6.5.1 – 751.9.2.6.5.7 give the data of the shape functions.

Example 1:

Find the stiffness matrix of a vertical pile shown in Fig. 751.9.2.6.4.1 at the groundline level.

Solution"
751.9.2.6.5 yz.jpg

1) Calculate S33:

EPG 751.9.2.6.5 Figures
Fig. 751.9.2.6.5.1
Fig. 751.9.2.6.5.2
Fig. 751.9.2.6.5.3
Fig. 751.9.2.6.5.4
Fig. 751.9.2.6.5.5
Fig. 751.9.2.6.5.6
Fig. 751.9.2.6.5.7
Fig. 751.9.2.6.5.8
Fig. 751.9.2.6.5.9
Fig. 751.9.2.6.5.10
Fig. 751.9.2.6.5.11

EIy = 29000 ksi x 127 in4 = 3.6 x 109 # - in4

From Fig. 751.9.2.6.5.6: for clay with undrained shear strength of 2 ksf, f = 32 pci

From Fig. 751.9.2.6.5.1, using EI = 3.6 x 109 # - in2 and f = 32 pci,

S33 = 5.5 x 104 lb/in

2) Calculate S55: From Fig. 751.9.2.6.5.2, using the same EI and f as in 1), S55 = 1.2 x 108 lb-in/rad. = 120000 k-in/rad.

3) Calculated S35: From Fig. 751.9.2.6.5.3, using the same EI and f as 1), S35 = 2.2 x 106 lb/rad. = 2200 k/rad.

4) Calculate S22: EIz = 11397000 k-in2 = 1.1 x 1010 #-in2

From Fig. 751.9.2.6.5.11, using new EI and the same f as above: S22 = 8.5 x 104 lb/in

5) Calculate S66: From Fig. 751.9.2.6.5.2, using the same EI and f from 4): S66 = 2.7 x 108 lb-in/rad. = 270000 k-in/rad.

6) Calculate S26: From Fig. 751.9.2.6.5.3, using the same EI and f from 4): S26 = 4 x 106 lb/rad. = 4000 k/rad.

7) S11 and S44 are the same as calculated in Example 1 in EPG 751.9.2.6.4. The completed stiffness matrix is as follows:

751.9.2.6.5 matrix.jpg

In comparison with the stiffness matrix calculated in Example 1 from EPG 751.9.2.6.4, there are some discrepancies between the two matrices. The reason for the discrepancies is because the linear subgrade modulus method (Lam, et al, 1991) is originally derived using a 1 inch deflection of the pile head in clay as shown on the figure below.

751.9.2.6.5 deflection.jpg

From the above figure, it is recommended using the secant stiffness approach for the pile stiffness estimation as described in EPG 751.9.2.6.4. If a p-y curve based computer program is not available, the linear subgrade modulus method may be used to estimate pile stiffness and moment distribution along a pile. However, using the linear subgrade modulus method may result in a significant underestimation of pile stiffness when a dynamic structural analysis shows that pile deflection is much less than 1 inch.

EPG 751.9.2.6.5 Tables
Table 751.9.2.6.5.1
Table 751.9.2.6.5.2
Table 751.9.2.6.5.3
Table 751.9.2.6.5.4
Table 751.9.2.6.5.5
Table 751.9.2.6.5.6
Table 751.9.2.6.5.7

Note: For the following example, λ = T from Fig. 751.9.2.6.5.10 & 751.9.2.6.5.11 and Tables 751.9.2.6.5.1 through 751.9.2.6.5.7.

Example 2:

Find: a) the lateral stiffness of the embedded pile-head, S33 shown below.

751.9.2.6.5 embedded pilehead.jpg
b) the moment distribution and lateral deflection along the pile using the linear subgrade modulus method.
pile-head is fixed
c = 2 ksf
γ = 0.069 pci
ε50 = 0.007
k = 400 pci
EIy = 3.6 x 109 #-in = 3.6 x 106 k-in2

Solve: a) Using Fig. 751.9.2.6.5.6 with c = 2 ksf, f = 32 pci

Using Fig. 751.9.2.6.5.7 with EIy = 3.6 x 109 #-in2 and f = 32 pci,
S33 ≈ 1.05 x 105 #/in = 105 k/in

b) From eq (1), the characteristic length:

= 40.76 in
Eso= f x 4ft = (32 pci) (4 x 12) = 1536 psi
1.178, use Table 751.9.2.6.5.5 (Eso ≈ 1.0)

from Fig.751.9.2.6.5.11:

Slope, S = (a)
Deflection, y = (b)


Moment, M = (Ptλ)Am + MtBm (c)

For a fixed-head pile: S=0

Substituting S=0 into eq (a),

S = 0 =, Where As and Bs are coefficients at the pilehead

= λAs + (Mt / Pt)Bs
∴(Mt / Pt) = -λ(As / Bs) (d) Where λ= = 40.76in.

From Table 751.9.2.6.5.5: As = -0.879 and Bs = -1.290 ∴ (As / Bs) = 0.681

Substituting eq (d) into eq (c),

Moment M = (Ptλ)Am +MtBm
=
=
= (10 kips x 40.76 in)(Am - 0.681Bm)
= 407.6 (Am - 0.681Bm) kip-in (e)

Using Table 751.9.2.6.5.5,the following table is created:

751.9.2.6.5 moment.jpg

Substituting eq (d) into eq (b)

y =
=
=
=
= 0.188(Ay - 0.681By) (f)

Using Table 751.9.2.6.5.5, the following table is created:

Z/λ Depth (z), in. Coefficients Deflection From eq (f)
Ay By
0.0 0.00 1.097 0.879 0.0937 in
0.2 8.15 0.923 0.641 0.0915 in
0.4 16.30 0.755 0.442 0.0854 in
0.8 32.60 0.460 0.153 0.0669 in
1.2 48.91 0.236 -0.012 0.0459 in
1.6 65.22 0.087 -0.087 0.0275 in
2.0 81.52 0.001 -0.104 0.0135 in
3.0 122.3 -0.044 -0.051 -0.0017 in
3.5 142.7 -0.031 -0.023 -0.0029 in
4.0 163.0 -0.016 -0.006 -0.0022 in
5.0 203.8 0.000 0.004 -0.0005 in

Check the pile stiffness: S33 = 10kips/0.0937in. = 107 k/in. which is very close to the value calculated in a) using Fig. 751.9.2.6.5.7.

751.9.2.6.6 Drilled Shaft Lateral and Rotational Stiffnesses

The diameter of the drilled shaft is usually much bigger than the typical piles used by MoDOT and the aspect ratio (length to diameter) is usually smaller for drilled shafts. Due to a smaller aspect ratio, the magnitude of rotation of the shaft can be more significant than for a pile. Therefore, the rotational resistance along the length and at the tip of the shaft, which is neglected for a typical pile, could be very significant. For simplicity, the procedure of using p-y curves for piles is recommended for drilled shafts. However, a scaling factor (larger than unity) shall be applied to either the linear subgrade modulus, Es, or the resistance value (p) of the p-y curves for shaft diameters greater than 24 inches. The scaling factor is the ratio of the shaft diameter to a 24 in. diameter shaft (Lam 1998).

Additional Information
Volume II of report #FHWA/RD-86/102, sections 5.0-5.8

751.9.2.6.7 Spread Footing Stiffness, Equivalent Circular Footing Method

For spread footings and caps of pile footings, the general form of stiffness matrix is summarized in the figure below, (Lam and Martin, 1986).

Spread Footing Foundation Matrix, [K0]

For spread footings, this is the master joint stiffness matrix located at the center of gravity of the footing. For pile footings, this stiffness matrix should be combined with the pile stiffness matrices using rigid body transformation. In general, the off-diagonal (cross-coupling) terms can be neglected, for two reasons: 1) the values of the off-diagonal terms are small, especially for shallow footings, and 2) they are difficult to compute. However, for some unusual deeply-embedded footings where the ratio of embedment depth to equivalent diameter is greater than five, the contribution of stiffness from the cross-coupling terms may need to be included.

Stiffness Matrix

The stifness matrix [K], of an embedded footing can be express as:

[K] = α ∗ β ∗ [K0] where:
[K0] = the stiffness matrix of an equivalent circular surface footing from the above figure.
α = the foundation shape correction factor using L/B from Fig. 751.9.2.6 Shape Factor and:
2L = the longer of the footing length or width in feet.
2B = the shorter of the footing length or width in feet.
β = the foundation embedment factor using D/R from Fig. 751.9.2.6 Embedment Factor and:
D = footing thickness in feet
R = equivalent footing radius as defined in the figure below, in feet. Note that R is different for different modes of displacement.
Equivalent Radius of Rectangular Footings

Equivalent Radius

Translational: (Translation about any axis)
Rotational: (Rocking about the 1-axis)
(Rocking about the 3-axis)
Torsional: (Torsion about the 2-axis)

Stiffness Coefficients

Horizontal translation (KF1F1) =
Vertical translation (KF2F2) =
Horizontal translation (KF3F3) =
Rocking rotation (KM1M1) =
Torsional rotation (KM2M2) =
Rocking rotation (KM1M1) =
Where:
G = Shear modulus for the soil directly beneath the footing, ksf
= , where E and ν are from EPG 751.9.2.4
ν = Poisson’s Ratio for the soil directly beneath the footing

Three idealized embedment conditions are represented in the figure below. To consider all of the cases of embedment effects, β would normally be a function of R, D and h. However, report # FHWA/RD-86/102 (Volume II) shows that the effects of ground cover and excavations can be ignored, and the situation depicted in Case 1 can be used to approximate the conditions in Case 2 and 3. Therefore, β can be determined based solely on D/R from Fig. 751.9.2.6.7 Embedment Factor for all three of the above cases.

751.9.2.6.7 embedment cases.jpg
Fig. 751.9.2.6.7 Shape Factor, α (Lam and Martin 1986)
Fig. 751.9.2.6.7 Embedment Factor, β

751.9.2.7 Rigid Body Transformation

An abutment consists of many translational and rotational springs which represent the interaction between soil and backwall, beam, wings, pile caps and piles as shown in Fig. 751.9.2.7A. To reduce the total number of degrees-of-freedom in the analysis and to take into account the geometric relationships among the spring constants, it is attractive to lump all the stiffnesses of these springs from “slave” joints to a “master” joint through a rigid body transformation. Any two joints on the rigid body (e.g. abutment) are constrained such that the deformation of one joint (the slave joint) can be represented by the deformation of the other joint (the master joint). Thus the degrees-of-freedom for the slave joint are transferred to the master joint, and the number of degrees-of-freedom in an abutment is reduced. Fig. 751.9.2.7B depicts the typical joints “j” and “m” for slave and master joints, respectively. For integral abutments, usually the center of gravity of the superstructure is chosen as the “master” joint as shown in Fig. 751.9.2.7A. RBT can also be applied to the pile footing by transforming all the pile springs and pile cap springs to an assigned master joint. Usually the master joint is placed at the center of gravity of the pile cap. The RBT takes into account the coupling effects between translational and rotational responses of skewed abutments.

Fig. 751.9.2.7A Abutment Spring Constants Considered

1) RBT for Stiffness

Before a seismic structural analysis computer program is run, RBT is used to sum up the stiffness effects of many individual springs (at different "slave joint" locations and in different local element directions) into one equivalent 6 X 6 stiffness matrix (at the "master joint" and in its joint coordinate system).

2) RBT for Force

After the seismic structural analysis program has been run, RBT uses the master joint's forces to back-solve for individual forces and displacements at the slave joints. Usually, the master joint's displacements are not used because the displacements are very small and are more difficult to backcalculate.

Fig. 751.9.2.7B Master Joint and Slave Joint Relationship

Iteration of RBT for Stiffness and Force

A) Abutments
Sometimes during Iterative Abutment Analysis (see Section 6.1.2.10), it becomes necessary to reduce spring constants at slave joints. If individual stiffnesses are reduced, then (1) and (2) above must be repeated to recompute the master joint stiffness matrix and to recompute the local slave element forces for each new iteration.
B) Pile Footings
If pile footing design significantly changes the assumed size and pile geometry of a pile footing, then (1) and (2) above must be repeated to recompute the master joint stiffness matrix and to recompute the local slave element forces for each new iteration. The distribution of seismic forces to bents is by stiffness, relative to each other, so a change in stiffness at one bent affects the force distribution to all bents, particularly the distribution between intermediate bents.
In order to perform rigid body transformation, several procedures are needed and defined in the remaining portion of EPG 751.9.2.7.

751.9.2.7.1 Joint Definition and Degrees of Freedom

A joint is defined as the point where one or more springs are connected. The assemblage of all springs becomes a structural model. The structural model is built by first defining the location and orientation of each joint.

1.) Global Coordinate System. The global coordinate system (GCS) defines the location of a structure. The GCS is a cartesian coordinate system, with three perpendicular axes xg, yg and zg. The zg axis is defined as xg cross yg (right hand rule), as shown in the figure below. The location of the GCS’s origin is arbitrary, and usually taken at the base of the structure.

2.) Joint Coordinate System. The location of a joint is defined by its xg, yg and zg coordinates in the GCS. Each joint is assumed to have six degrees of freedom (dof). The first three dof are translational, and correspond to the joint’s xj, yj and zj axes. The remaining three dof are rotational, about the joint’s xj, yj and zj axes as shown in the figure below. The xj, yj and zj axes define a joint coordinate system (JCS) for a given joint. The JCS may not be parallel to the GCS, and the JCS may vary for different joints. Thus, the orientation of the JCS for a given joint is defined by two vectors and . The origin of the JCS is at the joint. A third vector is then . The three vectors are written in matrix form as:

751.9.2.7.1 joint definition.jpg

where and are unit vectors parallel to the xg, yg and zg axes. Note that the orientation of the JCS determines the orientation of the global degrees of freedom.

Global (GCS) and Joint (JCS) Coordination System

751.9.2.7.2 Rigid Body Constraints

As shown in Fig. 751.9.2.7.2, summing the forces acting on the slave joint “j” about the master joint “m” in three dimensions, yields the force transformation matrix for a 3D rigid body as follows:

751.9.2.7.2.jpg

where {δm}j represents the displacement vector of the master joint, and {δs}j represents the displacement vector of the slave joint.

751.9.2.7.3 Spring Element Coordinate System (ECS)

Each structural component of an abutment or pile footing such as piles, pile caps, backwalls or wings contain several spring constants in the element coordinate directions. The direction of the individual ECS is defined by the designer. Fig. 751.9.2.7.3 shows some typical ECS for piles, pile caps, backwalls and wings.

Fig. 751.9.2.7.3 Spring Element Coordinate System

For example, in Fig. 751.9.2.7.3 (b), there are three translational springs, K11, K22, K33, in the ECS’ xe, ye and ze directions, respectively, and 3 rotational springs, K44, K55, K66, in the ECS’ xe, ye and ze directions, respectively.

751.9.2.7.4 Transferring Element Force Matrices

Transferring Spring Element Force Matrix From ECS to GCS

Let the element coordinate system be denoted xe, ye and ze at a joint. The three vectors that define the orientation of the ECS can be written in matrix form as:

751.9.2.7.4 ECS to GCS.jpg


Transferring Element Force Matrix From GCS to JCS

751.9.2.7.4 GCS to JCS.jpg

751.9.2.7.5 Transferring the Element Stiffness Matrix at Slave Joint “i” in its ECS to Master Joint in the JCS Direction

751.9.2.7.5-1.jpg
Example:
Transfer the pile-head stiffness matrix of pile no.2 as shown in Fig. 751.9.2.7.5 to the master joint at joint 17. In the figure, the pile footing consists of 16 piles and a rigid pile cap. The GCS (x, y, z) and ECS (xe, ye, ze) of the individual piles are also shown in the figure. Let all the joints JCS be in the same direction as the GCS and assume all the slave joints (at pilehead locations) have the same elevations as that of the master joint. The individual pile-head matrix corresponding to the pile ECS is:
751.9.2.7.5-2.jpg
It is assumed that the rotation and lateral movements at the pile-heads are small. Therefore, the rotational stiffnesses at the pile-head are neglected in this example.
Fig. 751.9.2.7.5 Pile Footing
751.9.2.7.5-3.jpg
751.9.2.7.5-4.jpg
751.9.2.7.5-5.jpg

751.9.2.8 Modeling of Intermediate Pile Cap and Drilled Shaft Bents

751.9.2.8.1 Coupled Foundation Stiffness Method - a Rigorous Method

A rigorous procedure to develop a linear 6x6 pile stiffness matrix at groundline has been described in the example in EPG 751.9.2.6.4. Fig. 751.9.2.8.1 illustrates the structural model used by this approach.

Fig. 751.9.2.8.1 Structural Model for Pile Cap and Drilled Shaft Intermediate Bents

The common form of the stiffness matrix in the local pile coordinate system (xe, ye, ze) is given in eq. (1) in which the diagonal terms Kx, Ky, Kz, Kθx, Kθy, Kθz are stiffnesses corresponding to translational and rotational degrees of freedom associated with xe, ye and ze axes, respectively. The off-diagonal terms represent coupling between two degrees of freedom. These stiffness coefficients can be calculated from the solutions presented in EPG 751.9.2.6.

751.9.2.8.1 k pile.jpg

751.9.2.8.2 Equivalent Cantilever Column Method - a Simplied Approach

In the equivalent cantilever method, the foundation is replaced by a cantilever column that has stiffness approximately equivalent to those of the pile and surrounding soil. This is represented in Fig. 751.9.2.8.2.

Fig. 751.9.2.8.2 Structural Model for Pile Cap and Drilled Shaft Intermediate Bents

This simplified approach may be used if a seismic analysis computer program is not capable of providing user input of a 6x6 stiffness matrix to represent the foundation stiffness at ground level. The stiffness matrix of a equivalent cantilever column can be expressed as:

751.9.2.8.2 k equiv.jpg

For translational and rotational stiffnesses, it is obvious that only three cantilever model parameters (i.e. EIy, EIz, and L) are not sufficient to satisfy all six stiffness coefficients (four diagonal stiffnesses, Ky, Kz, Kθy, Kθz, and two cross-coupling stiffness, Kyθz, Kzθy) in equation (1) of EPG 751.9.2.8.1.

However, the general approach is to match the diagonal stiffness terms Ky, Kz and Kθz. From eqs. (1) and (2):

751.9.2.8.2 general approach.jpg

Example 751.9.2.8.2:

Find the equivalent cantilever column’s L, EIy, EIz, EA and GJ in example 751.9.2.6.4.

Solve: From Example 751.9.2.6.4,

751.9.2.8.2 example.jpg
751.9.2.8.2 stiffness.jpg

751.9.2.9 Modeling of Pile (Drilled Shaft) Footings

751.9.2.9.1 Coupled Foundation Stiffness Method – Rigorous Approach

A rigorous approach to develop a linear 6 x 6 pile stiffness matrix at the bottom of the foundation cap has been described in Example 751.9.2.6.4 in EPG 751.9.2.6.4. Figure 751.9.2.9.1 illustrates the structural model used by this approach.

Fig. 751.9.2.9.1 Structural Model for Pile (and Drilled Shaft) Footing Bents

The common form of the stiffness matrix in the local pile (or shaft) coordinate system (xe, ye, ze) is given in eq. (1) in EPG 751.9.2.8.1.

751.9.2.9.2 Axial and Translational Stiffness Method - Simplified Approach

For a pile footing type configuration shown in Fig. 751.9.2.9.1, the rotational stiffness of the pile group tends to be dominated by the axial pile stiffness as compared to the stiffness contribution from the bending stiffness of individual piles. Therefore, a simplified fixed pile-head model can be used in the seismic analysis. Fig. 751.9.2.9.2 illustrates the pile footing model based on this approach. Only pile axial and two horizontal translational stiffnesses are considered in the analysis.

Fig. 751.9.2.9.2 Structural Model for Pile (and Drilled Shaft) Footing Bents

The stiffness matrix of a pile can be expressed as:

[Kpile]3x3 =

in which the diagonal terms Kx, Ky and Kz are stiffnesses corresponding to translational degrees of freedom associated with xe, ye and ze, respectively. Except for a special case, the simplified approach shall be considered sufficient in the seismic analysis.

751.9.2.10 Iterative Abutment Analysis

Soil Stiffness Nonlinearity

During an earthquake, ground motion causes the bridge abutments to impact against the soil, which deforms the soil. So, soil stiffness varies nonlinearly during seismic motion.

Linear Approximations of Nonlinear Soil Stiffnesses

By using response spectrum methods, an equivalent linear soil stiffness is required for proper modeling. Spring "constants" are not really constant, but instead they are changeable modeling tools. Equivalent linear springs are used to approximate nonlinear structure/soil interaction, similar to the "secant modulus" approximation for other nonlinear materials.

Reducing Stiffnesses

Fig. 751.9.2.10.1 is slightly altered from the AASHTO flowchart because of limits on reducing pile stiffnesses as described below.

Equivalent linear stiffnesses are valid only if they predict achievable soil forces. The passive force applied on the backwall will never exceed the passive force capacity of the soil, because the soil would fail before this could happen. If the seismic analysis program model is outputting an abutment force which exceeds the soil pressure capacity, then the model is predicting something impossible, and the spring constants must be reduced before accepting the model. According to AASHTO Div. I-A 1998 C4.5.2, this force-limiting should apply to all spring locations, including: 1) soil at backwall, 2) soil at wings, 3) piles, etc. Pile stiffness reduction is limited, as described below.

The starting values for springs should be based on the best available soil information, as described in EPG 751.9.2.6.4 and EPG 751.9.2.6.5, and it is better to slightly overestimate the stiffness than to underestimate it. Overestimated stiffnesses may be reduced to satisfy the displacement demand through iterative abutment analysis, usually iterative abutment analysis does not increase underestimated stiffnesses in order to save computing time.

Redesigning the Abutment for Force or Displacement

As indicated in the flowchart (Fig. 751.9.2.10.1) and the discussion of this section, the abutment may require redesigning if force or displacement limitations are exceeded. See EPG 751.9.2.10.1, EPG 751.9.2.10.2 or EPG 751.9.2.10.3 for discussion of intermediate wings, squared-off wings, deepened beams and other remedial actions.

Fig. 751.9.2.10.1 Flowchart for Iterative Abutment Analysis
"Sec. 6.1.2.10.2" refers to EPG 751.9.2.10.2.

General Procedure

Iterative Abutment Analysis
Note: Each different bridge model will require its own Iterative Abutment Analysis. For example, a model without liquefaction will require a completely independent analysis from a model with liquefaction.
1) Stiffness:
Compute the initial stiffness estimates as described in EPG 751.9.2.6.
2) RBT for Stiffness:
Combine the stiffnesses at the master joints using RBT as described in EPG 761.9.2.7.
3) Seismic Analysis:
Run the Seismic Structural Analysis Program as described in EPG 751.9.2.8.
4) RBT for Forces:
Redistribute the master joint forces using RBT for force as described in EPG 761.9.2.7.
5) Soil Pressures:
Compute the soil pressure (see EPG 751.9.2.10.1) on the backwall and the pressure on the wings. If the pressure is greater than the allowable pressure, then reduce the corresponding stiffness accordingly and go to Step 2. If the pressures are less than the allowable, then go to Step 6.
6) Pile Stresses:
a) Check shear stress and resultant moment (see EPG 751.9.2.10.2). If pile stress or moment is greater than the allowable, for simplicity, reduce the stiffnesses in each direction accordingly, corresponding to the pile-head displacement calculated in that direction. However, in order to keep R = 1 for pile foundations, do not reduce the stiffness below the minimum stiffness. The minimum stiffness is defined as the translational stiffness at which the ultimate moment, Mu, for concrete piles or plastic moment, Mp, for steel piles occurred along the pile as shown in Fig.751.9.2.10.2.
If the new stiffness is greater than the minimum stiffness, then go to Step 2.
If the new stiffness is less than the minimum stiffness, then go to Step 6 (b).
If the stress and moment are OK, then go to Step 7.
b) If pile stiffness has been reduced to the minimum, then the designer must do one of the following before going to Step 2:
i) For excessive transverse force, first add an intermediate wing (a maximum of two) and/or square off the exterior wings.
ii) For excessive longitudinal force, first try deepening the abutment beam by 6 in. min. - 12 in. max.
iii) If (i) and (ii) does't fix the problem, then try using a larger size pile or more piles and go to Step 2.
iv) As a last resort, if the abutment is still overloaded, try stiffening the intermediate bents by using larger columns or larger piles or more piles at the intermediate bents.
Fig. 751.9.2.10.2 Definition of Kmin
7) Abutment Displacements:
Check the displacements at the master joint (see EPG 751.9.2.10.3). If the abutment displacements are less than the allowable, then go to Step 8. If the abutment displacements are greater than the allowable, then the designer must do one of the following before going to Step 2:
i) Add abutment piles.
ii) Use larger size abutment piles.
iii) For excessive transverse displacement, add an intermediate wing (a maximum of two) and/or square off the exterior wings.
iv) For excessive longitudinal displacement, deepen the abutment beam by 6 in. min. - 12 in. max.
v) If the abutment is still overloaded, try stiffening the intermediate bents by using larger columns or larger piles or more piles at the intermediate bents.
vi) As a last resort, see the Structural Design Engineer about specifying the backfill soil properties.
8) Complete the Seismic Design:

Return to the checklist and/or flowchart in EPG 751.9.2.2 Checklist for Seismic Computations, then design abutment components, connections and intermediate bents as described in EPG 751.9.2.3 Minimum Support Length. If the seismic response of the bridge changes as a result of the design being different from the model assumed, then return to Step 2.

751.9.2.10.1 Soil Pressures, Backwall and Wings

Compacted Backfill Soil at Abutments

Ultimate soil capacities should be used for seismic design.

Additional Information
AASHTO Division I-A Sections 6.4.2(B) and 7.4.2(B)

It is not necessary to check resultant soil pressures. The longitudinal failure state of an abutment is taken to be when the ultimate soil pressure acts on the entire backwall, causing global failure of the sliding wedge of soil behind the backwall. The transverse failure state is taken to be when the ultimate soil pressure acts on the entire wing area, causing global failure of the sliding wedge of soil behind the wings. The actual distribution of stresses in compacted abutment fill is too complex to compute for cyclical seismic loads, and it is the global failure rather that a local failure that controls the ultimate capacity of the abutment soil. Therefore, check the backwall pressure normal to its plane, then check the wing pressure normal to its plane, considering them to be independent of each other.

p = F / A ≤ pA

p = pressure on the planar surface of the backwall or wing, ksf

F = Force on element obtained from Rigid Body Transformation (see EPG 761.9.2.7), kips. Check all seismic loading cases including both abutments and both load combinations:

Case I = 1.0*L + 0.3*T
Case II = 0.3*L + 1.0*T

A = Area of the backwall or wing, square feet

pA (for integral and non-integral abutments) = 7.7ksf = the maximum (ultimate) dynamic soil passive pressure, ksf. The maximum dynamic soil passive pressure, pA, shall be reduced for backwall heights less than 8 ft. For example: pA for a backwall height of 6 ft. pA = 7.7*(6/8) = 5.8 ksf.

If p > pA, then reduce the stiffness as described below and iterate until the pressure is just barely less than the allowable.

= trial stiffness for the i+1 run, kips/foot

δi = displacement of backwall or wing from the i run, ft.

Return to the checklist and/or flowchart in EPG 751.9.2.10 Iterative Abutment Analysis.

Additional Information
AASHTO Division I-A Sections 6.4.2(C) and 7.4.2(C)

751.9.2.10.2 Abutment Pile Stresses

Abutment Pile Stresses The allowable pile stress is the ultimate pile strength.

In order for the estimated pile stiffnesses to be valid, the pile stresses must be below the ultimate pile stress (i.e. R=1).

Additional Information
AASHTO Division I-A, 1992 Commentary C5.4.2

Non-Integral Abutments:

Consider non-integral abutment piles as "foundation" piles in AASHTO Div. IA, 7.2.1(B), with R=1, and do not allow plastic hinging.

Integral Abutments:

Use R=1 for ALL end bent piles, including those on integral end bents.

Concrete CIP Piles
1) Before running a seismic analysis program such as SEISAB, run one p-y curve program such as COM624P to obtain the stiffness and the lateral loadlateral displacement relationships as described in EPG 751.9.2.6.4.
2) After SEISAB & RBT have been run, rerun COM624P to obtain the moment demand (MR) due to the resultant applied lateral pile load, PR.
3) From the same or other COM624P programs, the resultant ultimate moment capacity, (Mu) can be obtained at the demand axial loads P = DL ± EQ. For seismic load Case I and Case II, check the following criteria:
MR ≤ Mu, where:
MR = maximum resultant moment demand at the demand axial load, P=DL ± EQ, and at the demand resultant lateral load, PR, ft.*kips
PR =, resultant applied lateral load, kips
Px or Py = applied lateral load at the pile-head from the RBT, in the longitudinal and transverse directions respectively, kips
Mu = ultimate moment capacity at the demand axial load, at P = DL ± EQ, and at a limit state of εc= 0.003 (concrete) or εs= 0.015 (steel).
If MR> Mu, then reduce the pile stiffnesses in both the long. and trans. directions according to the following equation:
Knew = or , where:
Knew = stiffness for new trial run, kips/ft., in the strong or weak directions.
Px’ and Py’ = pile-head lateral force on pile lateral load - lateral displacement curve as described in EPG 751.9.2.6.4 in the long. and trans. directions, respectively.
Hx and Hy = pile-head lateral displacements in the long. and trans. direction, respectively, from RBT.
4) Return to the checklist or flowchart of EPG 751.9.2.10.
Steel HP Piles
1) Before running a seismic analysis program such as SEISAB, run two p-y curve programs such as COM624P: one for the strong direction, and one for the weak direction to obtain pile lateral load – lateral displacement curves in the strong and weak directions.
2) After SEISAB & RBT have been run, rerun COM624P to obtain the maximum demand moments along the pile in the strong direction (Mx) and weak direction (My). To obtain Mx, run COM624P with the pile demand axial load, P = DL ± EQ and the pile lateral load in the strong direction (Px). To obtain My, run another COM624P with the pile demand axial load, P = DL ± EQ, and the pile lateral load in the weak direction (Py).
These two COM624P programs will have different pile section properties. Run both programs for load case I and load case II.
3) All piles must meet the following equation:
(1)
Additional Information
AASHTO 10.54.2
where:
P = applied axial load (DL ± EQ), kips
Mx and My = maximum moment demand at the above axial load, P, at the corresponding lateral load, Px or Py.
As = steel area, square inches
Fy = yield stress of steel, usually 36 ksi or 50 ksi. The difference in price is small, so 50 ksi should be used when steel stresses are high.
Mp = Z*Fy, where Z = plastic section modulus in the strong (x) or weak (y) direction, inch*kips
4) If eq. (1) can not be satisfied, then reduce the pile stiffness in both the strong and weak directions according to the following equation:
Knew = or , where:
Knew = stiffness for new trial run, kips/ft., in the strong or weak directions.
Px’ and Py’ = pile-head lateral force on pile lateral load - lateral displacement curve as described in EPG 751.9.2.6.4 in the long. and trans. directions, respectively.
Hx and Hy = pile-head lateral displacements in the long. and trans. direction, respectively, from RBT.
5) Return to the checklist or flowchart of EPG 751.9.2.10.

751.9.2.10.3 Abutment Deflection Iteration

Additional Information
AASHTO Division I-A, 1998 Commentary, C4.5.2

In Fig. 751.9.2.10.1, Flowchart for Iterative Abutment Analysis, after the abutment forces are OK, the resultant abutment displacement must also be acceptable before finishing the seismic analysis of the bridge.

where:
= resultant displacement of the master joint from the seismic analysis, ft.
, for Case I = L+0.3T
, for Case II = 0.3L+T
δR is at the master joint (see Fig. 751.9.2.10.3), using either CQC or SRSS.
δallowable = 0.3 ft., for integral abutments and non-integral abutments with restrainers engaged.
δallowable = 10*A (in inches) for non-integral abutments under active Mononobe - Okabe pressure, where A = Acceleration Coefficient in gs.
Additional Information
AASHTO Division I-A, 1998 Commentary

If the displacement exceeds the allowable value, then the abutment must be structurally altered as described in the flowchart description of EPG 751.9.2.10. If the structural behavior is different as a result of these changes, it will be necessary to redesign the bridge and the abutment for Group I-VI loads and for Seismic loads.

Fig. 751.9.2.10.3 Abutment Master Joint

751.9.3 Seismic Design Procedure

751.9.3.1 Connection Design

Seismic Performance Categories A, B, C, D

Seismic design forces can be considered either service loads or factored loads with a factor of 1.0. Load Factor Design (LFD) is to be used wherever possible. However, Allowable Stress Design (ASD) is still allowed when LFD would be difficult to apply. Connections must be designed for seismic forces in all four Seismic Performance Categories (A, B, C and D). For design of some typical seismic connections, see the EPG articles, below:

a) Anchor bolts (EPG 751.9.3.1.1)
b) Dowel bars (EPG 751.9.3.1.2)
c) Restrainer rods (EPG 751.9.3.1.3)
d) Concrete shear blocks (EPG 751.9.3.1.4)
e) Concrete end diaphragms (EPG 751.9.3.1.5)
f) Seismic isolation systems (EPG 751.9.3.1.6)
g) Joints (Beam/Column or Column/Footing) (EPG 751.9.3.1.7)
Additional Information
AASHTO Division I-A, Section 5.2

Seismic Performance Category A

Minimum horizontal design force in each restrained direction for connections in SPC A is as described in AASHTO Division I-A, Section 5.2.

A seismic analysis is not required in SPC A, so do not use R=0.8 in SPC A. Use R=1 instead.

Seismic Performance Categories B, C and D

Additional Information
AASHTO Division I-A, Sections 5.4, 5.5 and 5.6

For design of connections in SPC B, C and D, see AASHTO Division I-A, Sections 6.2.1 and 7.2.1(A). For design of column joint connections in SPC C and D, see AASHTO Division I-A, Section 7.6.4 and EPG 751.9.3.1.7.

751.9.3.1.1 Anchor Bolts

For LRFD, see EPG 751.11.2 Design for anchor bolt design.


751.9.3.1.2 Dowel Bars

For LRFD, see EPG 751.22.2.7 Dowel Bars for dowel bar design.


751.9.3.1.3 Restrainers

Most restrainer rods are low carbon steel (ASTM F1554, Fu = 58ksi, Fy = 36ksi) threaded rods at expansion gaps and hinges. They can be either longitudinal, transverse or vertical restrainers, depending on their axis of orientation. Restrainers are designed to remain elastic.

Longitudinal Restrainers

Longitudinal restrainers may be added at expansion gaps when predicted seismic displacements exceed the available support length. Restrainers should be added at all hinges with expansion gaps. Restrainers may also be added in other situations as discussed in a retrofit strategy meeting. Omit restrainers on exterior faces of exterior girders. Locate the restrainer group as close as possible to the center of gravity (c.g.) of the superstructure (see Fig. 751.9.3.1.3.3). Orient the restrainers parallel to the centerline of the superstructure, except for expansion joints on bridges with skew > 30° and all curved bridges, then consider orienting the restrainers normal to the joint. If the restrainer is connected to the bent cap, a higher force may be directed to the columns than otherwise expected, and the bent should be designed to withstand the restrainer force. See Figs. 751.9.3.1.3.3 – 751.9.3.1.3.9 for the details for Longitudinal Earthquake Restrainers for the different superstructure types.

Restrainer Rod Design:

Restrainer Capacity
Fcap = force capacity of restrainer in kips, the smaller of these forces:
At*Ft where:
At = tensile stress area of threaded rod, square inches
Ft = = allowable tensile stress = 1.5(0.33 Fu) = 1.5 x 0.33 x 58 = 28.7 ksi for F1554, grade 36 rod.
where:
DS = dead load of the entire superstructure unit, kips. When two segments are tied together, use the weight of the heavier segment.
n = the number of restrainers at the expansion gap
Restrainer Demand
Fdem= demand force in kips, taken to be the larger of these forces:
a) force from seismic analysis divided by the response factor, R,
where:
R = 1.0 for Seismic Performance Category A
R = 0.8 for Seismic Performance Categories B, C and D
b) 0.2*DS/n where:
DS = dead load of the entire superstructure unit, kips. When two segments are tied together, use the weight of the heavier segment.
n = the number of restrainers at the expansion gap
c) A*DL/n where:
A = Acceleration coefficient in gs
DL = the weight of the lighter of the two adjoining superstructure segments
n = the number of restrainers at the expansion gap
Example 9.3.1.3-1:
The accumulated dead load weight of a prestressed bridge segment with six girders is 1110 kips. The bridge is located in Seismic Performance Category C with A = 0.25. There are two 1 3/8 in. diameter restrainers for each girder at the end bent. From the seismic analysis, the total longitudinal force at the expansion gap is 300 kips. Check the suitability of the restrainers.
Solution:
Demand Force: 1) 0.2*DS/n = 0.2x1110/(2x6) = 18.5 kips
2) A*DS/n = 0.25x1110/(2x6) = 23.1 kips
3) (F/R)/n = (300/0.8)/12 = 31.25 kips ← Controls
Design Capacity: At*Ft = 1.48 x 28.71 ksi = 42.6 kips
42.6 kips > 31,25 kips Capacity is O.K.
∴ Two 1 3/8 in. diameter rods for each girder are satisfactory.
Note: Usually, restrainers should be omitted on the exterior face of exterior girders. For exterior girders, the two restrainers should be located on the interior face of the girder.

Anchor Stud Design

Anchor studs shall be designed using ultimate strength design and concrete shear cone failure theory. The standard stud size is 7/8” φ x 7” stud.

Use a response modification factor for connections of 0.8.

Locate the studs on the concrete backwall or diaphragm using the minimum spacing, 2R, and the minimum edge distance, R, where R is the major radius of the concrete shear cone as shown in Fig. 751.9.3.1.3.1, below. If the minimum spacing or minimum edge distance cannot be met, then see manufacturer's catalog for computation of partial cone strength reductions. If possible, center the stud group around the restrainer rod.

Fig. 751.9.3.1.3.1 Concrete Shear Cone for Anchor Stud

Anchor Plate Design

The area of the steel anchor plate shall be sized by the number of anchor studs required for tensile pullout and by the stud spacing (2R above) and edge distance on the plate. Locate the studs on the backwall or diaphragm using the minimum spacing, 2R, and the minimum edge distance, R. If the minimum spacing or minimum edge distance cannot be met, then consider the partial cone strength reductions. If possible, center the stud group around the restrainer rod. The thickness of the plate shall be sized by:

(a) Flexural stress on the plate considering the plate as a beam continuous-over-simple-supports with an allowable stress of 0.55Fy and a 33% allowable overstress in Seismic Performance Categories B, C and D,

Additional Information
AASHTO Division I-A, Sections 6.2.1 & 7.2.1 and AASHTO Table 10.32.1A

(b) Bearing stress on concrete (to account for the possibilities of local crushing at the expansion gap and/or restrainer deflection greater than 1/2" and/or backwall knockoff) of 0.3*f 'c, with a multiplier, , (where A1 is the loaded area and A2 is the maximum area of the portion of the supporting surface that is geometrically similar and concentric with the loaded area), plus a 33% allowable overstress in Seismic Performance Categories B, C and D. or

Additional Information
AASHTO Division I-A, Sections 6.2.1 & 7.2.1 and AASHTO 8.15.2.1.3

(c) minimum plate thickness = 3/8"

The backwall should be designed for flexure and shear as specified for abutment components in EPG 751.9.3.2.

Transverse Restrainers

Transverse restrainers are mainly used to keep the superstructure from sliding off the bearings. This type of restrainer is used either in place of, or along with, concrete shear blocks. The design procedure for transverse restrainers is the same as the design procedure for longitudinal restrainers with the exception that the demand force, Fdem, is only part a) of the longitudinal restrainer demand force design.

Vertical Restrainers (Hold-down Devices)

Vertical restrainers are only required in Seismic Performance Categories C and D (AASHTO Div. I-A, 7.2.5(B)), but they may also be used on important structures in SPC B. Vertical restrainers shall be used at all supports or hinges in continuous structures when the vertical seismic force (EQ) exceeds 50% of the dead load reaction (DR).

When 0.5(DR) < EQ < 1.0(DR), then the minimum net uplift force = 10% of the dead load downward force that would be exerted if the span were simply supported.

When EQ > 1.0(DR), then the net uplift force = 1.2*(EQ-DR), but not less than 10% of the dead load downward force that would be exerted if the span were simply supported.

Vertical restrainers can take several forms: (a) using existing anchor bolts, (b) adding threaded rods, (c) adding vertical restraining plates, or (d) adding prestressing strands. If vertical restrainers are required, see the Structural Project Manager to determine which vertical restrainer system should be used.


Fig. 751.9.3.1.3.2 Examples of Vertical Restrainers


(1) (Expansion Gap @ 60°F) + 1/2“
(2) Expansion Gap @ 60°F
(3) Design length as required for the weld to develop the seismic force.
(4) On skewed structures, adjust this distance parallel to the centerline of roadway.
(5) Locate the restrainer as close as possible to the neutral axis of the superstructure and as close as possible to the bottom of the diaphragm.
(6) End bent backwalls are to be designed for active seismic soil pressure as described in EPG 751.9.3.2.
(7) Omit restrainers on exterior faces of exterior girders.

Fig. 751.9.3.1.3.3 Longitudinal Restrainers (End Bents - Steel Girders)


Note: For skewed structures, see Figure 751.9.3.1.3.9.

(1) On skewed structures, adjust this distance parallel to the centerline of roadway.
(2) Locate at the center of gravity for the superstructure, using the spacing between girders.
If different beam depths are used, locate the restrainers at the neutral axis of the smaller beam. May adjust for clearance.
(3) Omit restrainers on exterior faces of exterior girders.
(4) End bent backwalls are to be designed for active seismic soil pressure as described in EPG 751.9.3.2.

Fig. 751.9.3.1.3.4 Longitudinal Restrainers (End Bents - Concrete Girders)


Note: For skewed structures, see Figure 751.9.3.1.3.9.
Yb = GRAVITY NEUTRAL AXIS OF PRESTRESSED I-GIRDERS *
ROADWAY GIRDER
SPACING
GIRDER TYPE
III IV VI VII
26'-0" 7’-6” 32.7 36.5 41.1 54.2
28’-0” 8’-2” 33.2 37.0 41.6 54.9
30’-0” 8’-8” 33.6 37.5 42.1 55.5
32’-0” 9’-2” 33.9 37.9 42.6 56.1
36’-0” 8’-2” 33.2 37.1 41.7 55.0
38’-0” 8’-8” 33.5 37.4 42.1 55.5
40’-0” 9’-0” 33.8 37.8 42.5 55.9
44’-0” 9’-9” 34.4 38.4 43.2 56.8

* Yb = Inches from bottom of beam, based on an 8½” slab.

(1) On skewed structures, adjust this distance parallel to the centerline of roadway.
(2) Locate at the center of gravity for the superstructure. Use the gravity neutral axis of the
composite section, using the spacing between girders. If different beam depths are used, locate
the restrainers at the neutral axis of the smaller beam. May adjust for clearance.
(3) Omit restrainers on exterior faces of exterior girders.

Fig. 751.9.3.1.3.5 Longitudinal Restrainers (Intermediate Bents - Concrete Girders)


(1) (Expansion Gap @ 60°F) + 1/2“
(2) Expansion Gap @ 60°F
(3) Design length as required for the weld to develop the seismic force.
(4) On skewed structures, adjust this distance parallel to the centerline of roadway.
(5) Locate the restrainer as close as possible to the neutral axis of the superstructure. Use the gravity neutral axis of the composite
section, using the spacing between girders. If different beam depths are used, locate the restrainers at the neutral axis of the smaller
beam. Adjust the restrainer to clear channel and shop weld. Larger bracing is required for prestressed to steel beam restrainers.
(6) Omit restrainers on exterior faces of exterior girders.

Fig. 751.9.3.1.3.6 Longitudinal Restrainers (Intermediate Bents - Steel to Concrete Girders)


(1) (Expansion Gap @ 60°F) + 1/2“
(2) Expansion Gap @ 60°F
(3) Design length as required for the weld to develop the seismic force.
(4) On skewed structures, adjust this distance parallel to the centerline of roadway.
(5) Locate the restrainer as close as possible to the neutral axis of the superstructure and as close as possible to the bottom of
the diaphragm. Use the gravity neutral axis of the girder, using the spacing between girders. If different beam depths are used,
locate the restrainers at the neutral axis of the smaller beam. Adjust the restrainer to clear channel and shop weld.
(6) Omit restrainers on exterior faces of exterior girders.

Fig. 751.9.3.1.3.7 Longitudinal Restrainers (Hinged Connection)


Note: Use Detail A for prestressed I-Girder structures at end and intermediate bents and also for all exterior
girders on inside face.

Use Detail B for steel structures at end bents or P/S I-Girders to steel structures at intermediate bents
or whenever more than two restrainers occupy one anchor plate.
Pull-out 32k per stud. Working stress load 16k per stud. (See TRW Nelson Division catalog.)

Fig. 751.9.3.1.3.8 Details A and B for Anchor Plates


* For dimension properties of pipe, see AISC Steel Construction Manual, Part 1.
(1) Design length as required for the weld to develop the seismic force.

Fig. 751.9.3.1.3.9 Details for Longitudinal Restrainers on Skewed Structures


751.9.3.1.4 Concrete Shear Blocks

For LRFD, see EPG 751.22.3.13 Concrete Shear Blocks for Concrete Shear Blocks design


751.9.3.1.5 Concrete End Diaphragms

Restrainers at Expansion Gaps, Concrete Girders

Design the concrete diaphragm thickness on P/S-I girder bridges with longitudinal restrainers at expansion gaps at abutments or intermediate bents. Check punching shear by Load Factor Design, as per AASHTO 8.16.6.6. Design force is the restrainer force used to size the rods in EPG 751.9.3.1.3. In tension, the failure surface is d/2 outside the outermost anchor studs.

751.9.3.1.6 Seismic Isolation Bearings

Isolation Bearings

Seismic isolation bearings shall conform to AASHTO Guide Specifications for Seismic Isolation Design, 3rd Ed., July 2010. Isolation bearings should only be used when specified on the design layout or when required for special retrofit projects. See the Structural Project Manager for approval and for the design specifications for the specific proprietary system to be used.

For LRFD, Seismic isolation bearings shall conform to AASHTO Guide Specifications for Seismic Isolation Design, 4th Ed., 2023.

751.9.3.1.7 T- Joint Connections

Principal Tension and Compression Stresses in Beam-Column Joints

The connections where columns and beams join, or where columns and footings join, should be based on the capacity design for shear and diagonal tension. For most locations, this is a “T”-shaped joint. For the analysis of “knee joints”, see Priestley and Seible, 1996.

Fig. 751.9.3.1.7.1 Joint Shear Stresses in a T-Joint

In the capacity design of connection joints, the column moment, M0, will be the moment that is known and which will correspond to flexural overstrength of the column plastic hinges, i.e. M0 = 1.3Mp of the column. If the columns are designed based on plastic hinging, the beam and footings shall be designed with capacities greater than or equal to 1.3Mp.

At each joint, the principal tension and compression stresses are defined and checked as follows:

(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
in which:
Vjh = Average horizontal shear force within a joint.
Vjv = Average vertical shear force within a joint.
vjh = Average horizontal shear stress within a joint.
vjv = Average vertical shear stress within a joint.
hb = Beam depth.
hc = Column diameter or rectangular column cross-section height.
bje = The effective width of a joint, defined in Fig. 751.9.3.1.7.2.
D = Round column diameter.
fv = Average vertical axial stress due to column axial force Pc, including the seismic component.
Pc = Column axial force.
fh = Average horizontal axial stress at the center of the joint.
pc = Nominal principal compression stress in a joint. (positive)
pt = Nominal principal tensile stress in a joint. (negative)
bb = Beam width
bc = Column cross-section width
Fig. 751.9.3.1.7.2 Effective Joint Width for Joint Shear Stress Calculations

In Fig. 751.9.3.1.7.2(c), the effective width is taken at the center of the column section, allowing a 45° spread from boundaries of the column section into the beam cap. In the transverse direction, the effective width will be the smaller of the value given by eq. (3) and the beam cap width bb. Experimental evidence indicates that diagonal cracking is initiated in the joint region when psi. The principle compression stress pc shall be limited to .

Design of Reinforcement for Beam-Column Joints

When the principal tension stress, pt, exceeds psi, joint cracking occurs and the following reinforcement shall be provided:

a) Vertical beam stirrup reinforcement shall be placed throughout the distance of hb/2 from the column face on each side of the column. The required amount of vertical beam stirrup reinforcement, Ajv, is:

(9)
Where:
Asc = The total area of longitudinal steel
yc = overstrength stress in the column reinforcement use
yc = 1.1f
fyv = yield stress of vertical stirrup reinforcement.

b) Vertical beam stirrup reinforcement within the joint, Avi, is

(10)

c) The additional beam bottom longitudinal reinforcement required is

(11)
where fyb = the yield stress of the beam bottom longitudinal reinforcement. This additional reinforcement must be carried a sufficient distance to develop its yield strength a distance hb/2 from the column face.

d) The horizontal hoop reinforcement within a joint requires

(12)

which for F = 0 simplifies to

(13)
Where
F = The beam cap prestress force.
fyh = The yield stress of the horizontal hoops.
La = The Anchorage length in the joint.

The minimum amount of horizontal hoop reinforcement shall be

(14)

The spacing of the horizontal hoop can be based on:

(15)

Where
As = The cross-sectional area of the hoop bar.
D’ = The hoop diameter.
Fig. 751.9.3.1.7.3 Beam Cap Joint Reinforcement

When the principal tension stress, pt, does not exceed psi, no joint cracking is expected. However, the following minimum reinforcement shall be provided:

a) Vertical beam stirrup reinforcement within the joint based on eq. (10)
b) Minimum horizontal hoop reinforcement based on eq. (14)

Note that the bending of any hooked reinforcement outward, away from the column core, shall not be used because it directs the anchorage force away from the joint. Inward bending of the column reinforcement is allowed. However, it is likely to cause a congestion problem. The use of straight column reinforcement embedded into the beam-column joint is recommended. The standard T-joint reinforcement details are shown in Figs. 751.9.3.1.7.4 - 751.9.3.1.7.6. If any reinforcement requirement based on eqs. (9) through (14) is greater than that shown in Figs. 751.9.3.1.7.4 - 751.9.3.1.7.6, the greater requirement shall be used.

Fig. 751.9.3.1.7.4 Int. Bent "T-Joint" Details
(1) Increase by 25% the development length (other than top bars) or the standard hook in tension “Ldh” of EPG 751.40.8.4.2.
(2) The spiral bars or wire shall be continued for a distance equal to ½ the column diameter but not less than 15” from the face of the column connection into the footing.
(3) Use the greatest length of the following: column diameter of 1/6 of the clear height of column. Lapping of spiral reinforcement in this region is not permitted.
(4) Splices may be eliminated when the column height is 20’-0” or less or restrictions do not practically allow for lap splices.


Fig. 751.9.3.1.7.5 Seismic Bar Details
Fig. 751.9.3.1.7.6 Beam - Footing "T-Joint" Details
See additional guidance in EPG 751.9.3.1.7, below, for footing reinforcement not shown.
(1) Increase by 25% the development length (other than top bars) or the standard hook minimum in tension “Ldh” of EPG 751.40.8.4.2.
(2) The spirals shall be continued for a distance equal to ½ the column diameter but not less than 15” from the face of the column connection into the footing.


Example 751.9.3.1.7.1: A column is subjected to an axial load (due to dead and seismic earthquake loads) of 520 kips. The column diameter is 36 in. with 20 #8 bars for longitudinal reinforcement. The beam cap dimensions are 3 ft. 9 in. wide by 3 ft. 7 in. deep with 5 #11 bars for the top reinforcement and 7 #10 bars for the bottom reinforcement as shown in Fig. 751.9.3.1.7.7. The column overstrength moment-axial load curve is shown in Fig. 751.9.3.1.7.8. Design the reinforcement details for the beam-column joint.

Fig. 751.9.3.1.7.7 Properties for Example Design
Fig. 751.9.3.1.7.8 Column Overstrength Interaction Diagram

Solution:

The axial load for the column = 520 kips.

From Fig. 751.9.3.1.7.8, M0 = 1562.6 k-ft.

From eq. (1): = 436.07 kips

From eq. (3): = 45 in.

From eq. (2): = 269.18 psi.

Vertical Axial Stress:

From eq. (6):

= 146.27 psi.

Horizontal Stress:

fh = 0 psi.

From eq. (7):

pc = 352.07 psi ≤ 0.3(3000 psi) = 900 psi O.K.

From eq. (8):

pt = -205.80 psi ≥ 3.5 3000 = 191.7 psi Not O.K.

Since pt is greater than , special joint reinforcement based on eqs. (9) through (14) are needed.

Check if moment capacity of the beam is greater than the overstrength moment capacity of the column.

Neglect the effect of the compression steel (conservative).

751.9.3.1.7.8 compression.jpg

Compare moment capacity of beam versus overstrength moment capacity of the column:

1669.39 k-ft. > 1562.60 k-ft.

Moment capacity of beam is greater than the overstrength moment capacity of the column. O.K.

Design of reinforcement for the beam-column joint

- Vertical reinforcement should be placed throughout a distance of hb/2 from the column face on each side of the column.
From eq.(9):
Asc = 15.70 in2
= 1.1f = 66 ksi.
fyv = 60 ksi.
Ajv = 0.125 (15.70) 66 / 60 = 2.16 in2
- Reinforcement within the joint confines:
From eq. (10):
= 0.0625 (15.70) 66 / 60 = 1.08 in2
- Additional bottom of beam longitudinal reinforcement:
From eq. (11):
= 0.0625 (15.70) 66 / 60 = 1.08 in2
This reinforcement must be developed at a distance hb/2 away from the face of the column.
- Hoop Reinforcement:
From eq. (13):
La = 40 in.
fyh = 60 ksi
∴use ρs
use #4 hoop reinforcement
As = 0.1963 in2
D’ = 36 – 2(2) – 4/8 = 31.5 in.
ρs = 0.003238
From eq. (15): = 7.70” spacing > 3” max. from Fig. 751.9.3.1.7.4. Therefore, Use S = 3”
Fig. 751.9.3.1.7.9 Summary of “T-Joint” Reinforcement

Principal Tension and Compression Stresses in Column-Footing Joints

Column – Footing joints are essentially the same as inverted beam-column T joints. Eqs. (1) through (8) are applicable to column-footing joints except the beam height, hb, shall be changed to the footing height, hf.

Design of Reinforcement for Column-Footing Joint

The design of the reinforcement for column-footing joints is similar to that for beam-column T joint. From a joint performance viewpoint, it is desirable to bend the column bars inward toward the joint by using 90° hook bars, but this will cause undue congestion. Bending column bars away from the joint will increase the diagonal tension stress within the joint region. However, it makes a stable platform for supporting the column cage and prevents congestion. When the column reinforcement is bent outward, eqs. (9) through (14) shall be applied. Since the column inelastic action may develop in directions other than parallel to one of the principal axes of the footing, the amount of vertical reinforcement in eq. (9) shall be placed in each of the four quadrant areas outside the joint. In other words, a total vertical stirrup area of:

(16)

shall be placed around the column.

Extra top reinforcement in the footing is also required in accordance with eq. (11). This reinforcement should pass through the column reinforcement or be placed as close as possible to the sides of the column and extend a distance of not less than l = 0.5*D + Ld, where Ld is the bar development length, beyond the face on both sides of the column.

Example 751.9.3.1.7.2: A column is subjected to an axial load (due to dead and seismic loads) of 520 kips. The column diameter is 36 in. with 20 #8 bars for longitudinal reinforcement. All column reinforcement is bent outward into the footing away from the joint. The footing depth is 39 inches. The top and bottom reinforcement for the footing is shown in Fig. 751.9.3.1.7.10, below. Design the reinforcement details for the column-footing joint.

Fig. 751.9.3.1.7.10 Details of Footing Reinforcement for Example 751.9.3.1.7.2

Solution:

751.9.3.1.7.10 solution.jpg

The axial load for the column = 520 kips.

From Fig. 751.9.3.1.7.8 in Example 751.9.3.1.7.1, M0 = 1562.6 k-ft.

From eq.(1): = 480.8 kips

From eq. (3):

From eq. (2): =262.39 psi.


Vertical Axial Stress:

From eq. (6):

= 136.21psi.

Horizontal Axial Stress:

fh = 0 psi.

Principal Stresses:

From eq. (7):

= 339.19 psi. ≤ 0.3(3000psi.) = 900 psi. O.K.

From eq. (8):

= -202.98 psi. > 3.5 = 191.7 psi. Not O.K.

Since pt is greater than allowed, special joint reinforcement based on eqs. (9)through (14) are needed.

Check moment capacity

Check the moment capacity of footing in the long direction to see if it is greater than the overstrength moment capacity of the column.

Neglect the effect of the compression reinforcement.

751.9.3.1.7.10 compression.jpg
Since Cc = T
= 2.0523"
Mn = As(fy)(d - a/2)
= 9.42(60)(35-(2.0523/2))
= 1600.17 k-ft.

Compare moment capacity of footing overstrength moment capacity of the column:

1600.17 k-ft > 1562.60 k-ft.

Moment capacity of the footing is greater than the overstrength moment of capacity of the column. O.K.

Check the moment capacity of the footing in the short direction to see if it is greater than the overstrength moment capacity of the column.

Neglect the effect of the compression reinforcement.

751.9.3.1.7.10 compression2.jpg
Since Cc = T
= 1.3207"
Mn = As(fy)(d - a/2)
= 9.43(60)(35-(1.3207/2))
= 1619.11 k-ft.

Compare moment capacity of footing overstrength moment capacity of the column:

1619.11 k-ft > 1562.60 k-ft.

Moment capacity of the footing is greater than the overstrength moment of capacity of the column. O.K.

Design of reinforcement for the column-footing joint

- Vertical reinforcement should be placed throughout a distance of hf/2 from the column face on each side of the column.
From eq. (16):
Asc = 15.71 in2
= 1.1 fy = 66 ksi.
fyv = 60 ksi.
Ajv = 0.5 (15.71) (66 / 60) = 8.641 in2
- Reinforcement within the joint confines:
From eqs. (9),(10) & (16):
= 0.25 (15.71)(66/60) = 4.320 in2
- Additional top of footing longitudinal reinforcement:
= 0.0625 (15.70)(66 / 60) = 1.08 in2
This reinforcement must be developed at a distance hb/2 away from the face of the column and must be placed so that the reinforcement goes through the column reinforcement. Asb is required in both directions in the footing.
- Hoop Reinforcement:
From eq. (13):
La = 35 in.
fyh = 60 ksi
= 0.004232
= 0.003195
ρs > ρs, min ∴use ρs
Use #5 hoop reinforcement
As = 0.3068
D’ = 36 - 2(2) - 5/8” = 31.375”
ρs = 0.004232
From eq. (15): = 9.24"
Use 9” Spacing
Note: By adding 3 in. to footing depth in this example problem, the principal tensile stress in the joint would have been less than the maximum allowed tensile stress, thus eliminating the need for the special joint reinforcement other than the minimum required reinforcement. However, the practice of increasing footing depth to eliminate the need for the special joint reinforcement should be limited to increasing the footing depth a maximum of 6 inches.
Fig. 751.9.3.1.7.11 Summary of Column-Footing Joint Reinforcement

751.9.3.1.8 Anchorage of Piles for Seismic B, C and D

For anchorage of piles for seismic categories B, C and D, see EPG 751.36.4 Anchorage of Piles for Seismic Categories B, C and D.

751.9.3.2 Abutment Component Design

After Iterative Abutment Design has shown that abutment forces and displacements are acceptable, and after connection design is completed, the abutment components may be designed.

Wings (Integral OR Non-Integral Abutments)

1) Design the wing thickness for the applied shear on the wing. The design section is where the corner brace meets the inside edge of the wing. Use φ = 1.0 for shear. It is sometimes satisfactory to treat wing walls as fuse elements (i.e., broken off elements). This is mainly for integral abutment on very wide structures where large forces are drawn to the abutment. In this case, a second analysis with reduced stiffness in the transverse direction is required. Divide the wing up into two sections of f'c = 3 ksi and f'c = 4 ksi. Soil pressure acts below the bottom of the approach slab. See EPG 751.40 LFD Widening and Repair.
2) Design the flexural steel in the inside face of the wing (minimum #6 - H - bars @ 8" cts.) for the applied wing moment. Moment = (wing Area)*(soil pressure)*(arm from edge of corner brace to c.g. of wing area). The design section is where the corner brace meets the inside edge of the wing. Use φ = 1.0 for flexure. Divide the wing up into two sections of f'c = 3 ksi and f'c = 4 ksi. Soil pressure acts below the bottom of the approach slab. Position the wing reinforcement so that it does not interfere with girders or piles. The top of intermediate wings shall clear the bottom of the approach slab by a minimum of 3". See EPG 751.40 LFD Widening and Repair.

Non-Integral Abutments

3) For non-integral abutments, check the stability under application of active soil pressure. Find the Mononobe-Okabe (combined seismic and nonseismic) pressure and the Rankine (non-seismic) pressure. For the stability and reinforcement computations for non-integral Abutment Design, the height of the soil force resultant could be obtained by assuming that the non-seismic resultant force by Rankine theory acts at H/3 from the bottom of the backwall, while the seismic resultant force should be taken to act at a height of 0.6H. H is defined as the height of the backwall. See AASHTO Div. I-A Commentary for a description of Mononobe-Okabe active seismic soil pressure computations.
4) Design non-integral bent backwalls for shear due to soil pressure on the fill face of the backwall. The design section is at the base of the backwall, just above the beam. Use φ = 0.85 for shear, as in AASHTO 8.16.6.
5) Design non-integral bent backwalls for flexure due to soil pressure on the cantilevered backwall. The design section is at the base of the backwall, just above the beam. Use φ = 0.90 for flexure in AASHTO 8.16.3.
6) Design the backwall for flexure with the restrainers engaged (in tension) on the cantilevered backwall. In general, the soil pressure on the backwall can be neglected because it will be tensile when the restrainers are in tension, due to the separating motion of the superstructure. The design section is at the base of the backwall, just above the beam. Use φ = 0.90 for flexure in AASHTO 8.16.3.
7) Design the thickness of the backwall when restrainer anchor plates are present. For two-way shear (AASHTO 8.16.6), the design section is a rectangle surrounding the anchor plate. The design of anchor studs for restrainer anchor plates is described in EPG 751.9.3.1.3.

Deadman Anchors

8) Design deadman anchors, if present, as in EPG 751.40 LFD Widening and Repair.

751.9.3.3 Intermediate Bent Design

751.9.3.3.1 Column/Footing Intermediate Bents

Analysis

1) From dynamic analysis, determine seismic (EQ) force and moment demands at top and bottom of columns. These full elastic (R=1) forces assume elastic response under seismic loads.

2) Determine dead load demands (DL) at top and bottom of columns.

3) Calculate magnified moment due to full elastic, , and modified elastic, , moments (including minimum moment from eccentricity) at top and bottom of columns. Second-order effects shall also be considered.

Elastic Design, Without Plastic Hinging

4) Check the column (the size and reinforcement required for Groups I-VI is the minimum size column) using the full elastic (R=1) moments from Step (3) and φ = 0.75 to 0.9, as per AASHTO 8.16.1.2. Calculate 8 cases at 8 axial loads (P3max, P3min, P4max, P4min, at both top and bottom of each column):

For LC 1.0*L + 0.3*T: a) P3max = DL + EQ, b) P3min = DL - EQ
For LC 0.3*L + 1.0*T: a) P4max = DL + EQ, b) P4min = DL - EQ

If the column requires only a few bars to be designed elastically, then add a few bars rather than design the column for plastic hinging.

If UP/AP ≥ 1.0 (Ultimate moment over Applied resultant moment), then skip to Step (7) for no plastic hinging. Else, if UP/AP < 1.0, then perform Steps (5) and (6) first, considering plastic hinging.

Plastic Design, With Hinging

5) If UP/AP < 1.0 in Step (4), then determine the column size and reinforcement required for modified elastic (R=5) moments using φ = 0.5 to 0.9 as per AASHTO Div. I-A, Section 7.6.2(B). The column design required for Groups I-VI loads is the minimum size. Generate the column P-M interaction capacity curve. Plot the 8 combinations of axial and modified elastic moment on the same graph. If all the points lie within the curve, then the design is sufficient. If not, add bars and re-plot the curve until all points barely lie within the curve.

6) Determine the overstrength (φ = 1.3) plastic moment capacities of the column sized in step (5) as per AASHTO Div. I-A, Section 7.2.2. Use any non-linear push-over analysis program to determine the column overstrength moment, 1.3Mp, at the bent failure mechanism stage. If a non-linear pushover analysis program is not available, any static analysis program can be used by designating the hinging locations at top and/or bottom of column, use a joint release, then apply the overstrength plastic moment as a joint load.

Column Shear

7) Check column shear reinforcement (spirals) as required in AASHTO Div. I-A, Section 6.6.2 & 7.6.2, which specifies the required reinforcement ratio.

= ratio of volume of provided spiral reinforcement to total volume of concrete core, no units

As= cross-sectional area of one leg of spiral, sq. in.

Dc= diameter of spiral, out-to-out, inches

db= bar diameter of spiral, inches

Ac= area of core, out-to-out of spirals, sq. in.

s = spiral pitch or spacing, inches

For computation of shear demand, consider the possibility that hinging could occur between the top of the footing and the mud line, instead of at the column/footing junction. This situation could occur on footings with large overburdens and soils with high SPT blow counts, which could cause a shorter effective column length and a larger column shear demand.

Footing Design

8) Design footings under Load Factor Design with φ = 0.90 for flexure and φ= 0.85 for shear, as per AASHTO 8.16.1.2.

  • Compare the moments from steps (4) and (6). If step (4) moments are lesser, then size the footings for the full elastic loads from step (4).

If step (6) moments are lesser, then size the footings for the overstrength plastic column moment capacities (Mop) from step (6) in all directions of possible hinging: a) In-plane hinging at its corresponding axial load, b) Outof-plane hinging at its corresponding axial load

  • For spread footing pressure, keep resultants in the middle 2/3 of the footing.
  • For the footing shear check, use Load Factor Design, with φ = 0.85.
  • For footing reinforcement design, use Load Factor Design, with φ = 0.90. For spread footings, design top steel for weight of footing + weight of soil. For pile footings, design the top of footing reinforcement for weight of footing + weight of soil + seismic pile

tension. Check pile requirements in AASHTO Division I-A, Section 6.4.2 or 7.4.2.

Beam Design

9) Design beams under Load Factor Design, with φ = 0.90 for flexure and φ = 0.85 for shear, as per AASHTO 8.16.1.2.

  • If the column design was OK (no hinging) under full elastic loads from Step (4), then consider dead loads and the seismic in-plane top-of-column shears and axial loads (for P-Δ effects) for the beam design.
  • If the column design was controlled by modified elastic loads (with plastic hinging) from Step (5), then consider dead loads and the overstrength (φ = 1.3) plastic moments from Step (6) for the beam design. In this case, designate the hinging location as a support, use

a joint release, then apply the overstrength plastic moment as a joint load.

  • For either elastic or plastic loads, design the beam for negative moments and for shear at faces of equivalent square columns, and design for maximum positive moments in between columns.

T-Joint Connection Design

10) Check the beam/column T-joint stresses and the column/footing T-joint stresses as described in EPG 751.9.3.1.7.

751.9.3.3.2 Pile Cap Intermediate Bents

Definitions of Terms

In AASHTO Div. I-A Sections 6 & 7, some AASHTO terms are different from MoDOT terms. AASHTO's "pile caps" are caps of pile footings or beam caps of pile bents, and are considered "foundations". AASHTO's "pile bents" are what MoDOT calls pile cap intermediate bents, and piles on pile bents are treated as columns, not as "foundations". MoDOT's CIP piles are considered in AASHTO both as "concrete-filled pipe piles" and as "Cast-in-Place concrete piles" with the shell considered as both longitudinal reinforcement and as shear reinforcement.

Additional Information
AASHTO LRFD Specs., 5.10.11.4.1c&d&e, 5.13.4.5, 5.13.4.6
AASHTO Division I, 4.5.17.4

For drilled shafts and piles, a plastic hinge developed above the ground line is allowed for trestle piles (at intermediate bents), but not for foundation piles (below the ground line). "Trestle" and "foundation" piles are as defined in EPG 751.40 LFD Widening and Repair.

Analysis of Bent

1) Model the bent according to EPG 751.9.2.8.1 or EPG 751.9.2.8.2.

2) From dynamic analysis, determine seismic (EQ) axial, moment and shear force demands of the piles. These full elastic (R=1) forces assume elastic response under seismic loads.

3) Determine dead load (DL) axial, moment and shear force demands of the piles.

Elastic Design, Without Hinging

4) The minimum pile size and reinforcement is that which was required for Groups I-VI. Check the minimum pile size using the full elastic (R=1) moments from Step (2) and φ = 0.75 to 0.9, as per AASHTO 8.16.1.2. Analyze the pile for axial / moment (P-M) interaction capacity for CIP piles. Steel piles are analyzed for buckling and for combined stresses as described in the AASHTO references.

Additional Information
AASHTO Div. I-A,7.5.2 & AASHTO Div. I, 10.36 & 10.54

Analyze the pile at 4 axial loads (P3max, P3min, P4max, and P4min):

For LC 1.0*L + 0.3*T: a) P3max = DL + EQ, b) P3min = DL - EQ
For LC 0.3*L + 1.0*T: a) P4max = DL + EQ, b) P4min = DL - EQ

The shell of CIP piles provides shear reinforcement and longitudinal flexural reinforcement (see equations below). See EPG 751.40 LFD Widening and Repair for the design thickness of the shell.

If UP/AP ≥ 1.0, or if UP/AP ≥ 1.0 by adding only a few bars, then skip to Step (8) for no hinging. Else, if UP/AP < 1.0 or if it takes too many added bars to increase UP/AP to more than 1.0, then perform Steps (5) or (6) first, considering plastic hinging.

Plastic Design, With Hinging

5) If UP/AP < 1.0 for pile above the ground line in Step (4), then determine the pile size and reinforcement required for modified elastic (R=3 for vertical piles only and R=2 for one or more battered piles) moments using φ = 0.5 to 0.9 as described in AASHTO Div. IA, Section 7.6.2(B). The pile design required for Groups I-VI loads should be the minimum design. Generate the pile P-M interaction curve. For steel HP piles, combined stresses are computed as described in EPG 751.9.2.10.2. Plot the 4 points of axial and modified elastic moment on the same graph. If all the points lie within the curve, then the design is sufficient. If not, add bars or use a larger pile size, and re-plot the capacity curve until all points barely lie within the curve. Use R=1 to design pile under the ground line.

6) If a non-linear push-over analysis program is available, determine the plastic hinge locations based on the horizontal bent displacements from the seismic analysis. If any plastic hinges occurred below the ground line, redesign the bent by increasing the total number of pile or pile size, etc.

7) The end regions of concrete piles should be reinforced for plastic hinging. Refer to Fig. 751.9.3.3.2 for the following terms.

A = the greater of (D/2 or 15")
B = the greater of (2*D or H/6 or 24")
D = the pile diameter, in inches
G = A + B = the length of the upper plastic hinging region, in inches
H = the pile clear height, from bottom of beam to mud line, inches
Fig. 751.9.3.3.2 C.I.P. Pile Plastic Hinge Region

AASHTO Div. I-A, 7.6.2(D) specifies the reinforcement ratio required, and the provided reinforcement ratio is given by:

Shells of CIP Piles:

Provided = the ratio of volume of reinforcement provided by

the shell to the total volume of the concrete core, no units.

Where: t = Shell thickness
D = Core Diameter

Spirals:

Provided = the ratio of volume of reinforcement provided by the spiral to the total volume of the concrete core, no units.
= cross-sectional area of one leg of spiral, sq. in.
Where: DC= diameter of spiral, out-to-out, inches
db= bar diameter of spiral, inches
Ac= area of core, out-to-out of spirals, sq. in.
s = spiral pitch or spacing, inches

Steel piles shall be provided with shear connector angles for anchorage.

Additional Information
AASHTO Div. I-A, 7.4.2(C) & Bridge Manual Section 3.72, 4.6 & 5.5

Beam Design

8) Design beams under Load Factor Design, with φ = 0.90. If the pile design was OK (no hinging) under full elastic loads from Step (4), then consider dead loads and the seismic in-plane top-of-column shears and axial loads (for P-Δ effects) for the beam design. If the column design was controlled by modified elastic loads (hinging) from Steps (5) or (6), then apply dead loads and the overstrength (φ = 1.3) plastic moments from Steps (5) or (6). For either elastic or plastic loads, design the beam for the negative moments at faces of equivalent square piles and for the maximum positive moments in between piles. Check shear in the beam at the faces of the equivalent square piles. Minimum beam width shall be as per EPG 751.40 LFD Widening and Repair, but should also provide 6 in. concrete cover outside piles as per AASHTO Div. I Section 4.5.15.2. Note that for 20 in. and 24 in. CIP piles, the standard 30 in. integral end bent beam width must be enlarged to 32 in. and 36 in., respectively.

T-Joint Connection Design

9) Check the beam/pile T-joint stresses as described in EPG 751.3.1.7.

751.9.3.3.3 Drilled Shaft Intermediate Bents

Drilled shafts (also called "Pedestal Piles") are described in EPG 751.40 LFD Widening and Repair. In the following discussion, the portion of the pedestal pile above ground will be referred to as the "column". The portion of the pedestal pile below ground will be referred to as the "shaft". Most drilled shafts have a shaft diameter larger than the column diameter, as shown below in Fig. 751.9.3.3.3. Drilled shafts are drilled or augered in, whereas piles are driven into place.

Fig. 751.9.3.3.3 Drilled Shaft (Pedestal Pile) Int. Bent

The following discussion of drilled shafts assumes that the pile diameter is larger than the column diameter. The column portion is allowed to plastic hinge, but the shaft portion is not allowed to hinge.

Sometimes, there is an enlarged bell at the bottom when required for bearing pressure. EPG 751.40 Widening and Repair (Noon-LRFD) allows this bell only in SPC A, but unusual situations might require a bell in other Seismic Performance Categories. If a bell is required in SPC B, C or D, then reinforcement should be provided around the outside of the bell, in order to prevent local crushing of the bell.

Drilled shafts with no bell are socketed into rock a minimum distance of 1.5 times the shaft diameter and are considered fixed at the rock line. Drilled shafts with a bell are considered pinned at the rock line.

Analysis of Bent

1) Model the bent according to Sections 6.1.2.8.1 and 6.1.2.8.2.

2) From the dynamic analysis, determine seismic (EQ) axial, moment and shear force demands at "top of column" (near the beam/column joint) and at "bottom of column" (near the column/shaft joint). These full elastic (R=1) forces assume elastic response under seismic loads.

3) Determine dead load (DL) axial, moment and shear force demands at "top of column" and at "bottom of column".

4) Plastic hinging of the column portion of a drilled shaft is allowed for trestle piles (intermediate bents), but not for foundation piles (end bents), as defined in EPG 751.40 LFD Widening and Repair. The shaft portion of a drilled shaft is considered a "foundation" in AASHTO Div. I-A, 7.2.1(B), so plastic hinging of the shaft portion of a drilled shaft is not allowed. Calculate the full elastic moments at all tenth-points of the entire column & shaft, and calculate the modified elastic moments at tenth-points of the column portion.

Column Design, Without Hinging

5) Check the column portion and shaft portion (the minimum size and reinforcement is that which was required for Groups I-VI) using the full elastic (R=1) moments from Step 5 and φ = 0.75 to 0.9, as per AASHTO 8.16.1.2. Analyze the column and shaft for axial / moment (P-M) interaction capacity. Analyze the column at 8 axial loads (P3max, P3min, P4max, and P4min, top and bottom):

For LC 1.0*L + 0.3*T, a) P3max = DL + EQ, b) P3min = DL - EQ
For LC 0.3*L + 1.0*T, a) P4max = DL + EQ, b) P4min = DL - EQ

If UP/AP ≥ 1.0 or if UP/AP ≥ 1.0 by adding only a few bars, then skip to Step (8) for no hinging. Else, if UP/AP < 1.0 or if too many bars must be added, then perform Steps (6) and (7) first, for column plastic hinging.

Plastic Column Design, With Hinging

6) If UP/AP < 1.0 in Step (4), then the column portion is designed for modified elastic moments (R=5), and the shaft portion is designed as a foundation (R=1). Determine the column size and reinforcement required for modified elastic (R=5) moments using φ = 0.5 to 0.9 as described in AASHTO Div. I-A, Section 7.6.2(B), with the column design required for Groups I-VI loads as the minimum. Generate the column P-M interaction curve for drilled shafts. Plot the combinations (as in Step (5) above) of axial and modified elastic moment on the same graph for all 8 points on the column portion. If all the points lie within the curve, then the column design is sufficient. If not, add bars and re-plot the capacity curve until all points barely lie within the curve.

Additional Information
AASHTO Div. I-A, 7.2.2(B), Step 2

7) The end regions of columns should be reinforced for plastic hinging. The end region length at either end of the column is the larger of (two times the column diameter, one-sixth of the clear height of the column, and 24 inches). The spiral at the bottom end of the column shall continue into the shaft for a distance equal to the greater of (half the column diameter or 15 inches).

Design column shear reinforcement (spirals) for the required reinforcement ratio described in the reference below.

Additional Information
AASHTO Div. I-A, Section 7.4.2 & 7.6.2

For the provided reinforcement ratio of spirals:

Provided = the ratio of volume of provided spiral reinforcement to total volume of concrete core, no units.

Where:

As= cross-sectional area of one leg of spiral, sq. in.
Dc= diameter of spiral, out-to-out, inches
db= bar diameter of spiral, inches
Ac= area of core, out-to-out of spirals, sq. in.
s = spiral pitch or spacing, inches

Shaft Design

8) The design moments for the shaft shall be the lesser of the full elastic moments (R=1) from Step (5) and the overstrength plastic moment capacity (φ = 1.3) of the column sized in step (6).

Additional Information
AASHTO Div. I-A, Section 7.2.1(B) & 7.2.2 & 7.2.6

Beam Design

9) Design the beam under Load Factor Design, with a flexural φ = 0.90 and a shear φ = 0.85. If the column design was OK (no hinging) under full elastic loads from Step (5), then apply dead loads and the seismic in-plane top-of-column shears and axial loads for the beam design. If the column design was controlled by modified elastic loads (hinging) from Step (6), then apply dead loads and the overstrength (φ = 1.3) plastic moments from Step (6). For either elastic or plastic loads, design the beam for the negative moments at faces of equivalent square columns and for the maximum positive moments in between columns. Check shear in beams according to hinging or no hinging.

T-Joint Connection Design

10) Check the beam/column T-joint stresses as described in EPG 751.9.3.1.7.

751.9.3.3.4 Integral Intermediate Bents

The difference between a standard intermediate bent and an integral intermediate bent is shown in Fig. 751.9.3.3.4.

Fig. 751.9.3.3.4 Difference Between Standard and Integral Diaphragms

On standard intermediate bents, the beam stirrups are completely contained within the beam, and a line of dowels creates only a "pinned" connection with the diaphragm and superstructure. Due to the roofing felt and the dowels, the "pinned" connection theoretically does not transfer moments between the superstructure and the substructure. A standard (non-integral) intermediate bent therefore exhibits single-curvature bending out of the plane of the bent. In-plane bending is double-curvature due to the moment connections between beam and columns or between beam and piles.

On an integral intermediate bent (non-standard), the beam stirrups extend up into the diaphragm (similar to standard integral end bents), making a "fixed" connection which can transfer moments between the superstructure and the substructure. This fixed connection makes the integral intermediate bent exhibit double-curvature bending out of the plane of the bent. In-plane bending is also double-curvature due to the moment connections between beam and columns or beam and piles.

When to Use Integral Intermediate Bents

1) When (KL)/R > 100 for piles or drilled shafts and a larger diameter member is not acceptable. This situation can be improved by making the intermediate bent integral, causing double-curvature out-of-plane bending (K = 1.2) instead of single-curvature out-of-plane bending (K = 2.0), thus reducing (KL)/R.

2) When the percentage of the total seismic force at the end bents is so high that other remedial actions are ineffective (see EPG 751.9.2.10). This situation can be improved by making the intermediate bents integral, which makes them stiffer and helps to distribute some of the excessive force from the end bents to the intermediate bents.

3) Sometimes, making the bent integral can help to stiffen up the entire bridge, decrease the period, and may improve the situation.

751.9.3.4 Cross Frame Analysis and Design

Recent earthquakes indicate that many steel bridges have suffered cross frame damage. Cross frames provide an important load path for the seismic force acting on slab-on-girder steel bridges. Cross frames shall be able to transmit all lateral forces from the superstructure to the bearings. The lateral seismic force at an individual bent calculated from the seismic analysis shall be proportionally distributed to the individual cross frames over the bent.

For details of cross frames, see EPG 751.40 LFD Widening and Repair. The components of cross frames including top and bottom chords and diagonal angle members shall be designed based on allowable stress design with consideration of the eccentric axial load and buckling stresses. Welding sizes at gusset plate connection shall also be designed for the seismic load. Cross frames shall remain elastic when subjected to the seismic force.

The following cross frame model may be used for the structural analysis of cross frames:

Fig. 751.9.3.4.1 Cross Frame Model (S.M. Zahrai & M. Bruneau, 1999)

Study (S.M. Zahrai and M. Bruneau, 1999) has shown that bearing stiffeners provide the main stiffness for girders; in other words, using a longer length of girder (greater than 20 inches) in the model in Fig. 751.9.3.4.1 results in no significant difference in model stiffness. Based on the cross frame model in Fig. 751.9.3.4.1, the following structural analysis model can be considered:

Fig. 751.9.3.4.2 Structural Model for Cross Frames

In Fig. 751.9.3.4.2, Iy = moment of inertia of the stiffened stub girder (mainly due to the bearing stiffeners) in the lateral direction (i.e. y-y direction). The above model assumes full fixity at the concrete deck and zero fixity at the flexible bearings such as elastomeric bearings.

751.9.4 References

Cheney, R.S., and Chassie, R.G. (1982), “Soils and Foundation Workshop Manual,” U.S. Department of Transportation, Federal Highway Administration.

FHWA, “ Seismic Retrofitting Manual for Highway Bridges,” FHWA-RD-94-052, May 1995.

Kavazanjian, E. Jr., Matasovic, N., Hadj-Hamou, T., and Sabatini, P.J., “Geotechnical Engineering Circular No. 3, Design Guidance: Geotechnical Earthquake Engineering for Highways,” Volume 1- Design Principles, FHWASA- 97-076, 1997.

Lam, I.P., Kapnskan, M., and Chandhuri, D., “Modeling of Pile Footings and Drilled Shafts for Seismic Design,” MCEER Report 98-0018, 1998.

Lam, I.P., and Martin, G.R., “Seismic Design of Highway Bridge Foundations,” Federal Highway Adminstration Report # RD-86-101, 102, 103, 1986.

Lambe, T.W., and Whitman, R.V. (1969), Soil Mechanics, John Wiley and Sons, Inc., New York.

Meyerhof, G.G.(1976), “Bearing Capacity and Settlement of Pile Foundations,” Journal of Geotechnical Engineering Division, ASCE, Volume 102, No. GT3, Proc. Paper 11962.

NHI Course No. 13063, “Seismic Bridge Design Applications,” Session 6, 1996.

Norlund, R.L. (1963), “Bearing Capacity of Piles in Cohesionless Soils,” ASCE, SM&F Journal SM-3.

Norlund, R.L. (1979), “Point Bearing and Shaft Friction of Piles in Sand,” 5th Annual Fundamentals of Deep Foundation Design, University of Missouri-Rolla.

Priestley, M.J.N., and Seible, F., (1996) Seismic Design and Retrofit of Bridges, John Wiley and Sons.

Thurman, A.G. (1964), “Computed Load Capacity and Movement of Friction and End-Bearing Piles Embedded in Uniform Stratified Soil,” Ph.D. Thesis, Carnegie Institute of Technology.

Tomlinson, M.J. (1985), “Foundation Design and Construction,” Longman Scientific and Technical, Essex, England.

United States Steel (1965), Highway Structures Design Handbook, Volume 1, Chapter 10.

Urzua, A. (1993), SPILE: A Microcomputer Program for Determining Ultimate Vertical Static Pile Capacity, User’s Manual, FHWA-SA-92-044.

Wang, S.C., and Reese, L.C. (1993), COM624P- Laterally Loaded Pile Analysis Program for the Microcomputer, FHWA-SA-91-048.

Wilson, J.C. (1988), Stiffness of Non-Skew Monlithic Bridge Abutments for Seismic Analysis, Journal of Earthquake Engineering and Structural Dynamics Vol. 16.

Zahrai, S.M., and Bruneau, M. (1999) Ductile End-Diaphragms for Seismic Retrofit of Slab-on-Girder Steel Bridges, Journal of Structural Engineering, ASCE, Volume 125, No. 1.