Difference between revisions of "751.32 Concrete Pile Cap Intermediate Bents"
Jump to navigation
Jump to search
(Change minimum distance from 9" to 8" from outside edge of pile to face of beam on concrete pile cap integral and non-integral end bents, intermediate pile cap bents, semi-deep abutment beam caps.) |
m (Typographical corrections.) |
||
Line 103: | Line 103: | ||
|[[Image:751.32 details-part elevation.gif]]||[[Image:751.32 details-part section.gif]] | |[[Image:751.32 details-part elevation.gif]]||[[Image:751.32 details-part section.gif]] | ||
|- | |- | ||
− | |colspan="2" | * 3" (Typ.) | + | |colspan="2" | (*) 3" (Typ.) |
|- | |- | ||
!Part Elevation||Part Section | !Part Elevation||Part Section | ||
Line 122: | Line 122: | ||
|- | |- | ||
|valign="top"|[[Image:751.32 circled 5.gif]] | |valign="top"|[[Image:751.32 circled 5.gif]] | ||
− | |width="500" align="left"|Use 3/4" bevel strip if expansion device is located at bent. Continue to use 1 1/2" clear to reinforcing steel in bottom of beam. | + | |width="500" align="left"|Use 3/4" bevel strip if expansion device is located at bent. Continue to use 1-1/2" clear to reinforcing steel in bottom of beam. |
|- | |- | ||
|valign="top"|[[Image:751.32 circled 6.gif]] | |valign="top"|[[Image:751.32 circled 6.gif]] |
Revision as of 11:31, 30 September 2009
Contents
751.32.1 General
751.32.1.1 Material Properties
Concrete | |||
---|---|---|---|
Typically, shall consist of: | |||
Class B Concrete (Substructure) | = 3.0 ksi | ||
= 10 |
In addition, Class B-1 Concrete (Substructure) may also be used in special cases (See Project Manager). The following equations shall apply to both concrete classes:
Concrete modulus of elasticity:
Where:
= unit weight of non-reinforced concrete = 0.145 kcf | |
= correction factor for source of aggregate = 1.0 |
Modulus of Rupture: | For minimum reinforcement, | |
For all other calculations, | ||
is in units of ksi |
Reinforcing Steel
Minimum yield strength, | = 60.0 ksi | |
Steel modulus of elasticity, | = 29000 ksi |
751.32.2 Design
751.32.2.1 Limit States and Factors
In general, each component shall satisfy the following equation:
Where:
= Total factored force effect | |
= Force effect | |
= Load modifier | |
= Load factor | |
= Resistance factor | |
= Nominal resistance | |
= Factored resistance |
Limit States
The following limit states shall be considered for bent design:
- STRENGTH – I
- STRENGTH – III
- STRENGTH – IV
- STRENGTH – V
- SERVICE – I
- FATIGUE
See LRFD Table 3.4.1-1 and LRFD 3.4.2 for Loads and Load Factors applied at each given limit state.
Resistance factors
- STRENGTH limit states, see LRFD 5.5.4.2
- For all other limit states, = 1.00
751.32.3 Details
751.32.3.1 General
(*) 3" (Typ.) | |
Part Elevation | Part Section |
---|
751.32.3.2 Front Sheet
Note: | The following are details and dimensions for the Plan View on the Front Sheets. |
Details for unsymmetrical roadways will require dimensions tying Centerline Lane to Centerline Structure. |
751.32.4 Reinforcement
751.32.4.1 General
Part Elevation | Section Thru Beam |
---|---|
Part Plan |
* #4 Bars () not required for Double-Tee structures | |
Reinforcement Under Bearings | |
---|---|
Transverse Beam Steps - Over 3" or Steps Accumulating Over 3" |
Part Plan | |
---|---|
Over 3" thru 12" | Over 12" |
Longitudinal Beam Steps |