Difference between revisions of "751.32 Concrete Pile Cap Intermediate Bents"
Jump to navigation
Jump to search
m (Typographical corrections.) |
m (Clarification of drip groove to indicate correct formation.) |
||
Line 122: | Line 122: | ||
|- | |- | ||
|valign="top"|[[Image:751.32 circled 5.gif]] | |valign="top"|[[Image:751.32 circled 5.gif]] | ||
− | |width="500" align="left"|Use 3/4" | + | |width="500" align="left"|Use 3/4" drip groove where expansion device is located at bent. Continue to use 1-1/2" clear to reinforcing steel in bottom of beam. 3/4" drip groove shall be formed continuously around all piling at 3" from edge of beam. |
|- | |- | ||
|valign="top"|[[Image:751.32 circled 6.gif]] | |valign="top"|[[Image:751.32 circled 6.gif]] |
Revision as of 11:20, 25 November 2009
Contents
751.32.1 General
751.32.1.1 Material Properties
Concrete | |||
---|---|---|---|
Typically, shall consist of: | |||
Class B Concrete (Substructure) | = 3.0 ksi | ||
= 10 |
In addition, Class B-1 Concrete (Substructure) may also be used in special cases (See Project Manager). The following equations shall apply to both concrete classes:
Concrete modulus of elasticity:
Where:
= unit weight of non-reinforced concrete = 0.145 kcf | |
= correction factor for source of aggregate = 1.0 |
Modulus of Rupture: | For minimum reinforcement, | |
For all other calculations, | ||
is in units of ksi |
Reinforcing Steel
Minimum yield strength, | = 60.0 ksi | |
Steel modulus of elasticity, | = 29000 ksi |
751.32.2 Design
751.32.2.1 Limit States and Factors
In general, each component shall satisfy the following equation:
Where:
= Total factored force effect | |
= Force effect | |
= Load modifier | |
= Load factor | |
= Resistance factor | |
= Nominal resistance | |
= Factored resistance |
Limit States
The following limit states shall be considered for bent design:
- STRENGTH – I
- STRENGTH – III
- STRENGTH – IV
- STRENGTH – V
- SERVICE – I
- FATIGUE
See LRFD Table 3.4.1-1 and LRFD 3.4.2 for Loads and Load Factors applied at each given limit state.
Resistance factors
- STRENGTH limit states, see LRFD 5.5.4.2
- For all other limit states, = 1.00
751.32.3 Details
751.32.3.1 General
(*) 3" (Typ.) | |
Part Elevation | Part Section |
---|
751.32.3.2 Front Sheet
Note: | The following are details and dimensions for the Plan View on the Front Sheets. |
Details for unsymmetrical roadways will require dimensions tying Centerline Lane to Centerline Structure. |
751.32.4 Reinforcement
751.32.4.1 General
Part Elevation | Section Thru Beam |
---|---|
Part Plan |
* #4 Bars () not required for Double-Tee structures | |
Reinforcement Under Bearings | |
---|---|
Transverse Beam Steps - Over 3" or Steps Accumulating Over 3" |
Part Plan | |
---|---|
Over 3" thru 12" | Over 12" |
Longitudinal Beam Steps |