User contributions
Jump to navigation
Jump to search
This user is currently blocked. The latest block log entry is provided below for reference:
- 10:22, 23 September 2021 diff hist +35 m Recent Policy Changes in the EPG EPG 616.6.37
- 14:43, 22 September 2021 diff hist +4 m 616.6 Temporary Traffic Control Zone Devices (MUTCD 6F) →616.6.37 Shoulder Work Signs (WO21-5b) (MUTCD 6F.37)
- 13:02, 22 September 2021 diff hist 0 m 616.6 Temporary Traffic Control Zone Devices (MUTCD 6F) →616.6.37 Shoulder Work Signs (WO21-5b) (MUTCD 6F.37)
- 12:58, 22 September 2021 diff hist 0 N File:WO21-5b 2021.jpg current
- 12:57, 22 September 2021 diff hist 0 N File:WO21-5a.jpg current
- 12:57, 22 September 2021 diff hist 0 N File:WO21-5 Ahead.jpg current
- 12:57, 22 September 2021 diff hist 0 N File:WO21-5 Shoulder Work.jpg current
- 12:57, 22 September 2021 diff hist +523 m 616.6 Temporary Traffic Control Zone Devices (MUTCD 6F) →616.6.37 Shoulder Work Signs (WO21-5b) (MUTCD 6F.37): Per TS, SHOULDER WORK, SHOULDER WORK AHEAD, and RIGHT/LEFT SHOULDER CLOSED signs updated to match MUTCD guidance and EPG typical applications of shoulder work.
- 08:10, 20 September 2021 diff hist 0 N File:751.22.3.6 wwr6 table 2021.jpg current
- 08:06, 20 September 2021 diff hist 0 N File:751.22.3.6 wwr6 2021.jpg current
- 08:04, 20 September 2021 diff hist 0 N File:751.22.3.6 welded alternate 2021.jpg current
- 08:02, 20 September 2021 diff hist +15 m 751.22 Prestressed Concrete I Girders →751.22.3.4.3 Anchorage Zone Reinforcement: Per BR, revised increments for legs of shaped bars from ⅛” to ¼” due to upcoming move to new bill of reinforcing steel software which does not allow ⅛” increments. Revised various EPG details that showed ⅛” increments.
- 07:59, 20 September 2021 diff hist -102 m 751.21 Prestressed Concrete Slab and Box Beams →751.21.3.10 Exterior Beam Bevel at Slab Edge and Drip Bevel: Per BR, revised increments for legs of shaped bars from ⅛” to ¼” due to upcoming move to new bill of reinforcing steel software which does not allow ⅛” increments. Revised various EPG details that showed ⅛” increments.
- 07:53, 20 September 2021 diff hist 0 m 751.12 Barriers, Railings, Curbs and Fences →751.12.1.4.3 End of Barrier Reinforcement
- 07:52, 20 September 2021 diff hist 0 N File:751.12.1.4.3.2 Sep 2021.jpg current
- 07:52, 20 September 2021 diff hist +4 m 751.12 Barriers, Railings, Curbs and Fences →751.12.1.4.3 End of Barrier Reinforcement: Per BR, included previously inadvertently excluded info
- 11:24, 17 September 2021 diff hist -2 m 751.21 Prestressed Concrete Slab and Box Beams →751.21.3.3.1 Spread Box Beams
- 11:22, 17 September 2021 diff hist 0 N File:751.21.3.10 2021.jpg current
- 11:22, 17 September 2021 diff hist 0 N File:751.21.3.3.1 bending3 2021.jpg current
- 11:21, 17 September 2021 diff hist 0 N File:751.21.3.3.1 bending2 2021.jpg current
- 11:21, 17 September 2021 diff hist 0 N File:751.21.3.3.1 bending1 2021.jpg current
- 11:20, 17 September 2021 diff hist +20 m 751.21 Prestressed Concrete Slab and Box Beams Per BR, revised increments for legs of shaped bars from ⅛” to ¼” due to upcoming move to new bill of reinforcing steel software which does not allow ⅛” increments. Also revised various EPG details that showed ⅛” increments.
- 11:18, 17 September 2021 diff hist 0 N File:751.13.6.5 bending 2021.jpg current
- 11:18, 17 September 2021 diff hist 0 m 751.13 Expansion Joint Systems Per BR, revised increments for legs of shaped bars from ⅛” to ¼” due to upcoming move to new bill of reinforcing steel software which does not allow ⅛” increments. Revised various EPG details that showed ⅛” increments.
- 11:13, 17 September 2021 diff hist 0 N File:751.12.1.6.1 2021.jpg current
- 11:13, 17 September 2021 diff hist 0 N File:751.12.1.6 2021.jpg current
- 11:13, 17 September 2021 diff hist 0 N File:751.12.1.5.2 2021.jpg current
- 11:12, 17 September 2021 diff hist 0 N File:751.12.1.4.3.6 2021.jpg current
- 11:12, 17 September 2021 diff hist 0 N File:751.12.1.4.3.5 2021.jpg current
- 11:12, 17 September 2021 diff hist 0 N File:751.12.1.4.3.4 2021.jpg current
- 11:11, 17 September 2021 diff hist 0 N File:751.12.1.4.3.3 2021.jpg current
- 11:11, 17 September 2021 diff hist 0 N File:751.12.1.4.3.2 2021.jpg current
- 11:11, 17 September 2021 diff hist 0 N File:751.12.1.4.3.1 2021.jpg current
- 11:10, 17 September 2021 diff hist 0 N File:751.12.1.4.2 2021.jpg current
- 11:10, 17 September 2021 diff hist 0 N File:751.12.1.3.3.8 2021.jpg current
- 11:09, 17 September 2021 diff hist 0 N File:751.12.1.3.3.7.2 2021.jpg current
- 11:09, 17 September 2021 diff hist 0 N File:751.12.1.3.3.7.1 2021.jpg current
- 11:09, 17 September 2021 diff hist 0 N File:751.12.1.3.3.6 2021.jpg current
- 11:09, 17 September 2021 diff hist 0 N File:751.12.1.3.3.5.2 2021.jpg current
- 11:08, 17 September 2021 diff hist 0 N File:751.12.1.3.3.5.1 2021.jpg current
- 11:08, 17 September 2021 diff hist 0 N File:751.12.1.3.3.4.2 2021.jpg current
- 11:08, 17 September 2021 diff hist 0 N File:751.12.1.3.3.4.1 2021.jpg current
- 11:07, 17 September 2021 diff hist 0 N File:751.12.1.3.3.3.2 2021.jpg current
- 11:07, 17 September 2021 diff hist 0 N File:751.12.1.3.3.3.1 2021.jpg current
- 11:06, 17 September 2021 diff hist 0 N File:751.12.1.3.3.2.2 2021.jpg current
- 11:06, 17 September 2021 diff hist 0 N File:751.12.1.3.3.2.1 2021.jpg current
- 11:05, 17 September 2021 diff hist 0 N File:751.12.1.3.3.1.2 2021.jpg current
- 11:05, 17 September 2021 diff hist 0 N File:751.12.1.3.3.1.1 2021.jpg current
- 11:05, 17 September 2021 diff hist 0 N File:751.12.1.3.2 2021.jpg current
- 11:04, 17 September 2021 diff hist +171 m 751.12 Barriers, Railings, Curbs and Fences Per BR, revised increments for legs of shaped bars from ⅛” to ¼” due to upcoming move to new bill of reinforcing steel software which does not allow ⅛” increments. Also revised various EPG details that showed ⅛” increments.